{"bekendtgoerelseNoegle":{"noticeId":{"value":"8f04f827-6e32-4c21-ab26-797c84b88bcc"},"noticeVersion":{"value":"01"},"noticePublicationNumber":{"value":"00561640-2025"}},"htmlDA":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Køber</span><section>1.1&nbsp;<span class=\"label\">Køber</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Køberens retlige status</span><span class=\"text\">: </span><span class=\"dynamic-label\">Offentligretligt organ</span></section>\n            <section><span class=\"label\">Den ordregivende myndigheds aktivitet</span><span class=\"text\">: </span><span class=\"dynamic-label\">Uddannelse</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Delivery of Gradient Coil for human magnetic resonance imaging</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and\n                  human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized\n                  carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of\n                  around a second for calculation of metabolic rates. This requires gradient performance\n                  exceeding that of clinical scanners. To drive the gradient coil at the needed slew\n                  rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies\n                  the output at specific frequencies multi-fold. An integrated capacitor bank is needed\n                  to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen\n                  to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073).\n                  To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around\n                  0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of\n                  1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be\n                  near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application\n                  shall include functional MRI with visual stimulation, so the gradient coil needs to\n                  be open in front of the subject eyes. Since the coil will only be relevant for a patient\n                  sub-group, it needs to be mountable and configured within an hour to enable flexible\n                  use of the scanner with intermittent coil use required to enable clinical translation.\n                  The coil needs to be designed, built and equipped with safety measures (sensors) so\n                  it can be approved for human use, even though CE labelling is not a requirement. Market\n                  research has shown, that the only supplier of resonant human-suited head insert gradient\n                  coils is Futura Composites BV that can fulfill the requirements above. Therefore,\n                  DTU intends to issue a purchase order to the company.</span></section>\n            <section><span class=\"label\">Identifikator for proceduren</span><span class=\"text\">: </span><span class=\"value\">34152a87-f7a2-43e2-ae7d-172a1a32a57b</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10253</span></section>\n            <section><span class=\"label\">Udbudsprocedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Udbud med forhandling uden forudgående offentliggørelse</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scannere</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Retsgrundlag</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Direktiv 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Delkontrakt</span><section>5.1&nbsp;<span class=\"label\">Teknisk ID for delkontrakten</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Delivery of Ultrasonic Gradient Coil</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and\n                  human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized\n                  carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of\n                  around a second for calculation of metabolic rates. This requires gradient performance\n                  exceeding that of clinical scanners. To drive the gradient coil at the needed slew\n                  rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies\n                  the output at specific frequencies multi-fold. An integrated capacitor bank is needed\n                  to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen\n                  to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073).\n                  To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around\n                  0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of\n                  1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be\n                  near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application\n                  shall include functional MRI with visual stimulation, so the gradient coil needs to\n                  be open in front of the subject eyes. Since the coil will only be relevant for a patient\n                  sub-group, it needs to be mountable and configured within an hour to enable flexible\n                  use of the scanner with intermittent coil use required to enable clinical translation.\n                  The coil needs to be designed, built and equipped with safety measures (sensors) so\n                  it can be approved for human use, even though CE labelling is not a requirement. Market\n                  research has shown, that the only supplier of resonant human-suited head insert gradient\n                  coils is Futura Composites BV that can fulfill the requirements above. Therefore,\n                  DTU intends to issue a purchase order to the company.</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10253</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scannere</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n               <section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Udbuddet er omfattet af aftalen om offentlige udbud (GPA)</span><span class=\"text\">: </span><span class=\"label\">ja</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Yderligere oplysninger, mægling og gennemgang</span><section><span class=\"label\">Organisation med ansvar for mægling</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation med ansvar for klager</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der leverer supplerende oplysninger om udbudsproceduren</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der sikrer adgang til udbudsdokumenterne offline</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Resultater</span><section><span class=\"label\">Værdien af alle kontrakter tildelt i denne bekendtgørelse</span><span class=\"text\">: </span><span class=\"value\">129.966,94</span><span class=\"text\"> </span><span class=\"label\">Euro</span></section>\n         <section><span class=\"label\">Direkte tildeling</span><span class=\"text\">:</span><section><span class=\"label\">Begrundelse for direkte tildeling</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kontrakten kan kun tildeles af en bestemt økonomisk aktør på grund af manglende konkurrence af tekniske årsager</span></section>\n            <section><span class=\"label\">Anden begrundelse</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and\n                  human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized\n                  carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of\n                  around a second for calculation of metabolic rates. This requires gradient performance\n                  exceeding that of clinical scanners. To drive the gradient coil at the needed slew\n                  rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies\n                  the output at specific frequencies multi-fold. An integrated capacitor bank is needed\n                  to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen\n                  to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073).