{"bekendtgoerelseNoegle":{"noticeId":{"value":"ccc15b04-94f0-46c9-ad30-be9f357bf6cd"},"noticeVersion":{"value":"01"},"noticePublicationNumber":{"value":"00656036-2026"}},"htmlDA":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Køber</span><section>1.1&nbsp;<span class=\"label\">Køber</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Køberens retlige status</span><span class=\"text\">: </span><span class=\"dynamic-label\">Offentligretligt organ</span></section>\n            <section><span class=\"label\">Den ordregivende myndigheds aktivitet</span><span class=\"text\">: </span><span class=\"dynamic-label\">Uddannelse</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O and CH₄\n                  fluxes</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU requires the acquisition of one complete eddy covariance measurement station for\n                  continuous, long-term monitoring of exchanges of carbon dioxide (CO₂), methane (CH₄),\n                  water vapour, heat, and momentum between an apple orchard and the atmosphere. The\n                  system will be used for research on climate impacts, greenhouse gas balances, carbon\n                  sequestration, water use, and sustainable agricultural production. <br/><br/>The acquisition\n                  comprises a fully integrated field measurement station capable of operating autonomously\n                  under outdoor conditions throughout the year and generating high-frequency measurements\n                  suitable for eddy covariance flux calculations. <br/><br/>The acquisition includes:\n                  <br/>• 1 three-dimensional sonic anemometer for high-frequency measurement of wind\n                  speed and wind direction. <br/>• 1 open-path carbon dioxide and water vapour analyser\n                  for continuous measurement of atmospheric CO₂ and H₂O concentrations. <br/>• 1 open-path\n                  methane analyser for continuous measurement of atmospheric CH₄ concentrations. <br/>•\n                  1 integrated data acquisition, processing, storage, and communication system for synchronization,\n                  logging, quality control, and transfer of measurement data. <br/>• 1 meteorological\n                  measurement package comprising sensors for air temperature, relative humidity, precipitation,\n                  solar radiation, photosynthetically active radiation (PAR), net radiation, soil moisture,\n                  soil temperature, and soil heat flux. <br/>• 1 backup power and data retention system\n                  to ensure continued operation and prevent data loss during temporary interruptions.\n                  <br/>• 1 software package for data processing, quality assurance, visualization, footprint\n                  analysis, gap filling, and management of eddy covariance data. <br/>• 1 galvanized\n                  lattice measurement tower with a height of approximately 12 m, including foundation,\n                  mounting hardware, transport, and installation. The tower is required to position\n                  sensors above the orchard canopy and provide safe access for installation and maintenance.\n                  <br/>• 1 solar power system comprising photovoltaic panels, batteries, charge controller,\n                  mounting hardware, cabling, and associated electrical components required for autonomous\n                  operation at a field site without permanent grid connection.<br/>• All cables, communication\n                  equipment, sensor mounts, brackets, connectors, and<br/>accessories required for a\n                  complete operational system.<br/><br/>DTU requires a complete Eddy Covariance system\n                  for continuous measurement of ecosystematmosphere exchanges of carbon dioxide (CO₂),\n                  water vapour (H₂O), methane (CH₄) and energy in an experimental apple orchard. The\n                  system must provide high-frequency measurements, robust long-term field operation,\n                  standardized data processing and compatibility with established international flux\n                  research infrastructures.<br/><br/>A market assessment was performed to identify suppliers\n                  capable of delivering a complete Eddy Covariance solution that meets the scientific\n                  and technical requirements of the project. Suppliers investigated included LI-COR\n                  Biosciences, Campbell Scientific, Picarro and Los Gatos Research. Several suppliers\n                  can provide systems for CO₂ and H₂O flux measurements. However, LI-COR is the only\n                  supplier identified that can provide the required integrated Eddy Covariance<br/>platform\n                  including an open-path methane analyser, synchronized measurement architecture, integrated\n                  real-time flux processing and established compatibility with major international flux\n                  monitoring networks. <br/><br/>The proposed system includes the LI-7700 open-path\n                  methane analyser integrated with the LI-7900 EddyFlux platform. According to the supplier\n                  documentation, LI-COR is the only supplier<br/>offering an open-path methane Eddy\n                  Covariance system with extensive field validation and long-term scientific use. The\n                  system further provides microsecond-level synchronization of instruments through Precision\n                  Time Protocol (PTP) and GPS-based clock control, which are essential for accurate\n                  flux calculations and data consistency. The system includes EddyPro, a widely adopted\n                  Eddy Covariance processing software used by international research<br/>infrastructures\n                  and flux networks, including ICOS. The software environment, data handling capabilities\n                  and compatibility with established network requirements are essential for ensuring\n                  data quality, comparability and long-term usability of the measurements generated\n                  within the project.<br/>The Eddy Covariance tower will be installed as temporary research\n                  infrastructure and will be dismantled and relocated to other research sites upon completion\n                  of the project. The tower and instrumentation therefore constitute reusable scientific\n                  infrastructure. Based on the market assessment, no reasonable alternative supplier\n                  was identified that could provide an equivalent integrated solution meeting all technical\n                  requirements for open-path methane Eddy Covariance<br/>measurements, synchronization,\n                  processing and compatibility with international flux research infrastructures and\n                  DTU therefore intends to award the contract to LI-COR Biosciences GmbH.