{"bekendtgoerelseNoegle":{"noticeId":{"value":"ecf233c2-3a70-4d48-9767-5d1a18a83e53"},"noticeVersion":{"value":"01"},"noticePublicationNumber":{"value":"00209494-2026"}},"htmlDA":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Køber</span><section>1.1&nbsp;<span class=\"label\">Køber</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Køberens retlige status</span><span class=\"text\">: </span><span class=\"dynamic-label\">Offentligretligt organ</span></section>\n            <section><span class=\"label\">Den ordregivende myndigheds aktivitet</span><span class=\"text\">: </span><span class=\"dynamic-label\">Uddannelse</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU Sustain is working with environmental forensics and metabolomic investigations\n                  to study the fate and occurrence of chemicals and small molecules dispersed into the\n                  environment. <br/><br/>To be able to make these investigations, DTU wants to procure\n                  a low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform,\n                  capable of characterizing small molecules with collisional dissociation and laser-based\n                  ultraviolet-photodissociation (UVPD) for multi-stage molecular fragmentation (MSn)\n                  in liquid chromatography time scale. The mass spectrometer platform must have two\n                  independent mass detectors, and capable of resolving very complex molecular mixtures\n                  to improve unknown chemical characterization with fine isotope detection at one million\n                  in mass resolution (at mass-to-charge 200) or higher. The liquid chromatography system\n                  must be able to make chromatographic separations of complex mixtures at low-flow conditions\n                  (10-100 nano-liters per minute) and seamlessly integrated with nanoelectrospray ionization\n                  and controlled, jointly with themass spectrometer, within the same software environment.<br/><br/>In\n                  addition, the combined system must have;<br/>• Two atmospheric pressure ionisation\n                  interfaces; heated electrospray ionisation (HESI) and<br/>nano-spray ionisation (NSI).<br/>•\n                  A nanoflow UHPLC (ultra-high performance liquid chromatography) instrument that can\n                  be<br/>operated with the ultrahigh-resolution mass spectrometer, and the combined\n                  UHPLCHRMS<br/>system is operated within the same software environment.<br/>• A nanoflow\n                  UHPLC instrument capable of operating from 1 nanoliter per minute to 100 microliter\n                  per minute in flow rate, and at backpressures up to 1500 bar.<br/>• A nanoflow UHPLC\n                  instrument that consist of a binary high-pressure gradient pump, splitloop<br/>autosampler,\n                  an active nanoflow control unit and onboard user interface for immediate<br/>operation.<br/>•\n                  A UHPLC instrument capable of maintaining sample temperature control within 4-40 oC<br/>and\n                  holding at least 216 sample vials at the same time.<br/>• The UHPLC sampler must support\n                  a sample capacity of four sample racks and well plates<br/>(96 and 384, deep and shallow)\n                  without the need for external devices such as plate feeder.<br/>• The user interface\n                  must provide guided workflow exchange and maintenance procedures.<br/>• The mass spectrometer\n                  (MS) must be capable of operating at one million or higher in mass<br/>resolution\n                  at mass-to-charge (m/z) 200 to resolve complex environmental matrices.<br/>• A mass\n                  spectrometer capable of performing higher-energy collisional dissiciation and ultraviolet\n                  photodissociation for multi-stage MSn-fragmentation in liquid chromatography time<br/>scale.<br/>•\n                  A mass spectrometer capable of fragment ion detection in either ion trap or high-resolution<br/>analyzer<br/>•\n                  A mass spectrometer capable of isolating precursor ions with a quadrupole filter with\n                  0.7<br/>FWHM resolution for 50&lt;m/z&lt;1000.<br/>• A mass spectrometer that can perform\n                  automated iterative data-dependent acquisition in<br/>an integrated software solution.<br/>•\n                  A mass spectrometer that can perform data-dependent acquisition and data-independent<br/>acquisition.<br/>•\n                  A mass spectrometer with three mass analyzers build on quadrupole, linear ion trap,\n                  and<br/>Orbitrap technology.<br/>• A mass spectrometer with two independent mass detectors\n                  - one of them based linear ion<br/>trap technology - and both detectors must be capable\n                  of operating in parallel with each<br/>other.<br/>• A mass spectrometer with a removable\n                  ion sweep cone.<br/>• The mass spectrometer must be capable of switching polarities\n                  within 25 mili seconds<br/>• The mass spectrometer must be able to perform up to 10\n                  stages of data-dependent fragmentations (MSn).<br/>• A mass spectrometer with normalized\n                  collision energy capability to automatically compensate<br/>for the mass dependent\n                  energy deposition and provide instrument-to-instrument fragmentation<br/>reproducibility.<br/>•\n                  A mass spectrometer with a data-dependent decision tree logic to automatic determine\n                  optimal fragmentation technique and analyzer during the LC run.<br/>• The high resolution\n                  mass analyzer must at least have an intra-spectrum dynamic range of<br/>5000.<br/>•\n                  An ultraviolet photodissociation technology using a 213 nm laser architecture that\n                  is fully<br/>integrated in the mass spectrometer.</span></section>\n            <section><span class=\"label\">Identifikator for proceduren</span><span class=\"text\">: </span><span class=\"value\">e2d1bb17-3137-4d25-92c3-9b27224484af</span></section>\n            <section><span class=\"label\">Tidligere bekendtgørelse</span><span class=\"text\">: </span><span class=\"value\">182365cc-d3f8-4ff3-845d-bb9241cd807f-01</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10694</span></section>\n            <section><span class=\"label\">Udbudsprocedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Udbud med forhandling uden forudgående offentliggørelse</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433100</span><span class=\"text\"> </span><span class=\"dynamic-label\">Massespektrometer</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratorieudstyr, optisk udstyr og præcisionsudstyr (ikke briller)</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38400000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Instrumenter til kontrol af fysiske karakteristika</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38430000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Apparater til fysisk eller kemisk analyse</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Spektrometre</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Miljøvej, building 113</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n               <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n               <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n               <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            </section>\n            <section>2.1.3&nbsp;<span class=\"label\">Værdi</span><section><span class=\"label\">Anslået værdi eksklusiv moms</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Dansk krone</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Indkaldelse af tilbud er afsluttet</span></section>\n               <section><span class=\"label\">Retsgrundlag</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Direktiv 2014/24/EU</span></section>\n               <section><span class=\"value\">The Danish Public Procurement