{"bekendtgoerelseNoegle":{"noticeId":{"value":"d4222e47-1291-43bc-aec8-9ae47298833d"},"noticeVersion":{"value":"01"},"noticePublicationNumber":{"value":"00604726-2025"}},"htmlDA":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Køber</span><section>1.1&nbsp;<span class=\"label\">Køber</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Køberens retlige status</span><span class=\"text\">: </span><span class=\"dynamic-label\">Offentligretligt organ</span></section>\n            <section><span class=\"label\">Den ordregivende myndigheds aktivitet</span><span class=\"text\">: </span><span class=\"dynamic-label\">Uddannelse</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Gradient Power Amplifier System</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase 2 separate amplifiers with power supply units, each suited for\n                  driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human\n                  magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and\n                  hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time\n                  resolution of around a second for calculation of metabolic rates. To compensate for\n                  the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers\n                  must sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and\n                  &gt;130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance\n                  MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the\n                  lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers\n                  needs to be designed, built and equipped with safety measures so it can be approved\n                  for clinical use, even though CE labelling is not a requirement. Market research has\n                  shown that the only supplier of suitable gradient amplifiers that can fulfill the\n                  requirements above is IECO. Therefore, DTU intends to issue a purchase order to the\n                  company.</span></section>\n            <section><span class=\"label\">Identifikator for proceduren</span><span class=\"text\">: </span><span class=\"value\">469d8170-ce61-467b-b47e-17d7f753757d</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10316</span></section>\n            <section><span class=\"label\">Udbudsprocedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Udbud med forhandling uden forudgående offentliggørelse</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scannere</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\">A market survey was conducted using web search, AI queries and literature review.\n                     To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more\n                     gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must\n                     sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and &gt;130\n                     A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI\n                     with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%)\n                     during the lifetime of the carbon MRI signal, i.e., . 2 minutes. No vendor of MRI\n                     gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore,\n                     DTU intends to issue the purchase order to the company.</span></section>\n               <section><span class=\"label\">Retsgrundlag</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Direktiv 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Delkontrakt</span><section>5.1&nbsp;<span class=\"label\">Teknisk ID for delkontrakten</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Gradient Power Amplifier System</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase 2 separate amplifiers with power supply units, each suited for\n                  driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human\n                  magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and\n                  hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time\n                  resolution of around a second for calculation of metabolic rates. To compensate for\n                  the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers\n                  must sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and\n                  &gt;130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance\n                  MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the\n                  lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers\n                  needs to be designed, built and equipped with safety measures so it can be approved\n                  for clinical use, even though CE labelling is not a requirement. Market research has\n                  shown that the only supplier of suitable gradient amplifiers that can fulfill the\n                  requirements above is IECO. Therefore, DTU intends to issue a purchase order to the\n                  company.</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10316</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scannere</span></section>\n               <section><span class=\"label\">Mængde</span><span class=\"text\">: </span><span class=\"value\">2</span><span class=\"text\"> </span><span class=\"dynamic-label\">styk</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n               <section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Udbuddet er omfattet af aftalen om offentlige udbud (GPA)</span><span class=\"text\">: </span><span class=\"label\">ja</span></section>\n               <section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\">A market survey was conducted using web search, AI queries and literature review.\n                     To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more\n                     gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must\n                     sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and &gt;130\n                     A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI\n                     with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%)\n                     during the lifetime of the carbon MRI signal, i.e., . 2 minutes. No vendor of MRI\n                     gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore,\n                     DTU intends to issue the purchase order to the company.