</span></section>\n            <section><span class=\"label\">Identifikator for proceduren</span><span class=\"text\">: </span><span class=\"value\">c4bc9f54-f00e-460c-aa9b-6a81488581bd</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">11265</span></section>\n            <section><span class=\"label\">Udbudsprocedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Udbud med forhandling uden forudgående offentliggørelse</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38290000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Instrumenter og indretninger til landmåling, hydrografi, oceanografi og hydrologi</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38300000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Måleudstyr</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Retsgrundlag</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Direktiv 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Delkontrakt</span><section>5.1&nbsp;<span class=\"label\">Delkontrakt</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O and CH₄\n                  fluxes</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU requires the acquisition of one complete eddy covariance measurement station for\n                  continuous, long-term monitoring of exchanges of carbon dioxide (CO₂), methane (CH₄),\n                  water vapour, heat, and momentum between an apple orchard and the atmosphere. The\n                  system will be used for research on climate impacts, greenhouse gas balances, carbon\n                  sequestration, water use, and sustainable agricultural production. <br/><br/>The acquisition\n                  comprises a fully integrated field measurement station capable of operating autonomously\n                  under outdoor conditions throughout the year and generating high-frequency measurements\n                  suitable for eddy covariance flux calculations. <br/><br/>The acquisition includes:\n                  <br/>• 1 three-dimensional sonic anemometer for high-frequency measurement of wind\n                  speed and wind direction. <br/>• 1 open-path carbon dioxide and water vapour analyser\n                  for continuous measurement of atmospheric CO₂ and H₂O concentrations. <br/>• 1 open-path\n                  methane analyser for continuous measurement of atmospheric CH₄ concentrations. <br/>•\n                  1 integrated data acquisition, processing, storage, and communication system for synchronization,\n                  logging, quality control, and transfer of measurement data. <br/>• 1 meteorological\n                  measurement package comprising sensors for air temperature, relative humidity, precipitation,\n                  solar radiation, photosynthetically active radiation (PAR), net radiation, soil moisture,\n                  soil temperature, and soil heat flux. <br/>• 1 backup power and data retention system\n                  to ensure continued operation and prevent data loss during temporary interruptions.\n                  <br/>• 1 software package for data processing, quality assurance, visualization, footprint\n                  analysis, gap filling, and management of eddy covariance data. <br/>• 1 galvanized\n                  lattice measurement tower with a height of approximately 12 m, including foundation,\n                  mounting hardware, transport, and installation. The tower is required to position\n                  sensors above the orchard canopy and provide safe access for installation and maintenance.\n                  <br/>• 1 solar power system comprising photovoltaic panels, batteries, charge controller,\n                  mounting hardware, cabling, and associated electrical components required for autonomous\n                  operation at a field site without permanent grid connection.<br/>• All cables, communication\n                  equipment, sensor mounts, brackets, connectors, and<br/>accessories required for a\n                  complete operational system.<br/><br/>DTU requires a complete Eddy Covariance system\n                  for continuous measurement of ecosystematmosphere exchanges of carbon dioxide (CO₂),\n                  water vapour (H₂O), methane (CH₄) and energy in an experimental apple orchard. The\n                  system must provide high-frequency measurements, robust long-term field operation,\n                  standardized data processing and compatibility with established international flux\n                  research infrastructures.<br/><br/>A market assessment was performed to identify suppliers\n                  capable of delivering a complete Eddy Covariance solution that meets the scientific\n                  and technical requirements of the project. Suppliers investigated included LI-COR\n                  Biosciences, Campbell Scientific, Picarro and Los Gatos Research. Several suppliers\n                  can provide systems for CO₂ and H₂O flux measurements. However, LI-COR is the only\n                  supplier identified that can provide the required integrated Eddy Covariance<br/>platform\n                  including an open-path methane analyser, synchronized measurement architecture, integrated\n                  real-time flux processing and established compatibility with major international flux\n                  monitoring networks. <br/><br/>The proposed system includes the LI-7700 open-path\n                  methane analyser integrated with the LI-7900 EddyFlux platform. According to the supplier\n                  documentation, LI-COR is the only supplier<br/>offering an open-path methane Eddy\n                  Covariance system with extensive field validation and long-term scientific use. The\n                  system further provides microsecond-level synchronization of instruments through Precision\n                  Time Protocol (PTP) and GPS-based clock control, which are essential for accurate\n                  flux calculations and data consistency. The system includes EddyPro, a widely adopted\n                  Eddy Covariance processing software used by international research<br/>infrastructures\n                  and flux networks, including ICOS. The software environment, data handling capabilities\n                  and compatibility with established network requirements are essential for ensuring\n                  data quality, comparability and long-term usability of the measurements generated\n                  within the project.<br/>The Eddy Covariance tower will be installed as temporary research\n                  infrastructure and will be dismantled and relocated to other research sites upon completion\n                  of the project. The tower and instrumentation therefore constitute reusable scientific\n                  infrastructure. Based on the market assessment, no reasonable alternative supplier\n                  was identified that could provide an equivalent integrated solution meeting all technical\n                  requirements for open-path methane Eddy Covariance<br/>measurements, synchronization,\n                  processing and compatibility with international flux research infrastructures and\n                  DTU therefore intends to award the contract to LI-COR Biosciences GmbH.