Law</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">The Danish Public Procurement Law</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Delkontrakt</span><section>5.1&nbsp;<span class=\"label\">Delkontrakt</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU Sustain is working with environmental forensics and metabolomic investigations\n                  to study the fate and occurrence of chemicals and small molecules dispersed into the\n                  environment. <br/><br/>To be able to make these investigations, DTU wants to procure\n                  a low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform,\n                  capable of characterizing small molecules with collisional dissociation and laser-based\n                  ultraviolet-photodissociation (UVPD) for multi-stage molecular fragmentation (MSn)\n                  in liquid chromatography time scale. The mass spectrometer platform must have two\n                  independent mass detectors, and capable of resolving very complex molecular mixtures\n                  to improve unknown chemical characterization with fine isotope detection at one million\n                  in mass resolution (at mass-to-charge 200) or higher. The liquid chromatography system\n                  must be able to make chromatographic separations of complex mixtures at low-flow conditions\n                  (10-100 nano-liters per minute) and seamlessly integrated with nanoelectrospray ionization\n                  and controlled, jointly with themass spectrometer, within the same software environment.<br/><br/>In\n                  addition, the combined system must have;<br/>• Two atmospheric pressure ionisation\n                  interfaces; heated electrospray ionisation (HESI) and<br/>nano-spray ionisation (NSI).<br/>•\n                  A nanoflow UHPLC (ultra-high performance liquid chromatography) instrument that can\n                  be<br/>operated with the ultrahigh-resolution mass spectrometer, and the combined\n                  UHPLCHRMS<br/>system is operated within the same software environment.<br/>• A nanoflow\n                  UHPLC instrument capable of operating from 1 nanoliter per minute to 100 microliter\n                  per minute in flow rate, and at backpressures up to 1500 bar.<br/>• A nanoflow UHPLC\n                  instrument that consist of a binary high-pressure gradient pump, splitloop<br/>autosampler,\n                  an active nanoflow control unit and onboard user interface for immediate<br/>operation.<br/>•\n                  A UHPLC instrument capable of maintaining sample temperature control within 4-40 oC<br/>and\n                  holding at least 216 sample vials at the same time.<br/>• The UHPLC sampler must support\n                  a sample capacity of four sample racks and well plates<br/>(96 and 384, deep and shallow)\n                  without the need for external devices such as plate feeder.<br/>• The user interface\n                  must provide guided workflow exchange and maintenance procedures.<br/>• The mass spectrometer\n                  (MS) must be capable of operating at one million or higher in mass<br/>resolution\n                  at mass-to-charge (m/z) 200 to resolve complex environmental matrices.<br/>• A mass\n                  spectrometer capable of performing higher-energy collisional dissiciation and ultraviolet\n                  photodissociation for multi-stage MSn-fragmentation in liquid chromatography time<br/>scale.<br/>•\n                  A mass spectrometer capable of fragment ion detection in either ion trap or high-resolution<br/>analyzer<br/>•\n                  A mass spectrometer capable of isolating precursor ions with a quadrupole filter with\n                  0.7<br/>FWHM resolution for 50&lt;m/z&lt;1000.<br/>• A mass spectrometer that can perform\n                  automated iterative data-dependent acquisition in<br/>an integrated software solution.<br/>•\n                  A mass spectrometer that can perform data-dependent acquisition and data-independent<br/>acquisition.<br/>•\n                  A mass spectrometer with three mass analyzers build on quadrupole, linear ion trap,\n                  and<br/>Orbitrap technology.<br/>• A mass spectrometer with two independent mass detectors\n                  - one of them based linear ion<br/>trap technology - and both detectors must be capable\n                  of operating in parallel with each<br/>other.<br/>• A mass spectrometer with a removable\n                  ion sweep cone.<br/>• The mass spectrometer must be capable of switching polarities\n                  within 25 mili seconds<br/>• The mass spectrometer must be able to perform up to 10\n                  stages of data-dependent fragmentations (MSn).<br/>• A mass spectrometer with normalized\n                  collision energy capability to automatically compensate<br/>for the mass dependent\n                  energy deposition and provide instrument-to-instrument fragmentation<br/>reproducibility.<br/>•\n                  A mass spectrometer with a data-dependent decision tree logic to automatic determine\n                  optimal fragmentation technique and analyzer during the LC run.<br/>• The high resolution\n                  mass analyzer must at least have an intra-spectrum dynamic range of<br/>5000.<br/>•\n                  An ultraviolet photodissociation technology using a 213 nm laser architecture that\n                  is fully<br/>integrated in the mass spectrometer.</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10694</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433100</span><span class=\"text\"> </span><span class=\"dynamic-label\">Massespektrometer</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratorieudstyr, optisk udstyr og præcisionsudstyr (ikke briller)</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38400000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Instrumenter til kontrol af fysiske karakteristika</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38430000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Apparater til fysisk eller kemisk analyse</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Spektrometre</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Miljøvej, building 113</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n               <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n               <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n               <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n               <section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.3&nbsp;<span class=\"label\">Anslået varighed</span><section><span class=\"label\">Varighed</span><span class=\"text\">: </span><span class=\"value\">1</span><span class=\"text\"> </span><span class=\"label\">År</span></section>\n            </section>\n            <section>5.1.5&nbsp;<span class=\"label\">Værdi</span><section><span class=\"label\">Anslået værdi eksklusiv moms</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Dansk krone</span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"dynamic-label\">Indkøbsprojekt, der ikke finansieres med EU-midler</span></section>\n               <section><span class=\"label\">Udbuddet er omfattet af aftalen om offentlige udbud (GPA)</span><span class=\"text\">: </span><span class=\"label\">ja</span></section>\n            </section>\n            <section>5.1.10&nbsp;<span class=\"label\">Tildelingskriterier</span><section><span class=\"label\">Kriterium</span><span class=\"text\">:</span><section><span class=\"label\">Type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kvalitet</span></section>\n                  <section><span class=\"label\">Navn</span><span class=\"text\">: </span><span class=\"value\">Kvalitet</span></section>\n                  <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">Technical.