\n                  To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around\n                  0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of\n                  1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be\n                  near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application\n                  shall include functional MRI with visual stimulation, so the gradient coil needs to\n                  be open in front of the subject eyes. Since the coil will only be relevant for a patient\n                  sub-group, it needs to be mountable and configured within an hour to enable flexible\n                  use of the scanner with intermittent coil use required to enable clinical translation.\n                  The coil needs to be designed, built and equipped with safety measures (sensors) so\n                  it can be approved for human use, even though CE labelling is not a requirement. <br/>Market\n                  research has shown, that the only supplier of resonant human-suited head insert gradient\n                  coils is Futura Composites BV that can fulfill the requirements above. Therefore,\n                  DTU intends to issue a purchase order to the company.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Resultat delkontrakt-ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Oplysninger om vinderne</span><section><span class=\"label\">Vinder</span><span class=\"text\">:</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Futura Composites BV</span></section>\n                  <section><span class=\"label\">Tilbud</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tilbud – Identifikator</span><span class=\"text\">: </span><span class=\"value\">10253 Ultrasonic Gradient Coil</span></section>\n                  <section><span class=\"label\">ID for delkontrakt eller gruppe af delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Kontraktoplysninger</span><span class=\"text\">:</span><section><span class=\"label\">Identifikator for kontrakten</span><span class=\"text\">: </span><span class=\"value\">10253 Ultrasonic Gradient Coil, 10253-Ultrasonic Gradient Coil</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisationer</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">Per Christiansen</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">perach@dtu.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 45252525</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Køberprofil</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Køber</span></section>\n               <section><span class=\"label\">Organisation, der leverer supplerende oplysninger om udbudsproceduren</span></section>\n               <section><span class=\"label\">Organisation, der sikrer adgang til udbudsdokumenterne offline</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for klager</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for mægling</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Futura Composites BV</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">NL809033628B01</span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Heerhugowaard</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">1704 RG</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Noord-Friesland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NL127</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Nederlandene</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">M. Borgo</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">futura@futuracomposites.nl</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+31 725715888</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.futuracomposites.nl</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Tilbudsgiver</span></section>\n               <section><span class=\"label\">Vinder af disse delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norge</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Oplysninger om bekendtgørelsen</span><section><span class=\"label\">Bekendtgørelsens ID</span><span class=\"text\">: </span><span class=\"value\">8f04f827-6e32-4c21-ab26-797c84b88bcc</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Formulartype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Forudgående underretning om direkte tildeling</span></section>\n         <section><span class=\"label\">Bekendtgørelsestype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed</span></section>\n         <section><span class=\"label\">Afsendelsesdato for bekendtgørelsen</span><span class=\"text\">: </span><span class=\"value\">27-08-2025</span><span class=\"text\"> </span><span class=\"value\">07:20 +00:00</span></section>\n         <section><span class=\"label\">Dato for afsendelse af bekendtgørelsen (eSender)</span><span class=\"text\">: </span><span class=\"value\">27-08-2025</span><span class=\"text\"> </span><span class=\"value\">08:00 +00:00</span></section>\n         <section><span class=\"label\">Bekendtgørelsens officielle sprog</span><span class=\"text\">: </span><span class=\"dynamic-label\">engelsk</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Bekendtgørelsesnummer</span><span class=\"text\">: </span><span class=\"value\">00561640-2025</span></section>\n         <section><span class=\"label\">EUT-S-nummer</span><span class=\"text\">: </span><span class=\"value\">164/2025</span></section>\n         <section><span class=\"label\">Offentliggørelsesdato</span><span class=\"text\">: </span><span class=\"value\">28-08-2025</span></section>\n      </section>\n   </body>\n</html>","htmlEN":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Buyer</span><section>1.1&nbsp;<span class=\"label\">Buyer</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Legal type of the buyer</span><span class=\"text\">: </span><span class=\"dynamic-label\">Body governed by public law</span></section>\n            <section><span class=\"label\">Activity of the contracting authority</span><span class=\"text\">: </span><span class=\"dynamic-label\">Education</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Delivery of Gradient Coil for human magnetic resonance imaging</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and\n                  human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized\n                  carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of\n                  around a second for calculation of metabolic rates. This requires gradient performance\n                  exceeding that of clinical scanners. To drive the gradient coil at the needed slew\n                  rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies\n                  the output at specific frequencies multi-fold. An integrated capacitor bank is needed\n                  to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen\n                  to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073).