</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">11265</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38290000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Instrumenter og indretninger til landmåling, hydrografi, oceanografi og hydrologi</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38300000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Måleudstyr</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n               <section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Udbuddet er omfattet af aftalen om offentlige udbud (GPA)</span><span class=\"text\">: </span><span class=\"label\">nej</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Yderligere oplysninger, mægling og gennemgang</span><section><span class=\"label\">Organisation med ansvar for mægling</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation med ansvar for klager</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Resultater</span><section><span class=\"label\">Direkte tildeling</span><span class=\"text\">:</span><section><span class=\"label\">Begrundelse for direkte tildeling</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kontrakten kan kun tildeles af en bestemt økonomisk aktør på grund af manglende konkurrence af tekniske årsager</span></section>\n            <section><span class=\"label\">Anden begrundelse</span><span class=\"text\">: </span><span class=\"value\">DTU requires a complete Eddy Covariance system for continuous measurement of ecosystematmosphere\n                  exchanges of carbon dioxide (CO₂), water vapour (H₂O), methane (CH₄) and energy in\n                  an experimental apple orchard. The system must provide high-frequency measurements,\n                  robust long-term field operation, standardized data processing and compatibility with\n                  established international flux research infrastructures.<br/>A market assessment was\n                  performed to identify suppliers capable of delivering a complete Eddy Covariance solution\n                  that meets the scientific and technical requirements of the project. Suppliers investigated\n                  included LI-COR Biosciences, Campbell Scientific, Picarro and Los Gatos Research.\n                  Several suppliers can provide systems for CO₂ and H₂O flux measurements. However,\n                  LI-COR is the only supplier identified that can provide the required integrated Eddy\n                  Covariance<br/>platform including an open-path methane analyser, synchronized measurement\n                  architecture, integrated real-time flux processing and established compatibility with\n                  major international flux monitoring networks.<br/>The proposed system includes the\n                  LI-7700 open-path methane analyser integrated with the LI-7900 EddyFlux platform.\n                  According to the supplier documentation, LI-COR is the only supplier offering an open-path\n                  methane Eddy Covariance system with extensive field validation and long-term scientific\n                  use. The system further provides microsecond-level synchronization of<br/>instruments\n                  through Precision Time Protocol (PTP) and GPS-based clock control, which are essential\n                  for accurate flux calculations and data consistency. The system includes EddyPro,\n                  a widely adopted Eddy Covariance processing software used by international research\n                  infrastructures and flux networks, including ICOS. The software environment, data\n                  handling capabilities and compatibility with established network requirements are\n                  essential for ensuring data quality, comparability and long-term usability of the\n                  measurements generated within the<br/>project. The Eddy Covariance tower will be installed\n                  as temporary research infrastructure and will be dismantled and relocated to other\n                  research sites upon completion of the project. The tower and instrumentation therefore\n                  constitute reusable scientific infrastructure. Based on the market assessment, no\n                  reasonable alternative supplier was identified that could provide an equivalent integrated\n                  solution meeting all technical requirements for open-path methane Eddy Covariance\n                  measurements, synchronization, processing and compatibility with international flux\n                  research infrastructures and DTU therefore intends to award the contract to LI-COR\n                  Biosciences GmbH at the price of EUR 104,000.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Resultat delkontrakt-ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Oplysninger om vinderne</span><section><span class=\"label\">Vinder</span><span class=\"text\">:</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">LI-COR Biosciences GmbH</span></section>\n                  <section><span class=\"label\">Tilbud</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tilbud – Identifikator</span><span class=\"text\">: </span><span class=\"value\">11265 - Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O\n                        and CH₄ fluxes</span></section>\n                  <section><span class=\"label\">ID for delkontrakt eller gruppe af delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Kontraktoplysninger</span><span class=\"text\">:</span><section><span class=\"label\">Identifikator for kontrakten</span><span class=\"text\">: </span><span class=\"value\">11265 - Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O\n                           and CH₄ fluxes, 11265</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisationer</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">Lise Nørhaven</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">lisno@dtu.