</span></section>\n                  <section><span class=\"label\">Kategori for tildelingskriteriet vægt</span><span class=\"text\">: </span><span class=\"dynamic-label\">Vægtning (procentdel, præcis)</span><section><span class=\"label\">Tildelingskriterium talværdi</span><span class=\"text\">: </span><span class=\"value\">100</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>5.1.15&nbsp;<span class=\"label\">Teknikker</span><section><span class=\"label\">Rammeaftale</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">Ingen rammeaftale</span></section>\n               </section>\n               <section><span class=\"label\">Oplysninger om det dynamiske indkøbssystem</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">Intet dynamisk indkøbssystem</span></section>\n               </section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Yderligere oplysninger, mægling og gennemgang</span><section><span class=\"label\">Organisation med ansvar for klager</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Oplysninger om klagefrister</span><span class=\"text\">: </span><span class=\"value\">Complaint regarding direct award of contract:<br/>Complaint that the Contracting Authority,\n                     contrary to the Public Procurement Act, has concluded a contract without prior publication\n                     of a contract notice in the European Union Official Journal must be submitted no later\n                     than 30 calendar days from the date after a contract award notice has been published\n                     by the Contracting Authority in the European Union Official Journal and that contract\n                     award notice includes the grounds for the decision to award the contract directly,\n                     cf. lov om Klagenævnet for Udbud (Complaints Board for Tenders) § 7, section 3.</span></section>\n               <section><span class=\"label\">Organisation, der leverer supplerende oplysninger om udbudsproceduren</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der sikrer adgang til udbudsdokumenterne offline</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, hvis budget anvendes til at betale for kontrakten</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n               <section><span class=\"label\">Organisation, der udfører betalingen</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n               <section><span class=\"label\">Organisation, der underskriver kontrakten</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Resultater</span><section><span class=\"label\">Værdien af alle kontrakter tildelt i denne bekendtgørelse</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Dansk krone</span></section>\n         <section><span class=\"label\">Direkte tildeling</span><span class=\"text\">:</span><section><span class=\"label\">Begrundelse for direkte tildeling</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kontrakten kan kun tildeles af en bestemt økonomisk aktør på grund af manglende konkurrence af tekniske årsager</span></section>\n            <section><span class=\"label\">Anden begrundelse</span><span class=\"text\">: </span><span class=\"value\">As mentioned above DTU Sustain is working with environmental forensics and metabolomic\n                  investigations to study the fate and occurrence of chemicals and small molecules dispersed\n                  into the environment. The work involves creating untargeted metabolomic and non-target\n                  chemical analysis data recordings of trace level chemicals in complex environmental\n                  samples using liquid chromatography hyphenated with ultrahigh-resolution mass spectrometry.\n                  To be able to make these investigations, DTU wants to procure the instrument described\n                  above. The system will be essential for the research and teaching at DTU Sustain in\n                  describing and understanding environmental fate and occurrence processes of emerging\n                  pollutants.<br/><br/>After extensive market research of commercially available systems\n                  and suppliers, DTU Sustain has concluded that the NanoUHPLC-HRMS/MS IQ-X system operating\n                  at 1 million in mass resolution with UVPD from Thermo Scientific is the only instrument\n                  meeting the high technical requirements needed for DTU Sustain to perform the variety\n                  of state-of-the-art experimental environmental research.<br/><br/>Purchasing the NanoUHPLC-HRMS/MS\n                  IQ-X platform operating at 1 million in mass resolution with UVPD system from Thermo\n                  Scientific will fulfil the requirements from DTU Sustain and its broader user base\n                  and research areas as described above. No other supplier can deliver a similar system\n                  capable of solving the listed challenges.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Resultat delkontrakt-ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"dynamic-label\">Der er udvalgt mindst én vinder.</span></section>\n            <section>6.1.2&nbsp;<span class=\"label\">Oplysninger om vinderne</span><section><span class=\"label\">Vinder</span><span class=\"text\">:</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n                  <section><span class=\"label\">Tilbud</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tilbud – Identifikator</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n                  <section><span class=\"label\">ID for delkontrakt eller gruppe af delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Værdien af tilbuddet</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Dansk krone</span></section>\n                  <section><span class=\"label\">Tilbuddet blev rangordnet</span><span class=\"text\">: </span><span class=\"label\">nej</span></section>\n                  <section><span class=\"label\">Underentreprise</span><span class=\"text\">: </span><span class=\"dynamic-label\">Endnu ikke kendte</span></section>\n                  <section><span class=\"label\">Kontraktoplysninger</span><span class=\"text\">:</span><section><span class=\"label\">Identifikator for kontrakten</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n                     <section><span class=\"label\">Datoen for udvælgelsen af det vindende tilbud</span><span class=\"text\">: </span><span class=\"value\">05-03-2026</span></section>\n                     <section><span class=\"label\">Dato for indgåelse af kontrakten</span><span class=\"text\">: </span><span class=\"value\">20-03-2026</span></section>\n                     <section><span class=\"label\">Organisation, der underskriver kontrakten</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>6.1.4&nbsp;<span class=\"label\">Statistiske oplysninger</span><section><span class=\"label\">Resumé af de klager som køberen har modtaget</span><span class=\"text\">:</span><section><span class=\"label\">Antal klagere</span><span class=\"text\">: </span><span class=\"value\">0</span></section>\n               </section>\n               <section><span class=\"label\">Modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">:</span><section><span class=\"label\">Type modtagne indgivelser</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tilbud</span><section><span class=\"label\">Antal modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n               </section>\n               <section><span class=\"label\">Udvalg af tilbud</span><span class=\"text\">:</span><section><span class=\"label\">Værdien af det antagelige tilbud med den laveste værdi</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Dansk krone</span></section>\n                  <section><span class=\"label\">Værdien af det antagelige tilbud med den højeste værdi</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Dansk krone</span></section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisationer</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">Katrine Freiesleben Petersen</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">kafre@dtu.