{"bekendtgoerelseNoegle":{"noticeId":{"value":"6b3228df-7f8f-4275-9477-7834c3e8b634"},"noticeVersion":{"value":"01"},"noticePublicationNumber":{"value":"00631772-2025"}},"htmlDA":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Køber</span><section>1.1&nbsp;<span class=\"label\">Køber</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Køberens retlige status</span><span class=\"text\">: </span><span class=\"dynamic-label\">Offentligretligt organ</span></section>\n            <section><span class=\"label\">Den ordregivende myndigheds aktivitet</span><span class=\"text\">: </span><span class=\"dynamic-label\">Uddannelse</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Purchase of benchtop NMR spectrometer</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments\n                  GmbH based on the following.<br/><br/>The research in the Magnetic Resonance and Electrochemistry\n                  Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is\n                  required. This spectrometer requires some specific characteristics for the specific\n                  research needs of the group: full broadband tuneability, pulsed-field gradients (PFG),\n                  operando capabilities, and temperature control. It is also important that the probes\n                  are user-accessible so they can be easily serviced and upgraded as necessary with\n                  modular hardware. Further, the experiments should be modifiable such that NMR methods\n                  can be altered and developed according to the group’s specific needs.<br/><br/>Broadband\n                  tuneability: The instrument should be completely broadband tuneable (not limited to\n                  a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include\n                  low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to\n                  be tuned simultaneously. <br/>Pulsed-field gradients: The instrument requires PFG\n                  capability in order to perform the specific transport experiments intended by the\n                  group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial\n                  resolution as well as being able to probe electrolyte transport with PFG-NMR.<br/>Operando\n                  capabilities: The spectrometer probe should be removable by general users without\n                  a need for specialised tools and should be generally accessible to facilitate operando\n                  experimental setups. This spectrometer should be easy to transport for online monitoring\n                  of experiments via a flow system. The system should also be able to integrate peripheral\n                  devices that can be triggered during the experiments. A hardware lock is preferable\n                  to maintain high-quality experiments in operando.<br/>Temperature control: The temperature\n                  of the sample must be adjustable independently and de-coupled from the magnet temperature.\n                  Wide temperature control is needed to probe different conditions of battery operation,\n                  from freezing temperatures to electrolyte breakdown temperatures, enabling the study\n                  of operation at extreme conditions and the effects of storage temperatures. Direct\n                  heating to sample<br/>Experiment development: The system should enable modification\n                  of NMR experiments (pulse sequences) for method development.<br/><br/>This unique\n                  combination of capability is required for the group’s particular research intentions\n                  to study battery electrolytes in situ using combinations of magnetic resonance imaging,\n                  and holistic analytical chemistry. This includes operating electrochemical cells within\n                  the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics\n                  throughout these experiments.<br/><br/>There are very few available benchtop NMR spectrometers\n                  on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally\n                  lack modification capabilities as they are targeted at operators rather than expert\n                  users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets\n                  the specific combination of technical requirements of the group, which are:<br/>1)\n                  Complete broadband tuneability, including to low-gamma nuclides, with no limit on\n                  number<br/>2) Pulsed-field gradient capabilities with gradient strengths &gt;0.5 T/m<br/>3)\n                  Integrated chemically resistant flow setup for online monitoring<br/>4) Easily accessible\n                  and removable probe, enabling simple maintenance and upgradability<br/>5) Hardware\n                  2H locking system for consistent lock without the need for deuterated solvents<br/>6)\n                  Easy-to-move system for relocation to experimental setups<br/>7) Wide temperature\n                  control (0-65 °C) covering temperatures relevant for monitoring battery processes<br/>While\n                  the competitor products may offer a selection of these capabilities, their instruments\n                  do not have the specific combination of technical specifications required for the\n                  intended work. Therefore, the Oxford Instruments X-Pulse system is the only system\n                  that can meet all the necessary requirements for the group’s intended needs.</span></section>\n            <section><span class=\"label\">Identifikator for proceduren</span><span class=\"text\">: </span><span class=\"value\">a91a3903-f49f-454f-b3c5-1e6879508104</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10364</span></section>\n            <section><span class=\"label\">Udbudsprocedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Udbud med forhandling uden forudgående offentliggørelse</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">33113110</span><span class=\"text\"> </span><span class=\"dynamic-label\">NMR-scannere</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Retsgrundlag</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Direktiv 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Delkontrakt</span><section>5.1&nbsp;<span class=\"label\">Teknisk ID for delkontrakten</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Purchase of benchtop NMR spectrometer</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments\n                  GmbH based on the following.