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 93510929</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Køberprofil</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Køber</span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for klager</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for mægling</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">LI-COR Biosciences GmbH</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">DE213054107</span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Bad Homburg</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">61352</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Hochtaunuskreis</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DE718</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tyskland</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Tilbudsgiver</span></section>\n               <section><span class=\"label\">Vinder af disse delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norge</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Oplysninger om bekendtgørelsen</span><section><span class=\"label\">Bekendtgørelsens ID</span><span class=\"text\">: </span><span class=\"value\">ccc15b04-94f0-46c9-ad30-be9f357bf6cd</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Formulartype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Forudgående underretning om direkte tildeling</span></section>\n         <section><span class=\"label\">Bekendtgørelsestype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed</span></section>\n         <section><span class=\"label\">Afsendelsesdato for bekendtgørelsen</span><span class=\"text\">: </span><span class=\"value\">22-09-2026</span><span class=\"text\"> </span><span class=\"value\">08:29 +00:00</span></section>\n         <section><span class=\"label\">Dato for afsendelse af bekendtgørelsen (eSender)</span><span class=\"text\">: </span><span class=\"value\">22-09-2026</span><span class=\"text\"> </span><span class=\"value\">09:00 +00:00</span></section>\n         <section><span class=\"label\">Bekendtgørelsens officielle sprog</span><span class=\"text\">: </span><span class=\"dynamic-label\">dansk</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Bekendtgørelsesnummer</span><span class=\"text\">: </span><span class=\"value\">00656036-2026</span></section>\n         <section><span class=\"label\">EUT-S-nummer</span><span class=\"text\">: </span><span class=\"value\">184/2026</span></section>\n         <section><span class=\"label\">Offentliggørelsesdato</span><span class=\"text\">: </span><span class=\"value\">23-09-2026</span></section>\n      </section>\n   </body>\n</html>","htmlEN":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Buyer</span><section>1.1&nbsp;<span class=\"label\">Buyer</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Legal type of the buyer</span><span class=\"text\">: </span><span class=\"dynamic-label\">Body governed by public law</span></section>\n            <section><span class=\"label\">Activity of the contracting authority</span><span class=\"text\">: </span><span class=\"dynamic-label\">Education</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O and CH₄\n                  fluxes</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU requires the acquisition of one complete eddy covariance measurement station for\n                  continuous, long-term monitoring of exchanges of carbon dioxide (CO₂), methane (CH₄),\n                  water vapour, heat, and momentum between an apple orchard and the atmosphere. The\n                  system will be used for research on climate impacts, greenhouse gas balances, carbon\n                  sequestration, water use, and sustainable agricultural production. <br/><br/>The acquisition\n                  comprises a fully integrated field measurement station capable of operating autonomously\n                  under outdoor conditions throughout the year and generating high-frequency measurements\n                  suitable for eddy covariance flux calculations. <br/><br/>The acquisition includes:\n                  <br/>• 1 three-dimensional sonic anemometer for high-frequency measurement of wind\n                  speed and wind direction. <br/>• 1 open-path carbon dioxide and water vapour analyser\n                  for continuous measurement of atmospheric CO₂ and H₂O concentrations. <br/>• 1 open-path\n                  methane analyser for continuous measurement of atmospheric CH₄ concentrations. <br/>•\n                  1 integrated data acquisition, processing, storage, and communication system for synchronization,\n                  logging, quality control, and transfer of measurement data. <br/>• 1 meteorological\n                  measurement package comprising sensors for air temperature, relative humidity, precipitation,\n                  solar radiation, photosynthetically active radiation (PAR), net radiation, soil moisture,\n                  soil temperature, and soil heat flux. <br/>• 1 backup power and data retention system\n                  to ensure continued operation and prevent data loss during temporary interruptions.\n                  <br/>• 1 software package for data processing, quality assurance, visualization, footprint\n                  analysis, gap filling, and management of eddy covariance data. <br/>• 1 galvanized\n                  lattice measurement tower with a height of approximately 12 m, including foundation,\n                  mounting hardware, transport, and installation. The tower is required to position\n                  sensors above the orchard canopy and provide safe access for installation and maintenance.\n                  <br/>• 1 solar power system comprising photovoltaic panels, batteries, charge controller,\n                  mounting hardware, cabling, and associated electrical components required for autonomous\n                  operation at a field site without permanent grid connection.<br/>• All cables, communication\n                  equipment, sensor mounts, brackets, connectors, and<br/>accessories required for a\n                  complete operational system.<br/><br/>DTU requires a complete Eddy Covariance system\n                  for continuous measurement of ecosystematmosphere exchanges of carbon dioxide (CO₂),\n                  water vapour (H₂O), methane (CH₄) and energy in an experimental apple orchard. The\n                  system must provide high-frequency measurements, robust long-term field operation,\n                  standardized data processing and compatibility with established international flux\n                  research infrastructures.<br/><br/>A market assessment was performed to identify suppliers\n                  capable of delivering a complete Eddy Covariance solution that meets the scientific\n                  and technical requirements of the project. Suppliers investigated included LI-COR\n                  Biosciences, Campbell Scientific, Picarro and Los Gatos Research. Several suppliers\n                  can provide systems for CO₂ and H₂O flux measurements. However, LI-COR is the only\n                  supplier identified that can provide the required integrated Eddy Covariance<br/>platform\n                  including an open-path methane analyser, synchronized measurement architecture, integrated\n                  real-time flux processing and established compatibility with major international flux\n                  monitoring networks. <br/><br/>The proposed system includes the LI-7700 open-path\n                  methane analyser integrated with the LI-7900 EddyFlux platform. According to the supplier\n                  documentation, LI-COR is the only supplier<br/>offering an open-path methane Eddy\n                  Covariance system with extensive field validation and long-term scientific use. The\n                  system further provides microsecond-level synchronization of instruments through Precision\n                  Time Protocol (PTP) and GPS-based clock control, which are essential for accurate\n                  flux calculations and data consistency. The system includes EddyPro, a widely adopted\n                  Eddy Covariance processing software used by international research<br/>infrastructures\n                  and flux networks, including ICOS. The software environment, data handling capabilities\n                  and compatibility with established network requirements are essential for ensuring\n                  data quality, comparability and long-term usability of the measurements generated\n                  within the project.