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 45252525</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Køberprofil</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Køber</span></section>\n               <section><span class=\"label\">Organisation, der leverer supplerende oplysninger om udbudsproceduren</span></section>\n               <section><span class=\"label\">Organisation, der sikrer adgang til udbudsdokumenterne offline</span></section>\n               <section><span class=\"label\">Organisation, der underskriver kontrakten</span></section>\n               <section><span class=\"label\">Organisation, hvis budget anvendes til at betale for kontrakten</span></section>\n               <section><span class=\"label\">Organisation, der udfører betalingen</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for klager</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n            <section><span class=\"label\">Den økonomiske operatørs størrelse</span><span class=\"text\">: </span><span class=\"label\">Mikrovirksomhed, lille eller mellemstor virksomhed</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">28314388</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Gydevang 33</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Allerød</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">3450</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Nordsjælland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK013</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Tilbudsgiver</span></section>\n               <section><span class=\"label\">Vinder af disse delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norge</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Oplysninger om bekendtgørelsen</span><section><span class=\"label\">Bekendtgørelsens ID</span><span class=\"text\">: </span><span class=\"value\">ecf233c2-3a70-4d48-9767-5d1a18a83e53</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Formulartype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Resultater</span></section>\n         <section><span class=\"label\">Bekendtgørelsestype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Bekendtgørelse om indgåede kontrakter eller koncessionstildeling – standardordningen</span></section>\n         <section><span class=\"label\">Afsendelsesdato for bekendtgørelsen</span><span class=\"text\">: </span><span class=\"value\">25-03-2026</span><span class=\"text\"> </span><span class=\"value\">08:33 +00:00</span></section>\n         <section><span class=\"label\">Dato for afsendelse af bekendtgørelsen (eSender)</span><span class=\"text\">: </span><span class=\"value\">25-03-2026</span><span class=\"text\"> </span><span class=\"value\">08:33 +00:00</span></section>\n         <section><span class=\"label\">Bekendtgørelsens officielle sprog</span><span class=\"text\">: </span><span class=\"dynamic-label\">engelsk</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Bekendtgørelsesnummer</span><span class=\"text\">: </span><span class=\"value\">00209494-2026</span></section>\n         <section><span class=\"label\">EUT-S-nummer</span><span class=\"text\">: </span><span class=\"value\">60/2026</span></section>\n         <section><span class=\"label\">Offentliggørelsesdato</span><span class=\"text\">: </span><span class=\"value\">26-03-2026</span></section>\n      </section>\n   </body>\n</html>","htmlEN":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Buyer</span><section>1.1&nbsp;<span class=\"label\">Buyer</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Legal type of the buyer</span><span class=\"text\">: </span><span class=\"dynamic-label\">Body governed by public law</span></section>\n            <section><span class=\"label\">Activity of the contracting authority</span><span class=\"text\">: </span><span class=\"dynamic-label\">Education</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU Sustain is working with environmental forensics and metabolomic investigations\n                  to study the fate and occurrence of chemicals and small molecules dispersed into the\n                  environment. <br/><br/>To be able to make these investigations, DTU wants to procure\n                  a low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform,\n                  capable of characterizing small molecules with collisional dissociation and laser-based\n                  ultraviolet-photodissociation (UVPD) for multi-stage molecular fragmentation (MSn)\n                  in liquid chromatography time scale. The mass spectrometer platform must have two\n                  independent mass detectors, and capable of resolving very complex molecular mixtures\n                  to improve unknown chemical characterization with fine isotope detection at one million\n                  in mass resolution (at mass-to-charge 200) or higher. The liquid chromatography system\n                  must be able to make chromatographic separations of complex mixtures at low-flow conditions\n                  (10-100 nano-liters per minute) and seamlessly integrated with nanoelectrospray ionization\n                  and controlled, jointly with themass spectrometer, within the same software environment.<br/><br/>In\n                  addition, the combined system must have;<br/>• Two atmospheric pressure ionisation\n                  interfaces; heated electrospray ionisation (HESI) and<br/>nano-spray ionisation (NSI).<br/>•\n                  A nanoflow UHPLC (ultra-high performance liquid chromatography) instrument that can\n                  be<br/>operated with the ultrahigh-resolution mass spectrometer, and the combined\n                  UHPLCHRMS<br/>system is operated within the same software environment.<br/>• A nanoflow\n                  UHPLC instrument capable of operating from 1 nanoliter per minute to 100 microliter\n                  per minute in flow rate, and at backpressures up to 1500 bar.<br/>• A nanoflow UHPLC\n                  instrument that consist of a binary high-pressure gradient pump, splitloop<br/>autosampler,\n                  an active nanoflow control unit and onboard user interface for immediate<br/>operation.<br/>•\n                  A UHPLC instrument capable of maintaining sample temperature control within 4-40 oC<br/>and\n                  holding at least 216 sample vials at the same time.<br/>• The UHPLC sampler must support\n                  a sample capacity of four sample racks and well plates<br/>(96 and 384, deep and shallow)\n                  without the need for external devices such as plate feeder.<br/>• The user interface\n                  must provide guided workflow exchange and maintenance procedures.<br/>• The mass spectrometer\n                  (MS) must be capable of operating at one million or higher in mass<br/>resolution\n                  at mass-to-charge (m/z) 200 to resolve complex environmental matrices.<br/>• A mass\n                  spectrometer capable of performing higher-energy collisional dissiciation and ultraviolet\n                  photodissociation for multi-stage MSn-fragmentation in liquid chromatography time<br/>scale.<br/>•\n                  A mass spectrometer capable of fragment ion detection in either ion trap or high-resolution<br/>analyzer<br/>•\n                  A mass spectrometer capable of isolating precursor ions with a quadrupole filter with\n                  0.7<br/>FWHM resolution for 50&lt;m/z&lt;1000.<br/>• A mass spectrometer that can perform\n                  automated iterative data-dependent acquisition in<br/>an integrated software solution.<br/>•\n                  A mass spectrometer that can perform data-dependent acquisition and data-independent<br/>acquisition.<br/>•\n                  A mass spectrometer with three mass analyzers build on quadrupole, linear ion trap,\n                  and<br/>Orbitrap technology.<br/>• A mass spectrometer with two independent mass detectors\n                  - one of them based linear ion<br/>trap technology - and both detectors must be capable\n                  of operating in parallel with each<br/>other.<br/>• A mass spectrometer with a removable\n                  ion sweep cone.