<br/><br/>The research in the Magnetic Resonance and Electrochemistry\n                  Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is\n                  required. This spectrometer requires some specific characteristics for the specific\n                  research needs of the group: full broadband tuneability, pulsed-field gradients (PFG),\n                  operando capabilities, and temperature control. It is also important that the probes\n                  are user-accessible so they can be easily serviced and upgraded as necessary with\n                  modular hardware. Further, the experiments should be modifiable such that NMR methods\n                  can be altered and developed according to the group’s specific needs.<br/><br/>Broadband\n                  tuneability: The instrument should be completely broadband tuneable (not limited to\n                  a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include\n                  low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to\n                  be tuned simultaneously. <br/>Pulsed-field gradients: The instrument requires PFG\n                  capability in order to perform the specific transport experiments intended by the\n                  group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial\n                  resolution as well as being able to probe electrolyte transport with PFG-NMR.<br/>Operando\n                  capabilities: The spectrometer probe should be removable by general users without\n                  a need for specialised tools and should be generally accessible to facilitate operando\n                  experimental setups. This spectrometer should be easy to transport for online monitoring\n                  of experiments via a flow system. The system should also be able to integrate peripheral\n                  devices that can be triggered during the experiments. A hardware lock is preferable\n                  to maintain high-quality experiments in operando.<br/>Temperature control: The temperature\n                  of the sample must be adjustable independently and de-coupled from the magnet temperature.\n                  Wide temperature control is needed to probe different conditions of battery operation,\n                  from freezing temperatures to electrolyte breakdown temperatures, enabling the study\n                  of operation at extreme conditions and the effects of storage temperatures. Direct\n                  heating to sample<br/>Experiment development: The system should enable modification\n                  of NMR experiments (pulse sequences) for method development.<br/><br/>This unique\n                  combination of capability is required for the group’s particular research intentions\n                  to study battery electrolytes in situ using combinations of magnetic resonance imaging,\n                  and holistic analytical chemistry. This includes operating electrochemical cells within\n                  the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics\n                  throughout these experiments.<br/><br/>There are very few available benchtop NMR spectrometers\n                  on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally\n                  lack modification capabilities as they are targeted at operators rather than expert\n                  users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets\n                  the specific combination of technical requirements of the group, which are:<br/>1)\n                  Complete broadband tuneability, including to low-gamma nuclides, with no limit on\n                  number<br/>2) Pulsed-field gradient capabilities with gradient strengths &gt;0.5 T/m<br/>3)\n                  Integrated chemically resistant flow setup for online monitoring<br/>4) Easily accessible\n                  and removable probe, enabling simple maintenance and upgradability<br/>5) Hardware\n                  2H locking system for consistent lock without the need for deuterated solvents<br/>6)\n                  Easy-to-move system for relocation to experimental setups<br/>7) Wide temperature\n                  control (0-65 °C) covering temperatures relevant for monitoring battery processes<br/>While\n                  the competitor products may offer a selection of these capabilities, their instruments\n                  do not have the specific combination of technical specifications required for the\n                  intended work. Therefore, the Oxford Instruments X-Pulse system is the only system\n                  that can meet all the necessary requirements for the group’s intended needs.</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">10364</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">33113110</span><span class=\"text\"> </span><span class=\"dynamic-label\">NMR-scannere</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"dynamic-label\">Hvor som helst</span></section>\n               <section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Udbuddet er omfattet af aftalen om offentlige udbud (GPA)</span><span class=\"text\">: </span><span class=\"label\">ja</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Yderligere oplysninger, mægling og gennemgang</span><section><span class=\"label\">Organisation med ansvar for mægling</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation med ansvar for klager</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Resultater</span><section><span class=\"label\">Værdien af alle kontrakter tildelt i denne bekendtgørelse</span><span class=\"text\">: </span><span class=\"value\">136.800</span><span class=\"text\"> </span><span class=\"label\">Euro</span></section>\n         <section><span class=\"label\">Direkte tildeling</span><span class=\"text\">:</span><section><span class=\"label\">Begrundelse for direkte tildeling</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kontrakten kan kun tildeles af en bestemt økonomisk aktør på grund af manglende konkurrence af tekniske årsager</span></section>\n            <section><span class=\"label\">Anden begrundelse</span><span class=\"text\">: </span><span class=\"value\">DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments\n                  GmbH based on the following.