<br/>The Eddy Covariance tower will be installed as temporary research\n                  infrastructure and will be dismantled and relocated to other research sites upon completion\n                  of the project. The tower and instrumentation therefore constitute reusable scientific\n                  infrastructure. Based on the market assessment, no reasonable alternative supplier\n                  was identified that could provide an equivalent integrated solution meeting all technical\n                  requirements for open-path methane Eddy Covariance<br/>measurements, synchronization,\n                  processing and compatibility with international flux research infrastructures and\n                  DTU therefore intends to award the contract to LI-COR Biosciences GmbH.</span></section>\n            <section><span class=\"label\">Procedure identifier</span><span class=\"text\">: </span><span class=\"value\">c4bc9f54-f00e-460c-aa9b-6a81488581bd</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">11265</span></section>\n            <section><span class=\"label\">Type of procedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Negotiated without prior call for competition</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38290000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Surveying, hydrographic, oceanographic and hydrological instruments and appliances</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38300000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Measuring instruments</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">Legal basis</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Directive 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Lot</span><section>5.1&nbsp;<span class=\"label\">Lot</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O and CH₄\n                  fluxes</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU requires the acquisition of one complete eddy covariance measurement station for\n                  continuous, long-term monitoring of exchanges of carbon dioxide (CO₂), methane (CH₄),\n                  water vapour, heat, and momentum between an apple orchard and the atmosphere. The\n                  system will be used for research on climate impacts, greenhouse gas balances, carbon\n                  sequestration, water use, and sustainable agricultural production. <br/><br/>The acquisition\n                  comprises a fully integrated field measurement station capable of operating autonomously\n                  under outdoor conditions throughout the year and generating high-frequency measurements\n                  suitable for eddy covariance flux calculations. <br/><br/>The acquisition includes:\n                  <br/>• 1 three-dimensional sonic anemometer for high-frequency measurement of wind\n                  speed and wind direction. <br/>• 1 open-path carbon dioxide and water vapour analyser\n                  for continuous measurement of atmospheric CO₂ and H₂O concentrations. <br/>• 1 open-path\n                  methane analyser for continuous measurement of atmospheric CH₄ concentrations. <br/>•\n                  1 integrated data acquisition, processing, storage, and communication system for synchronization,\n                  logging, quality control, and transfer of measurement data. <br/>• 1 meteorological\n                  measurement package comprising sensors for air temperature, relative humidity, precipitation,\n                  solar radiation, photosynthetically active radiation (PAR), net radiation, soil moisture,\n                  soil temperature, and soil heat flux. <br/>• 1 backup power and data retention system\n                  to ensure continued operation and prevent data loss during temporary interruptions.\n                  <br/>• 1 software package for data processing, quality assurance, visualization, footprint\n                  analysis, gap filling, and management of eddy covariance data. <br/>• 1 galvanized\n                  lattice measurement tower with a height of approximately 12 m, including foundation,\n                  mounting hardware, transport, and installation. The tower is required to position\n                  sensors above the orchard canopy and provide safe access for installation and maintenance.\n                  <br/>• 1 solar power system comprising photovoltaic panels, batteries, charge controller,\n                  mounting hardware, cabling, and associated electrical components required for autonomous\n                  operation at a field site without permanent grid connection.<br/>• All cables, communication\n                  equipment, sensor mounts, brackets, connectors, and<br/>accessories required for a\n                  complete operational system.<br/><br/>DTU requires a complete Eddy Covariance system\n                  for continuous measurement of ecosystematmosphere exchanges of carbon dioxide (CO₂),\n                  water vapour (H₂O), methane (CH₄) and energy in an experimental apple orchard. The\n                  system must provide high-frequency measurements, robust long-term field operation,\n                  standardized data processing and compatibility with established international flux\n                  research infrastructures.<br/><br/>A market assessment was performed to identify suppliers\n                  capable of delivering a complete Eddy Covariance solution that meets the scientific\n                  and technical requirements of the project. Suppliers investigated included LI-COR\n                  Biosciences, Campbell Scientific, Picarro and Los Gatos Research. Several suppliers\n                  can provide systems for CO₂ and H₂O flux measurements. However, LI-COR is the only\n                  supplier identified that can provide the required integrated Eddy Covariance<br/>platform\n                  including an open-path methane analyser, synchronized measurement architecture, integrated\n                  real-time flux processing and established compatibility with major international flux\n                  monitoring networks. <br/><br/>The proposed system includes the LI-7700 open-path\n                  methane analyser integrated with the LI-7900 EddyFlux platform. According to the supplier\n                  documentation, LI-COR is the only supplier<br/>offering an open-path methane Eddy\n                  Covariance system with extensive field validation and long-term scientific use. The\n                  system further provides microsecond-level synchronization of instruments through Precision\n                  Time Protocol (PTP) and GPS-based clock control, which are essential for accurate\n                  flux calculations and data consistency. The system includes EddyPro, a widely adopted\n                  Eddy Covariance processing software used by international research<br/>infrastructures\n                  and flux networks, including ICOS. The software environment, data handling capabilities\n                  and compatibility with established network requirements are essential for ensuring\n                  data quality, comparability and long-term usability of the measurements generated\n                  within the project.