<br/>• The mass spectrometer must be capable of switching polarities\n                  within 25 mili seconds<br/>• The mass spectrometer must be able to perform up to 10\n                  stages of data-dependent fragmentations (MSn).<br/>• A mass spectrometer with normalized\n                  collision energy capability to automatically compensate<br/>for the mass dependent\n                  energy deposition and provide instrument-to-instrument fragmentation<br/>reproducibility.<br/>•\n                  A mass spectrometer with a data-dependent decision tree logic to automatic determine\n                  optimal fragmentation technique and analyzer during the LC run.<br/>• The high resolution\n                  mass analyzer must at least have an intra-spectrum dynamic range of<br/>5000.<br/>•\n                  An ultraviolet photodissociation technology using a 213 nm laser architecture that\n                  is fully<br/>integrated in the mass spectrometer.</span></section>\n            <section><span class=\"label\">Procedure identifier</span><span class=\"text\">: </span><span class=\"value\">e2d1bb17-3137-4d25-92c3-9b27224484af</span></section>\n            <section><span class=\"label\">Previous notice</span><span class=\"text\">: </span><span class=\"value\">182365cc-d3f8-4ff3-845d-bb9241cd807f-01</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10694</span></section>\n            <section><span class=\"label\">Type of procedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Negotiated without prior call for competition</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433100</span><span class=\"text\"> </span><span class=\"dynamic-label\">Mass spectrometer</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratory, optical and precision equipments (excl. glasses)</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38400000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Instruments for checking physical characteristics</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38430000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Detection and analysis apparatus</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Spectrometers</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Miljøvej, building 113</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n               <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n               <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            </section>\n            <section>2.1.3&nbsp;<span class=\"label\">Value</span><section><span class=\"label\">Estimated value excluding VAT</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Danish krone</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">Call for competition is terminated</span></section>\n               <section><span class=\"label\">Legal basis</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Directive 2014/24/EU</span></section>\n               <section><span class=\"value\">The Danish Public Procurement Law</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">The Danish Public Procurement Law</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Lot</span><section>5.1&nbsp;<span class=\"label\">Lot</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU Sustain is working with environmental forensics and metabolomic investigations\n                  to study the fate and occurrence of chemicals and small molecules dispersed into the\n                  environment. <br/><br/>To be able to make these investigations, DTU wants to procure\n                  a low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform,\n                  capable of characterizing small molecules with collisional dissociation and laser-based\n                  ultraviolet-photodissociation (UVPD) for multi-stage molecular fragmentation (MSn)\n                  in liquid chromatography time scale. The mass spectrometer platform must have two\n                  independent mass detectors, and capable of resolving very complex molecular mixtures\n                  to improve unknown chemical characterization with fine isotope detection at one million\n                  in mass resolution (at mass-to-charge 200) or higher. The liquid chromatography system\n                  must be able to make chromatographic separations of complex mixtures at low-flow conditions\n                  (10-100 nano-liters per minute) and seamlessly integrated with nanoelectrospray ionization\n                  and controlled, jointly with themass spectrometer, within the same software environment.<br/><br/>In\n                  addition, the combined system must have;<br/>• Two atmospheric pressure ionisation\n                  interfaces; heated electrospray ionisation (HESI) and<br/>nano-spray ionisation (NSI).<br/>•\n                  A nanoflow UHPLC (ultra-high performance liquid chromatography) instrument that can\n                  be<br/>operated with the ultrahigh-resolution mass spectrometer, and the combined\n                  UHPLCHRMS<br/>system is operated within the same software environment.<br/>• A nanoflow\n                  UHPLC instrument capable of operating from 1 nanoliter per minute to 100 microliter\n                  per minute in flow rate, and at backpressures up to 1500 bar.<br/>• A nanoflow UHPLC\n                  instrument that consist of a binary high-pressure gradient pump, splitloop<br/>autosampler,\n                  an active nanoflow control unit and onboard user interface for immediate<br/>operation.<br/>•\n                  A UHPLC instrument capable of maintaining sample temperature control within 4-40 oC<br/>and\n                  holding at least 216 sample vials at the same time.<br/>• The UHPLC sampler must support\n                  a sample capacity of four sample racks and well plates<br/>(96 and 384, deep and shallow)\n                  without the need for external devices such as plate feeder.<br/>• The user interface\n                  must provide guided workflow exchange and maintenance procedures.<br/>• The mass spectrometer\n                  (MS) must be capable of operating at one million or higher in mass<br/>resolution\n                  at mass-to-charge (m/z) 200 to resolve complex environmental matrices.<br/>• A mass\n                  spectrometer capable of performing higher-energy collisional dissiciation and ultraviolet\n                  photodissociation for multi-stage MSn-fragmentation in liquid chromatography time<br/>scale.<br/>•\n                  A mass spectrometer capable of fragment ion detection in either ion trap or high-resolution<br/>analyzer<br/>•\n                  A mass spectrometer capable of isolating precursor ions with a quadrupole filter with\n                  0.7<br/>FWHM resolution for 50&lt;m/z&lt;1000.<br/>• A mass spectrometer that can perform\n                  automated iterative data-dependent acquisition in<br/>an integrated software solution.<br/>•\n                  A mass spectrometer that can perform data-dependent acquisition and data-independent<br/>acquisition.<br/>•\n                  A mass spectrometer with three mass analyzers build on quadrupole, linear ion trap,\n                  and<br/>Orbitrap technology.<br/>• A mass spectrometer with two independent mass detectors\n                  - one of them based linear ion<br/>trap technology - and both detectors must be capable\n                  of operating in parallel with each<br/>other.<br/>• A mass spectrometer with a removable\n                  ion sweep cone.<br/>• The mass spectrometer must be capable of switching polarities\n                  within 25 mili seconds<br/>• The mass spectrometer must be able to perform up to 10\n                  stages of data-dependent fragmentations (MSn).<br/>• A mass spectrometer with normalized\n                  collision energy capability to automatically compensate<br/>for the mass dependent\n                  energy deposition and provide instrument-to-instrument fragmentation<br/>reproducibility.