</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Yderligere oplysninger, mægling og gennemgang</span><section><span class=\"label\">Organisation med ansvar for mægling</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation med ansvar for klager</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Resultater</span><section><span class=\"label\">Værdien af alle kontrakter tildelt i denne bekendtgørelse</span><span class=\"text\">: </span><span class=\"value\">80.000</span><span class=\"text\"> </span><span class=\"label\">Euro</span></section>\n         <section><span class=\"label\">Direkte tildeling</span><span class=\"text\">:</span><section><span class=\"label\">Begrundelse for direkte tildeling</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kontrakten kan kun tildeles af en bestemt økonomisk aktør på grund af manglende konkurrence af tekniske årsager</span></section>\n            <section><span class=\"label\">Anden begrundelse</span><span class=\"text\">: </span><span class=\"value\">A market survey was conducted using web search, AI queries and literature review.\n                  To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more\n                  gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must\n                  sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and &gt;130\n                  A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI\n                  with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%)\n                  during the lifetime of the carbon MRI signal, i.e., 2 minutes. <br/>No vendor of MRI\n                  gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore,\n                  DTU intends to issue the purchase order to the company.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Resultat delkontrakt-ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Oplysninger om vinderne</span><section><span class=\"label\">Vinder</span><span class=\"text\">:</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">International Electric Company Oy</span></section>\n                  <section><span class=\"label\">Tilbud</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tilbud – Identifikator</span><span class=\"text\">: </span><span class=\"value\">10316 Gradient Power Amplifier System</span></section>\n                  <section><span class=\"label\">ID for delkontrakt eller gruppe af delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Kontraktoplysninger</span><span class=\"text\">:</span><section><span class=\"label\">Identifikator for kontrakten</span><span class=\"text\">: </span><span class=\"value\">10316 Gradient Power Amplifier System</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisationer</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">Per Christiansen</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">perach@dtu.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 45252525</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Køberprofil</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Køber</span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for klager</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for mægling</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">International Electric Company Oy</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">FI2189657-1</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Saahaajankatu 48</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Helsinki</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">00880</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Helsinki-Uusimaa</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">FI1B1</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Finland</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">Pasi Honkanen</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">info@ieco.fi</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+35897594470</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Tilbudsgiver</span></section>\n               <section><span class=\"label\">Vinder af disse delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norge</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Oplysninger om bekendtgørelsen</span><section><span class=\"label\">Bekendtgørelsens ID</span><span class=\"text\">: </span><span class=\"value\">d4222e47-1291-43bc-aec8-9ae47298833d</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Formulartype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Forudgående underretning om direkte tildeling</span></section>\n         <section><span class=\"label\">Bekendtgørelsestype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed</span></section>\n         <section><span class=\"label\">Afsendelsesdato for bekendtgørelsen</span><span class=\"text\">: </span><span class=\"value\">15-09-2025</span><span class=\"text\"> </span><span class=\"value\">09:39 +00:00</span></section>\n         <section><span class=\"label\">Dato for afsendelse af bekendtgørelsen (eSender)</span><span class=\"text\">: </span><span class=\"value\">15-09-2025</span><span class=\"text\"> </span><span class=\"value\">11:00 +00:00</span></section>\n         <section><span class=\"label\">Bekendtgørelsens officielle sprog</span><span class=\"text\">: </span><span class=\"dynamic-label\">engelsk</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Bekendtgørelsesnummer</span><span class=\"text\">: </span><span class=\"value\">00604726-2025</span></section>\n         <section><span class=\"label\">EUT-S-nummer</span><span class=\"text\">: </span><span class=\"value\">177/2025</span></section>\n         <section><span class=\"label\">Offentliggørelsesdato</span><span class=\"text\">: </span><span class=\"value\">16-09-2025</span></section>\n      </section>\n   </body>\n</html>","htmlEN":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Buyer</span><section>1.1&nbsp;<span class=\"label\">Buyer</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Legal type of the buyer</span><span class=\"text\">: </span><span class=\"dynamic-label\">Body governed by public law</span></section>\n            <section><span class=\"label\">Activity of the contracting authority</span><span class=\"text\">: </span><span class=\"dynamic-label\">Education</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Gradient Power Amplifier System</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase 2 separate amplifiers with power supply units, each suited for\n                  driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human\n                  magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and\n                  hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time\n                  resolution of around a second for calculation of metabolic rates. To compensate for\n                  the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers\n                  must sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and\n                  &gt;130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance\n                  MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the\n                  lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers\n                  needs to be designed, built and equipped with safety measures so it can be approved\n                  for clinical use, even though CE labelling is not a requirement. Market research has\n                  shown that the only supplier of suitable gradient amplifiers that can fulfill the\n                  requirements above is IECO. Therefore, DTU intends to issue a purchase order to the\n                  company.