<br/>The Eddy Covariance tower will be installed as temporary research\n                  infrastructure and will be dismantled and relocated to other research sites upon completion\n                  of the project. The tower and instrumentation therefore constitute reusable scientific\n                  infrastructure. Based on the market assessment, no reasonable alternative supplier\n                  was identified that could provide an equivalent integrated solution meeting all technical\n                  requirements for open-path methane Eddy Covariance<br/>measurements, synchronization,\n                  processing and compatibility with international flux research infrastructures and\n                  DTU therefore intends to award the contract to LI-COR Biosciences GmbH.</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">11265</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38290000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Surveying, hydrographic, oceanographic and hydrological instruments and appliances</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38300000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Measuring instruments</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n               <section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">The procurement is covered by the Government Procurement Agreement (GPA)</span><span class=\"text\">: </span><span class=\"label\">no</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Further information, mediation and review</span><section><span class=\"label\">Mediation organisation</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Review organisation</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Results</span><section><span class=\"label\">Direct award</span><span class=\"text\">:</span><section><span class=\"label\">Justification for direct award</span><span class=\"text\">: </span><span class=\"dynamic-label\">The contract can be provided only by a particular economic operator because of an absence of competition for technical reasons</span></section>\n            <section><span class=\"label\">Other justification</span><span class=\"text\">: </span><span class=\"value\">DTU requires a complete Eddy Covariance system for continuous measurement of ecosystematmosphere\n                  exchanges of carbon dioxide (CO₂), water vapour (H₂O), methane (CH₄) and energy in\n                  an experimental apple orchard. The system must provide high-frequency measurements,\n                  robust long-term field operation, standardized data processing and compatibility with\n                  established international flux research infrastructures.<br/>A market assessment was\n                  performed to identify suppliers capable of delivering a complete Eddy Covariance solution\n                  that meets the scientific and technical requirements of the project. Suppliers investigated\n                  included LI-COR Biosciences, Campbell Scientific, Picarro and Los Gatos Research.\n                  Several suppliers can provide systems for CO₂ and H₂O flux measurements. However,\n                  LI-COR is the only supplier identified that can provide the required integrated Eddy\n                  Covariance<br/>platform including an open-path methane analyser, synchronized measurement\n                  architecture, integrated real-time flux processing and established compatibility with\n                  major international flux monitoring networks.<br/>The proposed system includes the\n                  LI-7700 open-path methane analyser integrated with the LI-7900 EddyFlux platform.\n                  According to the supplier documentation, LI-COR is the only supplier offering an open-path\n                  methane Eddy Covariance system with extensive field validation and long-term scientific\n                  use. The system further provides microsecond-level synchronization of<br/>instruments\n                  through Precision Time Protocol (PTP) and GPS-based clock control, which are essential\n                  for accurate flux calculations and data consistency. The system includes EddyPro,\n                  a widely adopted Eddy Covariance processing software used by international research\n                  infrastructures and flux networks, including ICOS. The software environment, data\n                  handling capabilities and compatibility with established network requirements are\n                  essential for ensuring data quality, comparability and long-term usability of the\n                  measurements generated within the<br/>project. The Eddy Covariance tower will be installed\n                  as temporary research infrastructure and will be dismantled and relocated to other\n                  research sites upon completion of the project. The tower and instrumentation therefore\n                  constitute reusable scientific infrastructure. Based on the market assessment, no\n                  reasonable alternative supplier was identified that could provide an equivalent integrated\n                  solution meeting all technical requirements for open-path methane Eddy Covariance\n                  measurements, synchronization, processing and compatibility with international flux\n                  research infrastructures and DTU therefore intends to award the contract to LI-COR\n                  Biosciences GmbH at the price of EUR 104,000.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Result lot identifier</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Information about winners</span><section><span class=\"label\">Winner</span><span class=\"text\">:</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">LI-COR Biosciences GmbH</span></section>\n                  <section><span class=\"label\">Tender</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tender identifier</span><span class=\"text\">: </span><span class=\"value\">11265 - Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O\n                        and CH₄ fluxes</span></section>\n                  <section><span class=\"label\">Identifier of lot or group of lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Contract information</span><span class=\"text\">:</span><section><span class=\"label\">Identifier of the contract</span><span class=\"text\">: </span><span class=\"value\">11265 - Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O\n                           and CH₄ fluxes, 11265</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisations</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">Lise Nørhaven</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">lisno@dtu.