<br/>•\n                  A mass spectrometer with a data-dependent decision tree logic to automatic determine\n                  optimal fragmentation technique and analyzer during the LC run.<br/>• The high resolution\n                  mass analyzer must at least have an intra-spectrum dynamic range of<br/>5000.<br/>•\n                  An ultraviolet photodissociation technology using a 213 nm laser architecture that\n                  is fully<br/>integrated in the mass spectrometer.</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10694</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433100</span><span class=\"text\"> </span><span class=\"dynamic-label\">Mass spectrometer</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratory, optical and precision equipments (excl. glasses)</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38400000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Instruments for checking physical characteristics</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38430000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Detection and analysis apparatus</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38433000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Spectrometers</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Miljøvej, building 113</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n               <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n               <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n               <section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.3&nbsp;<span class=\"label\">Estimated duration</span><section><span class=\"label\">Duration</span><span class=\"text\">: </span><span class=\"value\">1</span><span class=\"text\"> </span><span class=\"label\">Year</span></section>\n            </section>\n            <section>5.1.5&nbsp;<span class=\"label\">Value</span><section><span class=\"label\">Estimated value excluding VAT</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Danish krone</span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">General information</span><section><span class=\"dynamic-label\">Procurement Project not financed with EU Funds.</span></section>\n               <section><span class=\"label\">The procurement is covered by the Government Procurement Agreement (GPA)</span><span class=\"text\">: </span><span class=\"label\">yes</span></section>\n            </section>\n            <section>5.1.10&nbsp;<span class=\"label\">Award criteria</span><section><span class=\"label\">Criterion</span><span class=\"text\">:</span><section><span class=\"label\">Type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Quality</span></section>\n                  <section><span class=\"label\">Name</span><span class=\"text\">: </span><span class=\"value\">Kvalitet</span></section>\n                  <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">Technical.</span></section>\n                  <section><span class=\"label\">Category of award weight criterion</span><span class=\"text\">: </span><span class=\"dynamic-label\">Weight (percentage, exact)</span><section><span class=\"label\">Award criterion number</span><span class=\"text\">: </span><span class=\"value\">100</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>5.1.15&nbsp;<span class=\"label\">Techniques</span><section><span class=\"label\">Framework agreement</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">No framework agreement</span></section>\n               </section>\n               <section><span class=\"label\">Information about the dynamic purchasing system</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">No dynamic purchase system</span></section>\n               </section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Further information, mediation and review</span><section><span class=\"label\">Review organisation</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Information about review deadlines</span><span class=\"text\">: </span><span class=\"value\">Complaint regarding direct award of contract:<br/>Complaint that the Contracting Authority,\n                     contrary to the Public Procurement Act, has concluded a contract without prior publication\n                     of a contract notice in the European Union Official Journal must be submitted no later\n                     than 30 calendar days from the date after a contract award notice has been published\n                     by the Contracting Authority in the European Union Official Journal and that contract\n                     award notice includes the grounds for the decision to award the contract directly,\n                     cf. lov om Klagenævnet for Udbud (Complaints Board for Tenders) § 7, section 3.</span></section>\n               <section><span class=\"label\">Organisation providing additional information about the procurement procedure</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing offline access to the procurement documents</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation whose budget is used to pay for the contract</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n               <section><span class=\"label\">Organisation executing the payment</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n               <section><span class=\"label\">Organisation signing the contract</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Results</span><section><span class=\"label\">Value of all contracts awarded in this notice</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Danish krone</span></section>\n         <section><span class=\"label\">Direct award</span><span class=\"text\">:</span><section><span class=\"label\">Justification for direct award</span><span class=\"text\">: </span><span class=\"dynamic-label\">The contract can be provided only by a particular economic operator because of an absence of competition for technical reasons</span></section>\n            <section><span class=\"label\">Other justification</span><span class=\"text\">: </span><span class=\"value\">As mentioned above DTU Sustain is working with environmental forensics and metabolomic\n                  investigations to study the fate and occurrence of chemicals and small molecules dispersed\n                  into the environment. The work involves creating untargeted metabolomic and non-target\n                  chemical analysis data recordings of trace level chemicals in complex environmental\n                  samples using liquid chromatography hyphenated with ultrahigh-resolution mass spectrometry.\n                  To be able to make these investigations, DTU wants to procure the instrument described\n                  above. The system will be essential for the research and teaching at DTU Sustain in\n                  describing and understanding environmental fate and occurrence processes of emerging\n                  pollutants.<br/><br/>After extensive market research of commercially available systems\n                  and suppliers, DTU Sustain has concluded that the NanoUHPLC-HRMS/MS IQ-X system operating\n                  at 1 million in mass resolution with UVPD from Thermo Scientific is the only instrument\n                  meeting the high technical requirements needed for DTU Sustain to perform the variety\n                  of state-of-the-art experimental environmental research.<br/><br/>Purchasing the NanoUHPLC-HRMS/MS\n                  IQ-X platform operating at 1 million in mass resolution with UVPD system from Thermo\n                  Scientific will fulfil the requirements from DTU Sustain and its broader user base\n                  and research areas as described above. No other supplier can deliver a similar system\n                  capable of solving the listed challenges.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Result lot identifier</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"dynamic-label\">At least one winner was chosen.