<br/><br/>The research in the Magnetic Resonance and Electrochemistry\n                  Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is\n                  required. This spectrometer requires some specific characteristics for the specific\n                  research needs of the group: full broadband tuneability, pulsed-field gradients (PFG),\n                  operando capabilities, and temperature control. It is also important that the probes\n                  are user-accessible so they can be easily serviced and upgraded as necessary with\n                  modular hardware. Further, the experiments should be modifiable such that NMR methods\n                  can be altered and developed according to the group’s specific needs.<br/><br/>Broadband\n                  tuneability: The instrument should be completely broadband tuneable (not limited to\n                  a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include\n                  low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to\n                  be tuned simultaneously. <br/>Pulsed-field gradients: The instrument requires PFG\n                  capability in order to perform the specific transport experiments intended by the\n                  group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial\n                  resolution as well as being able to probe electrolyte transport with PFG-NMR.<br/>Operando\n                  capabilities: The spectrometer probe should be removable by general users without\n                  a need for specialised tools and should be generally accessible to facilitate operando\n                  experimental setups. This spectrometer should be easy to transport for online monitoring\n                  of experiments via a flow system. The system should also be able to integrate peripheral\n                  devices that can be triggered during the experiments. A hardware lock is preferable\n                  to maintain high-quality experiments in operando.<br/>Temperature control: The temperature\n                  of the sample must be adjustable independently and de-coupled from the magnet temperature.\n                  Wide temperature control is needed to probe different conditions of battery operation,\n                  from freezing temperatures to electrolyte breakdown temperatures, enabling the study\n                  of operation at extreme conditions and the effects of storage temperatures. Direct\n                  heating to sample<br/>Experiment development: The system should enable modification\n                  of NMR experiments (pulse sequences) for method development.<br/><br/>This unique\n                  combination of capability is required for the group’s particular research intentions\n                  to study battery electrolytes in situ using combinations of magnetic resonance imaging,\n                  and holistic analytical chemistry. This includes operating electrochemical cells within\n                  the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics\n                  throughout these experiments.<br/><br/>There are very few available benchtop NMR spectrometers\n                  on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally\n                  lack modification capabilities as they are targeted at operators rather than expert\n                  users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets\n                  the specific combination of technical requirements of the group, which are:<br/>1)\n                  Complete broadband tuneability, including to low-gamma nuclides, with no limit on\n                  number<br/>2) Pulsed-field gradient capabilities with gradient strengths &gt;0.5 T/m<br/>3)\n                  Integrated chemically resistant flow setup for online monitoring<br/>4) Easily accessible\n                  and removable probe, enabling simple maintenance and upgradability<br/>5) Hardware\n                  2H locking system for consistent lock without the need for deuterated solvents<br/>6)\n                  Easy-to-move system for relocation to experimental setups<br/>7) Wide temperature\n                  control (0-65 °C) covering temperatures relevant for monitoring battery processes<br/>While\n                  the competitor products may offer a selection of these capabilities, their instruments\n                  do not have the specific combination of technical specifications required for the\n                  intended work. Therefore, the Oxford Instruments X-Pulse system is the only system\n                  that can meet all the necessary requirements for the group’s intended needs.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Resultat delkontrakt-ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Oplysninger om vinderne</span><section><span class=\"label\">Vinder</span><span class=\"text\">:</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Oxford Instruments GmbH</span></section>\n                  <section><span class=\"label\">Tilbud</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tilbud – Identifikator</span><span class=\"text\">: </span><span class=\"value\">10364 - Purchase of benchtop NMR spectrometer</span></section>\n                  <section><span class=\"label\">ID for delkontrakt eller gruppe af delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Kontraktoplysninger</span><span class=\"text\">:</span><section><span class=\"label\">Identifikator for kontrakten</span><span class=\"text\">: </span><span class=\"value\">10364 - Purchase of benchtop NMR spectrometer</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisationer</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">Lise Nørhaven</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">lisno@dtu.