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 93510929</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Buyer profile</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Buyer</span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Review organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Mediation organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">LI-COR Biosciences GmbH</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">DE213054107</span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Bad Homburg</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">61352</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Hochtaunuskreis</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DE718</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Germany</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Tenderer</span></section>\n               <section><span class=\"label\">Winner of these lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norway</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Notice information</span><section><span class=\"label\">Notice identifier/version</span><span class=\"text\">: </span><span class=\"value\">ccc15b04-94f0-46c9-ad30-be9f357bf6cd</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Form type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Direct award preannouncement</span></section>\n         <section><span class=\"label\">Notice type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Voluntary ex-ante transparency notice</span></section>\n         <section><span class=\"label\">Notice dispatch date</span><span class=\"text\">: </span><span class=\"value\">22-09-2026</span><span class=\"text\"> </span><span class=\"value\">08:29 +00:00</span></section>\n         <section><span class=\"label\">Notice dispatch date (eSender)</span><span class=\"text\">: </span><span class=\"value\">22-09-2026</span><span class=\"text\"> </span><span class=\"value\">09:00 +00:00</span></section>\n         <section><span class=\"label\">Languages in which this notice is officially available</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danish</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Notice publication number</span><span class=\"text\">: </span><span class=\"value\">00656036-2026</span></section>\n         <section><span class=\"label\">OJ S issue number</span><span class=\"text\">: </span><span class=\"value\">184/2026</span></section>\n         <section><span class=\"label\">Publication date</span><span class=\"text\">: </span><span class=\"value\">23-09-2026</span></section>\n      </section>\n   </body>\n</html>","opsummeringDA":{"card":{"titel":"Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O and CH₄ fluxes","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2026-09-23+02:00","cpvKode":"38290000","cpvTitel":"Instrumenter og indretninger til landmåling, hydrografi, oceanografi og hydrologi","formulartype":"Forudgående underretning om direkte tildeling","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU requires the acquisition of one complete eddy covariance measurement station for continuous, long-term monitoring of exchanges of carbon dioxide (CO₂), methane (CH₄), water vapour, heat, and momentum between an apple orchard and the atmosphere. The system will be used for research on climate impacts, greenhouse gas balances, carbon sequestration, water use, and sustainable agricultural production.  \n\nThe acquisition comprises a fully integrated field measurement station capable of operating autonomously under outdoor conditions throughout the year and generating high-frequency measurements suitable for eddy covariance flux calculations.  \n\nThe acquisition includes: \n• 1 three-dimensional sonic anemometer for high-frequency measurement of wind speed and wind direction. \n• 1 open-path carbon dioxide and water vapour analyser for continuous measurement of atmospheric CO₂ and H₂O concentrations. \n• 1 open-path methane analyser for continuous measurement of atmospheric CH₄ concentrations. \n• 1 integrated data acquisition, processing, storage, and communication system for synchronization, logging, quality control, and transfer of measurement data. \n• 1 meteorological measurement package comprising sensors for air temperature, relative humidity, precipitation, solar radiation, photosynthetically active radiation (PAR), net radiation, soil moisture, soil temperature, and soil heat flux. \n• 1 backup power and data retention system to ensure continued operation and prevent data loss during temporary interruptions. \n• 1 software package for data processing, quality assurance, visualization, footprint analysis, gap filling, and management of eddy covariance data. \n• 1 galvanized lattice measurement tower with a height of approximately 12 m, including foundation, mounting hardware, transport, and installation. The tower is required to position sensors above the orchard canopy and provide safe access for installation and maintenance. \n• 1 solar power system comprising photovoltaic panels, batteries, charge controller, mounting hardware, cabling, and associated electrical components required for autonomous operation at a field site without permanent grid connection.\n• All cables, communication equipment, sensor mounts, brackets, connectors, and\naccessories required for a complete operational system.\n\nDTU requires a complete Eddy Covariance system for continuous measurement of ecosystematmosphere exchanges of carbon dioxide (CO₂), water vapour (H₂O), methane (CH₄) and energy in an experimental apple orchard. The system must provide high-frequency measurements, robust long-term field operation, standardized data processing and compatibility with established international flux research infrastructures.\n\nA market assessment was performed to identify suppliers capable of delivering a complete Eddy Covariance solution that meets the scientific and technical requirements of the project. Suppliers investigated included LI-COR Biosciences, Campbell Scientific, Picarro and Los Gatos Research. Several suppliers can provide systems for CO₂ and H₂O flux measurements. However, LI-COR is the only supplier identified that can provide the required integrated Eddy Covariance\nplatform including an open-path methane analyser, synchronized measurement architecture, integrated real-time flux processing and established compatibility with major international flux monitoring networks. \n\nThe proposed system includes the LI-7700 open-path methane analyser integrated with the LI-7900 EddyFlux platform. According to the supplier documentation, LI-COR is the only supplier\noffering an open-path methane Eddy Covariance system with extensive field validation and long-term scientific use. The system further provides microsecond-level synchronization of instruments through Precision Time Protocol (PTP) and GPS-based clock control, which are essential for accurate flux calculations and data consistency. The system includes EddyPro, a widely adopted Eddy Covariance processing software used by international research\ninfrastructures and flux networks, including ICOS. The software environment, data handling capabilities and compatibility with established network requirements are essential for ensuring data quality, comparability and long-term usability of the measurements generated within the project.