</span></section>\n            <section>6.1.2&nbsp;<span class=\"label\">Information about winners</span><section><span class=\"label\">Winner</span><span class=\"text\">:</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n                  <section><span class=\"label\">Tender</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tender identifier</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n                  <section><span class=\"label\">Identifier of lot or group of lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Value of the tender</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Danish krone</span></section>\n                  <section><span class=\"label\">The tender was ranked</span><span class=\"text\">: </span><span class=\"label\">no</span></section>\n                  <section><span class=\"label\">Subcontracting</span><span class=\"text\">: </span><span class=\"dynamic-label\">Not yet known</span></section>\n                  <section><span class=\"label\">Contract information</span><span class=\"text\">:</span><section><span class=\"label\">Identifier of the contract</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n                     <section><span class=\"label\">Date on which the winner was chosen</span><span class=\"text\">: </span><span class=\"value\">05-03-2026</span></section>\n                     <section><span class=\"label\">Date of the conclusion of the contract</span><span class=\"text\">: </span><span class=\"value\">20-03-2026</span></section>\n                     <section><span class=\"label\">Organisation signing the contract</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>6.1.4&nbsp;<span class=\"label\">Statistical information</span><section><span class=\"label\">Summary of the review requests the buyer received</span><span class=\"text\">:</span><section><span class=\"label\">Number of complainants</span><span class=\"text\">: </span><span class=\"value\">0</span></section>\n               </section>\n               <section><span class=\"label\">Received tenders or requests to participate</span><span class=\"text\">:</span><section><span class=\"label\">Type of received submissions</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tenders</span><section><span class=\"label\">Number of tenders or requests to participate received</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n               </section>\n               <section><span class=\"label\">Range of tenders</span><span class=\"text\">:</span><section><span class=\"label\">Value of the lowest admissible tender</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Danish krone</span></section>\n                  <section><span class=\"label\">Value of the highest admissible tender</span><span class=\"text\">: </span><span class=\"value\">4.500.000</span><span class=\"text\"> </span><span class=\"label\">Danish krone</span></section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisations</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">Katrine Freiesleben Petersen</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">kafre@dtu.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 45252525</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Buyer profile</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Buyer</span></section>\n               <section><span class=\"label\">Organisation providing additional information about the procurement procedure</span></section>\n               <section><span class=\"label\">Organisation providing offline access to the procurement documents</span></section>\n               <section><span class=\"label\">Organisation signing the contract</span></section>\n               <section><span class=\"label\">Organisation whose budget is used to pay for the contract</span></section>\n               <section><span class=\"label\">Organisation executing the payment</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Review organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Organisation providing more information on the review procedures</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Thermo Electron A/S</span></section>\n            <section><span class=\"label\">Size of the economic operator</span><span class=\"text\">: </span><span class=\"label\">Micro, small, or medium</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">28314388</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Gydevang 33</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Allerød</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">3450</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Nordsjælland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK013</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Tenderer</span></section>\n               <section><span class=\"label\">Winner of these lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norway</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Notice information</span><section><span class=\"label\">Notice identifier/version</span><span class=\"text\">: </span><span class=\"value\">ecf233c2-3a70-4d48-9767-5d1a18a83e53</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Form type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Result</span></section>\n         <section><span class=\"label\">Notice type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Contract or concession award notice – standard regime</span></section>\n         <section><span class=\"label\">Notice dispatch date</span><span class=\"text\">: </span><span class=\"value\">25-03-2026</span><span class=\"text\"> </span><span class=\"value\">08:33 +00:00</span></section>\n         <section><span class=\"label\">Notice dispatch date (eSender)</span><span class=\"text\">: </span><span class=\"value\">25-03-2026</span><span class=\"text\"> </span><span class=\"value\">08:33 +00:00</span></section>\n         <section><span class=\"label\">Languages in which this notice is officially available</span><span class=\"text\">: </span><span class=\"dynamic-label\">English</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Notice publication number</span><span class=\"text\">: </span><span class=\"value\">00209494-2026</span></section>\n         <section><span class=\"label\">OJ S issue number</span><span class=\"text\">: </span><span class=\"value\">60/2026</span></section>\n         <section><span class=\"label\">Publication date</span><span class=\"text\">: </span><span class=\"value\">26-03-2026</span></section>\n      </section>\n   </body>\n</html>","opsummeringDA":{"card":{"titel":"Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2026-03-26+01:00","cpvKode":"38433100","cpvTitel":"Massespektrometer","formulartype":"Resultater","formulartypeKode":"result","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"anslaaetVaerdi":"4500000","anslaaetVaerdiValuta":"DKK","beskrivelse":"DTU Sustain is working with environmental forensics and metabolomic investigations to study the fate and occurrence of chemicals and small molecules dispersed into the environment.  \n\nTo be able to make these investigations, DTU wants to procure a low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform, capable of characterizing small molecules with collisional dissociation and laser-based ultraviolet-photodissociation (UVPD) for multi-stage molecular fragmentation (MSn) in liquid chromatography time scale. The mass spectrometer platform must have two independent mass detectors, and capable of resolving very complex molecular mixtures to improve unknown chemical characterization with fine isotope detection at one million in mass resolution (at mass-to-charge 200) or higher. The liquid chromatography system must be able to make chromatographic separations of complex mixtures at low-flow conditions (10-100 nano-liters per minute) and seamlessly integrated with nanoelectrospray ionization and controlled, jointly with themass spectrometer, within the same software environment.\n\nIn addition, the combined system must have;\n• Two atmospheric pressure ionisation interfaces; heated electrospray ionisation (HESI) and\nnano-spray ionisation (NSI).