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 93510927</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Køberprofil</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Køber</span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for klager</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for mægling</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Oxford Instruments GmbH</span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Wiesbaden</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">65205</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Wiesbaden, Kreisfreie Stadt</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DE714</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tyskland</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Tilbudsgiver</span></section>\n               <section><span class=\"label\">Vinder af disse delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norge</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Oplysninger om bekendtgørelsen</span><section><span class=\"label\">Bekendtgørelsens ID</span><span class=\"text\">: </span><span class=\"value\">6b3228df-7f8f-4275-9477-7834c3e8b634</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Formulartype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Forudgående underretning om direkte tildeling</span></section>\n         <section><span class=\"label\">Bekendtgørelsestype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed</span></section>\n         <section><span class=\"label\">Afsendelsesdato for bekendtgørelsen</span><span class=\"text\">: </span><span class=\"value\">24-09-2025</span><span class=\"text\"> </span><span class=\"value\">12:36 +00:00</span></section>\n         <section><span class=\"label\">Dato for afsendelse af bekendtgørelsen (eSender)</span><span class=\"text\">: </span><span class=\"value\">24-09-2025</span><span class=\"text\"> </span><span class=\"value\">13:00 +00:00</span></section>\n         <section><span class=\"label\">Bekendtgørelsens officielle sprog</span><span class=\"text\">: </span><span class=\"dynamic-label\">engelsk</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Bekendtgørelsesnummer</span><span class=\"text\">: </span><span class=\"value\">00631772-2025</span></section>\n         <section><span class=\"label\">EUT-S-nummer</span><span class=\"text\">: </span><span class=\"value\">185/2025</span></section>\n         <section><span class=\"label\">Offentliggørelsesdato</span><span class=\"text\">: </span><span class=\"value\">26-09-2025</span></section>\n      </section>\n   </body>\n</html>","htmlEN":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Buyer</span><section>1.1&nbsp;<span class=\"label\">Buyer</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Legal type of the buyer</span><span class=\"text\">: </span><span class=\"dynamic-label\">Body governed by public law</span></section>\n            <section><span class=\"label\">Activity of the contracting authority</span><span class=\"text\">: </span><span class=\"dynamic-label\">Education</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Purchase of benchtop NMR spectrometer</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments\n                  GmbH based on the following.<br/><br/>The research in the Magnetic Resonance and Electrochemistry\n                  Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is\n                  required. This spectrometer requires some specific characteristics for the specific\n                  research needs of the group: full broadband tuneability, pulsed-field gradients (PFG),\n                  operando capabilities, and temperature control. It is also important that the probes\n                  are user-accessible so they can be easily serviced and upgraded as necessary with\n                  modular hardware. Further, the experiments should be modifiable such that NMR methods\n                  can be altered and developed according to the group’s specific needs.<br/><br/>Broadband\n                  tuneability: The instrument should be completely broadband tuneable (not limited to\n                  a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include\n                  low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to\n                  be tuned simultaneously. <br/>Pulsed-field gradients: The instrument requires PFG\n                  capability in order to perform the specific transport experiments intended by the\n                  group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial\n                  resolution as well as being able to probe electrolyte transport with PFG-NMR.<br/>Operando\n                  capabilities: The spectrometer probe should be removable by general users without\n                  a need for specialised tools and should be generally accessible to facilitate operando\n                  experimental setups. This spectrometer should be easy to transport for online monitoring\n                  of experiments via a flow system. The system should also be able to integrate peripheral\n                  devices that can be triggered during the experiments. A hardware lock is preferable\n                  to maintain high-quality experiments in operando.<br/>Temperature control: The temperature\n                  of the sample must be adjustable independently and de-coupled from the magnet temperature.\n                  Wide temperature control is needed to probe different conditions of battery operation,\n                  from freezing temperatures to electrolyte breakdown temperatures, enabling the study\n                  of operation at extreme conditions and the effects of storage temperatures. Direct\n                  heating to sample<br/>Experiment development: The system should enable modification\n                  of NMR experiments (pulse sequences) for method development.<br/><br/>This unique\n                  combination of capability is required for the group’s particular research intentions\n                  to study battery electrolytes in situ using combinations of magnetic resonance imaging,\n                  and holistic analytical chemistry. This includes operating electrochemical cells within\n                  the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics\n                  throughout these experiments.