\nThe Eddy Covariance tower will be installed as temporary research infrastructure and will be dismantled and relocated to other research sites upon completion of the project. The tower and instrumentation therefore constitute reusable scientific infrastructure. Based on the market assessment, no reasonable alternative supplier was identified that could provide an equivalent integrated solution meeting all technical requirements for open-path methane Eddy Covariance\nmeasurements, synchronization, processing and compatibility with international flux research infrastructures and DTU therefore intends to award the contract to LI-COR Biosciences GmbH.","bkSubTypeKode":"25","bkSubType":"Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed – det generelle direktiv","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]},"opsummeringEN":{"card":{"titel":"Purchase of Eddy Covariance System for continuous measurements of CO₂, H₂O and CH₄ fluxes","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2026-09-23+02:00","cpvKode":"38290000","cpvTitel":"Surveying, hydrographic, oceanographic and hydrological instruments and appliances","formulartype":"Direct award preannouncement","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU requires the acquisition of one complete eddy covariance measurement station for continuous, long-term monitoring of exchanges of carbon dioxide (CO₂), methane (CH₄), water vapour, heat, and momentum between an apple orchard and the atmosphere. The system will be used for research on climate impacts, greenhouse gas balances, carbon sequestration, water use, and sustainable agricultural production.  \n\nThe acquisition comprises a fully integrated field measurement station capable of operating autonomously under outdoor conditions throughout the year and generating high-frequency measurements suitable for eddy covariance flux calculations.  \n\nThe acquisition includes: \n• 1 three-dimensional sonic anemometer for high-frequency measurement of wind speed and wind direction. \n• 1 open-path carbon dioxide and water vapour analyser for continuous measurement of atmospheric CO₂ and H₂O concentrations. \n• 1 open-path methane analyser for continuous measurement of atmospheric CH₄ concentrations. \n• 1 integrated data acquisition, processing, storage, and communication system for synchronization, logging, quality control, and transfer of measurement data. \n• 1 meteorological measurement package comprising sensors for air temperature, relative humidity, precipitation, solar radiation, photosynthetically active radiation (PAR), net radiation, soil moisture, soil temperature, and soil heat flux. \n• 1 backup power and data retention system to ensure continued operation and prevent data loss during temporary interruptions. \n• 1 software package for data processing, quality assurance, visualization, footprint analysis, gap filling, and management of eddy covariance data. \n• 1 galvanized lattice measurement tower with a height of approximately 12 m, including foundation, mounting hardware, transport, and installation. The tower is required to position sensors above the orchard canopy and provide safe access for installation and maintenance. \n• 1 solar power system comprising photovoltaic panels, batteries, charge controller, mounting hardware, cabling, and associated electrical components required for autonomous operation at a field site without permanent grid connection.\n• All cables, communication equipment, sensor mounts, brackets, connectors, and\naccessories required for a complete operational system.\n\nDTU requires a complete Eddy Covariance system for continuous measurement of ecosystematmosphere exchanges of carbon dioxide (CO₂), water vapour (H₂O), methane (CH₄) and energy in an experimental apple orchard. The system must provide high-frequency measurements, robust long-term field operation, standardized data processing and compatibility with established international flux research infrastructures.\n\nA market assessment was performed to identify suppliers capable of delivering a complete Eddy Covariance solution that meets the scientific and technical requirements of the project. Suppliers investigated included LI-COR Biosciences, Campbell Scientific, Picarro and Los Gatos Research. Several suppliers can provide systems for CO₂ and H₂O flux measurements. However, LI-COR is the only supplier identified that can provide the required integrated Eddy Covariance\nplatform including an open-path methane analyser, synchronized measurement architecture, integrated real-time flux processing and established compatibility with major international flux monitoring networks. \n\nThe proposed system includes the LI-7700 open-path methane analyser integrated with the LI-7900 EddyFlux platform. According to the supplier documentation, LI-COR is the only supplier\noffering an open-path methane Eddy Covariance system with extensive field validation and long-term scientific use. The system further provides microsecond-level synchronization of instruments through Precision Time Protocol (PTP) and GPS-based clock control, which are essential for accurate flux calculations and data consistency. The system includes EddyPro, a widely adopted Eddy Covariance processing software used by international research\ninfrastructures and flux networks, including ICOS. The software environment, data handling capabilities and compatibility with established network requirements are essential for ensuring data quality, comparability and long-term usability of the measurements generated within the project.\nThe Eddy Covariance tower will be installed as temporary research infrastructure and will be dismantled and relocated to other research sites upon completion of the project. The tower and instrumentation therefore constitute reusable scientific infrastructure. Based on the market assessment, no reasonable alternative supplier was identified that could provide an equivalent integrated solution meeting all technical requirements for open-path methane Eddy Covariance\nmeasurements, synchronization, processing and compatibility with international flux research infrastructures and DTU therefore intends to award the contract to LI-COR Biosciences GmbH.","bkSubTypeKode":"25","bkSubType":"Voluntary ex-ante transparency notice – general directive","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]}}