\n• A nanoflow UHPLC (ultra-high performance liquid chromatography) instrument that can be\noperated with the ultrahigh-resolution mass spectrometer, and the combined UHPLCHRMS\nsystem is operated within the same software environment.\n• A nanoflow UHPLC instrument capable of operating from 1 nanoliter per minute to 100 microliter per minute in flow rate, and at backpressures up to 1500 bar.\n• A nanoflow UHPLC instrument that consist of a binary high-pressure gradient pump, splitloop\nautosampler, an active nanoflow control unit and onboard user interface for immediate\noperation.\n• A UHPLC instrument capable of maintaining sample temperature control within 4-40 oC\nand holding at least 216 sample vials at the same time.\n• The UHPLC sampler must support a sample capacity of four sample racks and well plates\n(96 and 384, deep and shallow) without the need for external devices such as plate feeder.\n• The user interface must provide guided workflow exchange and maintenance procedures.\n• The mass spectrometer (MS) must be capable of operating at one million or higher in mass\nresolution at mass-to-charge (m/z) 200 to resolve complex environmental matrices.\n• A mass spectrometer capable of performing higher-energy collisional dissiciation and ultraviolet photodissociation for multi-stage MSn-fragmentation in liquid chromatography time\nscale.\n• A mass spectrometer capable of fragment ion detection in either ion trap or high-resolution\nanalyzer\n• A mass spectrometer capable of isolating precursor ions with a quadrupole filter with 0.7\nFWHM resolution for 50<m/z<1000.\n• A mass spectrometer that can perform automated iterative data-dependent acquisition in\nan integrated software solution.\n• A mass spectrometer that can perform data-dependent acquisition and data-independent\nacquisition.\n• A mass spectrometer with three mass analyzers build on quadrupole, linear ion trap, and\nOrbitrap technology.\n• A mass spectrometer with two independent mass detectors - one of them based linear ion\ntrap technology - and both detectors must be capable of operating in parallel with each\nother.\n• A mass spectrometer with a removable ion sweep cone.\n• The mass spectrometer must be capable of switching polarities within 25 mili seconds\n• The mass spectrometer must be able to perform up to 10 stages of data-dependent fragmentations (MSn).\n• A mass spectrometer with normalized collision energy capability to automatically compensate\nfor the mass dependent energy deposition and provide instrument-to-instrument fragmentation\nreproducibility.\n• A mass spectrometer with a data-dependent decision tree logic to automatic determine optimal fragmentation technique and analyzer during the LC run.\n• The high resolution mass analyzer must at least have an intra-spectrum dynamic range of\n5000.\n• An ultraviolet photodissociation technology using a 213 nm laser architecture that is fully\nintegrated in the mass spectrometer.","bkSubTypeKode":"29","bkSubType":"Bekendtgørelse om indgåede kontrakter – det generelle direktiv, standardordningen","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":["DK012"],"udforelsesstedSubLand":["Københavns omegn"],"udforelsesstedLand":["Danmark"],"udforelsesstedBy":["Kgs. Lyngby"],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]},"opsummeringEN":{"card":{"titel":"Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2026-03-26+01:00","cpvKode":"38433100","cpvTitel":"Mass spectrometer","formulartype":"Result","formulartypeKode":"result","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"anslaaetVaerdi":"4500000","anslaaetVaerdiValuta":"DKK","beskrivelse":"DTU Sustain is working with environmental forensics and metabolomic investigations to study the fate and occurrence of chemicals and small molecules dispersed into the environment.  \n\nTo be able to make these investigations, DTU wants to procure a low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform, capable of characterizing small molecules with collisional dissociation and laser-based ultraviolet-photodissociation (UVPD) for multi-stage molecular fragmentation (MSn) in liquid chromatography time scale. The mass spectrometer platform must have two independent mass detectors, and capable of resolving very complex molecular mixtures to improve unknown chemical characterization with fine isotope detection at one million in mass resolution (at mass-to-charge 200) or higher. The liquid chromatography system must be able to make chromatographic separations of complex mixtures at low-flow conditions (10-100 nano-liters per minute) and seamlessly integrated with nanoelectrospray ionization and controlled, jointly with themass spectrometer, within the same software environment.\n\nIn addition, the combined system must have;\n• Two atmospheric pressure ionisation interfaces; heated electrospray ionisation (HESI) and\nnano-spray ionisation (NSI).\n• A nanoflow UHPLC (ultra-high performance liquid chromatography) instrument that can be\noperated with the ultrahigh-resolution mass spectrometer, and the combined UHPLCHRMS\nsystem is operated within the same software environment.\n• A nanoflow UHPLC instrument capable of operating from 1 nanoliter per minute to 100 microliter per minute in flow rate, and at backpressures up to 1500 bar.\n• A nanoflow UHPLC instrument that consist of a binary high-pressure gradient pump, splitloop\nautosampler, an active nanoflow control unit and onboard user interface for immediate\noperation.\n• A UHPLC instrument capable of maintaining sample temperature control within 4-40 oC\nand holding at least 216 sample vials at the same time.\n• The UHPLC sampler must support a sample capacity of four sample racks and well plates\n(96 and 384, deep and shallow) without the need for external devices such as plate feeder.\n• The user interface must provide guided workflow exchange and maintenance procedures.\n• The mass spectrometer (MS) must be capable of operating at one million or higher in mass\nresolution at mass-to-charge (m/z) 200 to resolve complex environmental matrices.\n• A mass spectrometer capable of performing higher-energy collisional dissiciation and ultraviolet photodissociation for multi-stage MSn-fragmentation in liquid chromatography time\nscale.\n• A mass spectrometer capable of fragment ion detection in either ion trap or high-resolution\nanalyzer\n• A mass spectrometer capable of isolating precursor ions with a quadrupole filter with 0.7\nFWHM resolution for 50<m/z<1000.\n• A mass spectrometer that can perform automated iterative data-dependent acquisition in\nan integrated software solution.\n• A mass spectrometer that can perform data-dependent acquisition and data-independent\nacquisition.\n• A mass spectrometer with three mass analyzers build on quadrupole, linear ion trap, and\nOrbitrap technology.\n• A mass spectrometer with two independent mass detectors - one of them based linear ion\ntrap technology - and both detectors must be capable of operating in parallel with each\nother.\n• A mass spectrometer with a removable ion sweep cone.\n• The mass spectrometer must be capable of switching polarities within 25 mili seconds\n• The mass spectrometer must be able to perform up to 10 stages of data-dependent fragmentations (MSn).\n• A mass spectrometer with normalized collision energy capability to automatically compensate\nfor the mass dependent energy deposition and provide instrument-to-instrument fragmentation\nreproducibility.\n• A mass spectrometer with a data-dependent decision tree logic to automatic determine optimal fragmentation technique and analyzer during the LC run.\n• The high resolution mass analyzer must at least have an intra-spectrum dynamic range of\n5000.\n• An ultraviolet photodissociation technology using a 213 nm laser architecture that is fully\nintegrated in the mass spectrometer.","bkSubTypeKode":"29","bkSubType":"Contract award notice – general directive, standard regime","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":["DK012"],"udforelsesstedSubLand":["Københavns omegn"],"udforelsesstedLand":["Denmark"],"udforelsesstedBy":["Kgs. Lyngby"],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]}}