<br/><br/>There are very few available benchtop NMR spectrometers\n                  on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally\n                  lack modification capabilities as they are targeted at operators rather than expert\n                  users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets\n                  the specific combination of technical requirements of the group, which are:<br/>1)\n                  Complete broadband tuneability, including to low-gamma nuclides, with no limit on\n                  number<br/>2) Pulsed-field gradient capabilities with gradient strengths &gt;0.5 T/m<br/>3)\n                  Integrated chemically resistant flow setup for online monitoring<br/>4) Easily accessible\n                  and removable probe, enabling simple maintenance and upgradability<br/>5) Hardware\n                  2H locking system for consistent lock without the need for deuterated solvents<br/>6)\n                  Easy-to-move system for relocation to experimental setups<br/>7) Wide temperature\n                  control (0-65 °C) covering temperatures relevant for monitoring battery processes<br/>While\n                  the competitor products may offer a selection of these capabilities, their instruments\n                  do not have the specific combination of technical specifications required for the\n                  intended work. Therefore, the Oxford Instruments X-Pulse system is the only system\n                  that can meet all the necessary requirements for the group’s intended needs.</span></section>\n            <section><span class=\"label\">Procedure identifier</span><span class=\"text\">: </span><span class=\"value\">a91a3903-f49f-454f-b3c5-1e6879508104</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10364</span></section>\n            <section><span class=\"label\">Type of procedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Negotiated without prior call for competition</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">33113110</span><span class=\"text\"> </span><span class=\"dynamic-label\">Nuclear magnetic resonance scanners</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">Legal basis</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Directive 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Lot</span><section>5.1&nbsp;<span class=\"label\">Lot technical ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Purchase of benchtop NMR spectrometer</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments\n                  GmbH based on the following.<br/><br/>The research in the Magnetic Resonance and Electrochemistry\n                  Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is\n                  required. This spectrometer requires some specific characteristics for the specific\n                  research needs of the group: full broadband tuneability, pulsed-field gradients (PFG),\n                  operando capabilities, and temperature control. It is also important that the probes\n                  are user-accessible so they can be easily serviced and upgraded as necessary with\n                  modular hardware. Further, the experiments should be modifiable such that NMR methods\n                  can be altered and developed according to the group’s specific needs.<br/><br/>Broadband\n                  tuneability: The instrument should be completely broadband tuneable (not limited to\n                  a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include\n                  low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to\n                  be tuned simultaneously. <br/>Pulsed-field gradients: The instrument requires PFG\n                  capability in order to perform the specific transport experiments intended by the\n                  group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial\n                  resolution as well as being able to probe electrolyte transport with PFG-NMR.<br/>Operando\n                  capabilities: The spectrometer probe should be removable by general users without\n                  a need for specialised tools and should be generally accessible to facilitate operando\n                  experimental setups. This spectrometer should be easy to transport for online monitoring\n                  of experiments via a flow system. The system should also be able to integrate peripheral\n                  devices that can be triggered during the experiments. A hardware lock is preferable\n                  to maintain high-quality experiments in operando.<br/>Temperature control: The temperature\n                  of the sample must be adjustable independently and de-coupled from the magnet temperature.\n                  Wide temperature control is needed to probe different conditions of battery operation,\n                  from freezing temperatures to electrolyte breakdown temperatures, enabling the study\n                  of operation at extreme conditions and the effects of storage temperatures. Direct\n                  heating to sample<br/>Experiment development: The system should enable modification\n                  of NMR experiments (pulse sequences) for method development.<br/><br/>This unique\n                  combination of capability is required for the group’s particular research intentions\n                  to study battery electrolytes in situ using combinations of magnetic resonance imaging,\n                  and holistic analytical chemistry. This includes operating electrochemical cells within\n                  the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics\n                  throughout these experiments.<br/><br/>There are very few available benchtop NMR spectrometers\n                  on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally\n                  lack modification capabilities as they are targeted at operators rather than expert\n                  users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets\n                  the specific combination of technical requirements of the group, which are:<br/>1)\n                  Complete broadband tuneability, including to low-gamma nuclides, with no limit on\n                  number<br/>2) Pulsed-field gradient capabilities with gradient strengths &gt;0.5 T/m<br/>3)\n                  Integrated chemically resistant flow setup for online monitoring<br/>4) Easily accessible\n                  and removable probe, enabling simple maintenance and upgradability<br/>5) Hardware\n                  2H locking system for consistent lock without the need for deuterated solvents<br/>6)\n                  Easy-to-move system for relocation to experimental setups<br/>7) Wide temperature\n                  control (0-65 °C) covering temperatures relevant for monitoring battery processes<br/>While\n                  the competitor products may offer a selection of these capabilities, their instruments\n                  do not have the specific combination of technical specifications required for the\n                  intended work. Therefore, the Oxford Instruments X-Pulse system is the only system\n                  that can meet all the necessary requirements for the group’s intended needs.