</span></section>\n            <section><span class=\"label\">Procedure identifier</span><span class=\"text\">: </span><span class=\"value\">469d8170-ce61-467b-b47e-17d7f753757d</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10316</span></section>\n            <section><span class=\"label\">Type of procedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Negotiated without prior call for competition</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scanners</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\">A market survey was conducted using web search, AI queries and literature review.\n                     To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more\n                     gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must\n                     sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and &gt;130\n                     A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI\n                     with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%)\n                     during the lifetime of the carbon MRI signal, i.e., . 2 minutes. No vendor of MRI\n                     gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore,\n                     DTU intends to issue the purchase order to the company.</span></section>\n               <section><span class=\"label\">Legal basis</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Directive 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Lot</span><section>5.1&nbsp;<span class=\"label\">Lot technical ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Gradient Power Amplifier System</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase 2 separate amplifiers with power supply units, each suited for\n                  driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human\n                  magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and\n                  hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time\n                  resolution of around a second for calculation of metabolic rates. To compensate for\n                  the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers\n                  must sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and\n                  &gt;130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance\n                  MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the\n                  lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers\n                  needs to be designed, built and equipped with safety measures so it can be approved\n                  for clinical use, even though CE labelling is not a requirement. Market research has\n                  shown that the only supplier of suitable gradient amplifiers that can fulfill the\n                  requirements above is IECO. Therefore, DTU intends to issue a purchase order to the\n                  company.</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10316</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scanners</span></section>\n               <section><span class=\"label\">Quantity</span><span class=\"text\">: </span><span class=\"value\">2</span><span class=\"text\"> </span><span class=\"dynamic-label\">piece</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n               <section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">The procurement is covered by the Government Procurement Agreement (GPA)</span><span class=\"text\">: </span><span class=\"label\">yes</span></section>\n               <section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\">A market survey was conducted using web search, AI queries and literature review.\n                     To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more\n                     gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must\n                     sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and &gt;130\n                     A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI\n                     with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%)\n                     during the lifetime of the carbon MRI signal, i.e., . 2 minutes. No vendor of MRI\n                     gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore,\n                     DTU intends to issue the purchase order to the company.</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Further information, mediation and review</span><section><span class=\"label\">Mediation organisation</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Review organisation</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Results</span><section><span class=\"label\">Value of all contracts awarded in this notice</span><span class=\"text\">: </span><span class=\"value\">80.000</span><span class=\"text\"> </span><span class=\"label\">Euro</span></section>\n         <section><span class=\"label\">Direct award</span><span class=\"text\">:</span><section><span class=\"label\">Justification for direct award</span><span class=\"text\">: </span><span class=\"dynamic-label\">The contract can be provided only by a particular economic operator because of an absence of competition for technical reasons</span></section>\n            <section><span class=\"label\">Other justification</span><span class=\"text\">: </span><span class=\"value\">A market survey was conducted using web search, AI queries and literature review.\n                  To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more\n                  gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must\n                  sustain peak voltages &gt;1000 V and peak currents &gt;260 A (at 20 kHz: &gt;1000 V and &gt;130\n                  A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI\n                  with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%)\n                  during the lifetime of the carbon MRI signal, i.e., 2 minutes. <br/>No vendor of MRI\n                  gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore,\n                  DTU intends to issue the purchase order to the company.