\n                  To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around\n                  0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of\n                  1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be\n                  near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application\n                  shall include functional MRI with visual stimulation, so the gradient coil needs to\n                  be open in front of the subject eyes. Since the coil will only be relevant for a patient\n                  sub-group, it needs to be mountable and configured within an hour to enable flexible\n                  use of the scanner with intermittent coil use required to enable clinical translation.\n                  The coil needs to be designed, built and equipped with safety measures (sensors) so\n                  it can be approved for human use, even though CE labelling is not a requirement. Market\n                  research has shown, that the only supplier of resonant human-suited head insert gradient\n                  coils is Futura Composites BV that can fulfill the requirements above. Therefore,\n                  DTU intends to issue a purchase order to the company.</span></section>\n            <section><span class=\"label\">Procedure identifier</span><span class=\"text\">: </span><span class=\"value\">34152a87-f7a2-43e2-ae7d-172a1a32a57b</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10253</span></section>\n            <section><span class=\"label\">Type of procedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Negotiated without prior call for competition</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scanners</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">Legal basis</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Directive 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Lot</span><section>5.1&nbsp;<span class=\"label\">Lot technical ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Delivery of Ultrasonic Gradient Coil</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and\n                  human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized\n                  carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of\n                  around a second for calculation of metabolic rates. This requires gradient performance\n                  exceeding that of clinical scanners. To drive the gradient coil at the needed slew\n                  rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies\n                  the output at specific frequencies multi-fold. An integrated capacitor bank is needed\n                  to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen\n                  to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073).\n                  To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around\n                  0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of\n                  1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be\n                  near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application\n                  shall include functional MRI with visual stimulation, so the gradient coil needs to\n                  be open in front of the subject eyes. Since the coil will only be relevant for a patient\n                  sub-group, it needs to be mountable and configured within an hour to enable flexible\n                  use of the scanner with intermittent coil use required to enable clinical translation.\n                  The coil needs to be designed, built and equipped with safety measures (sensors) so\n                  it can be approved for human use, even though CE labelling is not a requirement. Market\n                  research has shown, that the only supplier of resonant human-suited head insert gradient\n                  coils is Futura Composites BV that can fulfill the requirements above. Therefore,\n                  DTU intends to issue a purchase order to the company.</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10253</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38520000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Scanners</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n               <section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">The procurement is covered by the Government Procurement Agreement (GPA)</span><span class=\"text\">: </span><span class=\"label\">yes</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Further information, mediation and review</span><section><span class=\"label\">Mediation organisation</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Review organisation</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing additional information about the procurement procedure</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing offline access to the procurement documents</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Results</span><section><span class=\"label\">Value of all contracts awarded in this notice</span><span class=\"text\">: </span><span class=\"value\">129.966,94</span><span class=\"text\"> </span><span class=\"label\">Euro</span></section>\n         <section><span class=\"label\">Direct award</span><span class=\"text\">:</span><section><span class=\"label\">Justification for direct award</span><span class=\"text\">: </span><span class=\"dynamic-label\">The contract can be provided only by a particular economic operator because of an absence of competition for technical reasons</span></section>\n            <section><span class=\"label\">Other justification</span><span class=\"text\">: </span><span class=\"value\">DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and\n                  human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized\n                  carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of\n                  around a second for calculation of metabolic rates. This requires gradient performance\n                  exceeding that of clinical scanners. To drive the gradient coil at the needed slew\n                  rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies\n                  the output at specific frequencies multi-fold. An integrated capacitor bank is needed\n                  to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen\n                  to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073).\n                  To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around\n                  0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of\n                  1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be\n                  near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application\n                  shall include functional MRI with visual stimulation, so the gradient coil needs to\n                  be open in front of the subject eyes. Since the coil will only be relevant for a patient\n                  sub-group, it needs to be mountable and configured within an hour to enable flexible\n                  use of the scanner with intermittent coil use required to enable clinical translation.\n                  The coil needs to be designed, built and equipped with safety measures (sensors) so\n                  it can be approved for human use, even though CE labelling is not a requirement. <br/>Market\n                  research has shown, that the only supplier of resonant human-suited head insert gradient\n                  coils is Futura Composites BV that can fulfill the requirements above. Therefore,\n                  DTU intends to issue a purchase order to the company.