</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">10364</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">33113110</span><span class=\"text\"> </span><span class=\"dynamic-label\">Nuclear magnetic resonance scanners</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"dynamic-label\">Anywhere</span></section>\n               <section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">The procurement is covered by the Government Procurement Agreement (GPA)</span><span class=\"text\">: </span><span class=\"label\">yes</span></section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Further information, mediation and review</span><section><span class=\"label\">Mediation organisation</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Review organisation</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Results</span><section><span class=\"label\">Value of all contracts awarded in this notice</span><span class=\"text\">: </span><span class=\"value\">136.800</span><span class=\"text\"> </span><span class=\"label\">Euro</span></section>\n         <section><span class=\"label\">Direct award</span><span class=\"text\">:</span><section><span class=\"label\">Justification for direct award</span><span class=\"text\">: </span><span class=\"dynamic-label\">The contract can be provided only by a particular economic operator because of an absence of competition for technical reasons</span></section>\n            <section><span class=\"label\">Other justification</span><span class=\"text\">: </span><span class=\"value\">DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments\n                  GmbH based on the following.<br/><br/>The research in the Magnetic Resonance and Electrochemistry\n                  Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is\n                  required. This spectrometer requires some specific characteristics for the specific\n                  research needs of the group: full broadband tuneability, pulsed-field gradients (PFG),\n                  operando capabilities, and temperature control. It is also important that the probes\n                  are user-accessible so they can be easily serviced and upgraded as necessary with\n                  modular hardware. Further, the experiments should be modifiable such that NMR methods\n                  can be altered and developed according to the group’s specific needs.<br/><br/>Broadband\n                  tuneability: The instrument should be completely broadband tuneable (not limited to\n                  a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include\n                  low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to\n                  be tuned simultaneously. <br/>Pulsed-field gradients: The instrument requires PFG\n                  capability in order to perform the specific transport experiments intended by the\n                  group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial\n                  resolution as well as being able to probe electrolyte transport with PFG-NMR.<br/>Operando\n                  capabilities: The spectrometer probe should be removable by general users without\n                  a need for specialised tools and should be generally accessible to facilitate operando\n                  experimental setups. This spectrometer should be easy to transport for online monitoring\n                  of experiments via a flow system. The system should also be able to integrate peripheral\n                  devices that can be triggered during the experiments. A hardware lock is preferable\n                  to maintain high-quality experiments in operando.<br/>Temperature control: The temperature\n                  of the sample must be adjustable independently and de-coupled from the magnet temperature.\n                  Wide temperature control is needed to probe different conditions of battery operation,\n                  from freezing temperatures to electrolyte breakdown temperatures, enabling the study\n                  of operation at extreme conditions and the effects of storage temperatures. Direct\n                  heating to sample<br/>Experiment development: The system should enable modification\n                  of NMR experiments (pulse sequences) for method development.<br/><br/>This unique\n                  combination of capability is required for the group’s particular research intentions\n                  to study battery electrolytes in situ using combinations of magnetic resonance imaging,\n                  and holistic analytical chemistry. This includes operating electrochemical cells within\n                  the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics\n                  throughout these experiments.<br/><br/>There are very few available benchtop NMR spectrometers\n                  on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally\n                  lack modification capabilities as they are targeted at operators rather than expert\n                  users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets\n                  the specific combination of technical requirements of the group, which are:<br/>1)\n                  Complete broadband tuneability, including to low-gamma nuclides, with no limit on\n                  number<br/>2) Pulsed-field gradient capabilities with gradient strengths &gt;0.5 T/m<br/>3)\n                  Integrated chemically resistant flow setup for online monitoring<br/>4) Easily accessible\n                  and removable probe, enabling simple maintenance and upgradability<br/>5) Hardware\n                  2H locking system for consistent lock without the need for deuterated solvents<br/>6)\n                  Easy-to-move system for relocation to experimental setups<br/>7) Wide temperature\n                  control (0-65 °C) covering temperatures relevant for monitoring battery processes<br/>While\n                  the competitor products may offer a selection of these capabilities, their instruments\n                  do not have the specific combination of technical specifications required for the\n                  intended work. Therefore, the Oxford Instruments X-Pulse system is the only system\n                  that can meet all the necessary requirements for the group’s intended needs.