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Result lot ldentifier</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Information about winners</span><section><span class=\"label\">Winner</span><span class=\"text\">:</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">International Electric Company Oy</span></section>\n                  <section><span class=\"label\">Tender</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tender identifier</span><span class=\"text\">: </span><span class=\"value\">10316 Gradient Power Amplifier System</span></section>\n                  <section><span class=\"label\">Identifier of lot or group of lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Contract information</span><span class=\"text\">:</span><section><span class=\"label\">Identifier of the contract</span><span class=\"text\">: </span><span class=\"value\">10316 Gradient Power Amplifier System</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisations</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">Per Christiansen</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">perach@dtu.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 45252525</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Buyer profile</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Buyer</span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Review organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Mediation organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">International Electric Company Oy</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">FI2189657-1</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Saahaajankatu 48</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Helsinki</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">00880</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Helsinki-Uusimaa</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">FI1B1</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Finland</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">Pasi Honkanen</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">info@ieco.fi</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+35897594470</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Tenderer</span></section>\n               <section><span class=\"label\">Winner of these lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norway</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Notice information</span><section><span class=\"label\">Notice identifier/version</span><span class=\"text\">: </span><span class=\"value\">d4222e47-1291-43bc-aec8-9ae47298833d</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Form type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Direct award preannouncement</span></section>\n         <section><span class=\"label\">Notice type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Voluntary ex-ante transparency notice</span></section>\n         <section><span class=\"label\">Notice dispatch date</span><span class=\"text\">: </span><span class=\"value\">15-09-2025</span><span class=\"text\"> </span><span class=\"value\">09:39 +00:00</span></section>\n         <section><span class=\"label\">Notice dispatch date (eSender)</span><span class=\"text\">: </span><span class=\"value\">15-09-2025</span><span class=\"text\"> </span><span class=\"value\">11:00 +00:00</span></section>\n         <section><span class=\"label\">Languages in which this notice is officially available</span><span class=\"text\">: </span><span class=\"dynamic-label\">English</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Notice publication number</span><span class=\"text\">: </span><span class=\"value\">00604726-2025</span></section>\n         <section><span class=\"label\">OJ S issue number</span><span class=\"text\">: </span><span class=\"value\">177/2025</span></section>\n         <section><span class=\"label\">Publication date</span><span class=\"text\">: </span><span class=\"value\">16-09-2025</span></section>\n      </section>\n   </body>\n</html>","opsummeringDA":{"card":{"titel":"Gradient Power Amplifier System","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2025-09-16+02:00","cpvKode":"38520000","cpvTitel":"Scannere","formulartype":"Forudgående underretning om direkte tildeling","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU needs to purchase 2 separate amplifiers with power supply units, each suited for driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. To compensate for the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers must sustain peak voltages >1000 V and peak currents  >260 A  (at 20 kHz: >1000 V and >130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers needs to be designed, built and equipped with safety measures so it can be approved for clinical use, even though CE labelling is not a requirement. Market research has shown that the only supplier of suitable gradient amplifiers that can fulfill the requirements above is IECO. Therefore, DTU intends to issue a purchase order to the company.","bkSubTypeKode":"25","bkSubType":"Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed – det generelle direktiv","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]},"opsummeringEN":{"card":{"titel":"Gradient Power Amplifier System","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2025-09-16+02:00","cpvKode":"38520000","cpvTitel":"Scanners","formulartype":"Direct award preannouncement","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU needs to purchase 2 separate amplifiers with power supply units, each suited for driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. To compensate for the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers must sustain peak voltages >1000 V and peak currents  >260 A  (at 20 kHz: >1000 V and >130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers needs to be designed, built and equipped with safety measures so it can be approved for clinical use, even though CE labelling is not a requirement. Market research has shown that the only supplier of suitable gradient amplifiers that can fulfill the requirements above is IECO. Therefore, DTU intends to issue a purchase order to the company.","bkSubTypeKode":"25","bkSubType":"Voluntary ex-ante transparency notice – general directive","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]}}