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Result lot ldentifier</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Information about winners</span><section><span class=\"label\">Winner</span><span class=\"text\">:</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Futura Composites BV</span></section>\n                  <section><span class=\"label\">Tender</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tender identifier</span><span class=\"text\">: </span><span class=\"value\">10253 Ultrasonic Gradient Coil</span></section>\n                  <section><span class=\"label\">Identifier of lot or group of lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Contract information</span><span class=\"text\">:</span><section><span class=\"label\">Identifier of the contract</span><span class=\"text\">: </span><span class=\"value\">10253 Ultrasonic Gradient Coil, 10253-Ultrasonic Gradient Coil</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisations</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">Per Christiansen</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">perach@dtu.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 45252525</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Buyer profile</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Buyer</span></section>\n               <section><span class=\"label\">Organisation providing additional information about the procurement procedure</span></section>\n               <section><span class=\"label\">Organisation providing offline access to the procurement documents</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Review organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Mediation organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Futura Composites BV</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">NL809033628B01</span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Heerhugowaard</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">1704 RG</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Noord-Friesland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NL127</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Netherlands</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">M. Borgo</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">futura@futuracomposites.nl</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+31 725715888</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.futuracomposites.nl</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Tenderer</span></section>\n               <section><span class=\"label\">Winner of these lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norway</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Notice information</span><section><span class=\"label\">Notice identifier/version</span><span class=\"text\">: </span><span class=\"value\">8f04f827-6e32-4c21-ab26-797c84b88bcc</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Form type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Direct award preannouncement</span></section>\n         <section><span class=\"label\">Notice type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Voluntary ex-ante transparency notice</span></section>\n         <section><span class=\"label\">Notice dispatch date</span><span class=\"text\">: </span><span class=\"value\">27-08-2025</span><span class=\"text\"> </span><span class=\"value\">07:20 +00:00</span></section>\n         <section><span class=\"label\">Notice dispatch date (eSender)</span><span class=\"text\">: </span><span class=\"value\">27-08-2025</span><span class=\"text\"> </span><span class=\"value\">08:00 +00:00</span></section>\n         <section><span class=\"label\">Languages in which this notice is officially available</span><span class=\"text\">: </span><span class=\"dynamic-label\">English</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Notice publication number</span><span class=\"text\">: </span><span class=\"value\">00561640-2025</span></section>\n         <section><span class=\"label\">OJ S issue number</span><span class=\"text\">: </span><span class=\"value\">164/2025</span></section>\n         <section><span class=\"label\">Publication date</span><span class=\"text\">: </span><span class=\"value\">28-08-2025</span></section>\n      </section>\n   </body>\n</html>","opsummeringDA":{"card":{"titel":"Delivery of Gradient Coil for human magnetic resonance imaging","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2025-08-28+02:00","cpvKode":"38520000","cpvTitel":"Scannere","formulartype":"Forudgående underretning om direkte tildeling","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. This requires gradient performance exceeding that of clinical scanners. To drive the gradient coil at the needed slew rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies the output at specific frequencies multi-fold. An integrated capacitor bank is needed to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073). To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around 0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of 1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application shall include functional MRI with visual stimulation, so the gradient coil needs to be open in front of the subject eyes. Since the coil will only be relevant for a patient sub-group, it needs to be mountable and configured within an hour to enable flexible use of the scanner with intermittent coil use required to enable clinical translation. The coil needs to be designed, built and equipped with safety measures (sensors) so it can be approved for human use, even though CE labelling is not a requirement. Market research has shown, that the only supplier of resonant human-suited head insert gradient coils is Futura Composites BV that can fulfill the requirements above. Therefore, DTU intends to issue a purchase order to the company.","bkSubTypeKode":"25","bkSubType":"Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed – det generelle direktiv","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]},"opsummeringEN":{"card":{"titel":"Delivery of Gradient Coil for human magnetic resonance imaging","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2025-08-28+02:00","cpvKode":"38520000","cpvTitel":"Scanners","formulartype":"Direct award preannouncement","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. This requires gradient performance exceeding that of clinical scanners. To drive the gradient coil at the needed slew rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies the output at specific frequencies multi-fold. An integrated capacitor bank is needed to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073). To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around 0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of 1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application shall include functional MRI with visual stimulation, so the gradient coil needs to be open in front of the subject eyes. Since the coil will only be relevant for a patient sub-group, it needs to be mountable and configured within an hour to enable flexible use of the scanner with intermittent coil use required to enable clinical translation. The coil needs to be designed, built and equipped with safety measures (sensors) so it can be approved for human use, even though CE labelling is not a requirement. Market research has shown, that the only supplier of resonant human-suited head insert gradient coils is Futura Composites BV that can fulfill the requirements above. Therefore, DTU intends to issue a purchase order to the company.","bkSubTypeKode":"25","bkSubType":"Voluntary ex-ante transparency notice – general directive","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]}}