</span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Result lot ldentifier</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section>6.1.2&nbsp;<span class=\"label\">Information about winners</span><section><span class=\"label\">Winner</span><span class=\"text\">:</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Oxford Instruments GmbH</span></section>\n                  <section><span class=\"label\">Tender</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tender identifier</span><span class=\"text\">: </span><span class=\"value\">10364 - Purchase of benchtop NMR spectrometer</span></section>\n                  <section><span class=\"label\">Identifier of lot or group of lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Contract information</span><span class=\"text\">:</span><section><span class=\"label\">Identifier of the contract</span><span class=\"text\">: </span><span class=\"value\">10364 - Purchase of benchtop NMR spectrometer</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisations</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Danmarks Tekniske Universitet - DTU</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">30060946</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Anker Engelunds Vej 1</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Kgs. Lyngby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">Lise Nørhaven</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">lisno@dtu.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 93510927</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.dtu.dk</span></section>\n            <section><span class=\"label\">Buyer profile</span><span class=\"text\">: </span><span class=\"value\">https://eu.eu-supply.com/ctm/company/companyinformation/index/165863</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Buyer</span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Nævnenes hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Østjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK042</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">klfu@erst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 35291000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Review organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0003</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Byen København</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK011</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 41715000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.kfst.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Mediation organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0004</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Oxford Instruments GmbH</span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Wiesbaden</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">65205</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Wiesbaden, Kreisfreie Stadt</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DE714</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Germany</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Tenderer</span></section>\n               <section><span class=\"label\">Winner of these lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0005</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Mercell Holding ASA</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">980921565</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Askekroken 11</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Oslo</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">0277</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Oslo</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">NO081</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Norway</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">eSender</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">publication@mercell.com</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+47 21018800</span></section>\n            <section><span class=\"label\">Fax</span><span class=\"text\">: </span><span class=\"value\">+47 21018801</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://mercell.com/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Notice information</span><section><span class=\"label\">Notice identifier/version</span><span class=\"text\">: </span><span class=\"value\">6b3228df-7f8f-4275-9477-7834c3e8b634</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Form type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Direct award preannouncement</span></section>\n         <section><span class=\"label\">Notice type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Voluntary ex-ante transparency notice</span></section>\n         <section><span class=\"label\">Notice dispatch date</span><span class=\"text\">: </span><span class=\"value\">24-09-2025</span><span class=\"text\"> </span><span class=\"value\">12:36 +00:00</span></section>\n         <section><span class=\"label\">Notice dispatch date (eSender)</span><span class=\"text\">: </span><span class=\"value\">24-09-2025</span><span class=\"text\"> </span><span class=\"value\">13:00 +00:00</span></section>\n         <section><span class=\"label\">Languages in which this notice is officially available</span><span class=\"text\">: </span><span class=\"dynamic-label\">English</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Notice publication number</span><span class=\"text\">: </span><span class=\"value\">00631772-2025</span></section>\n         <section><span class=\"label\">OJ S issue number</span><span class=\"text\">: </span><span class=\"value\">185/2025</span></section>\n         <section><span class=\"label\">Publication date</span><span class=\"text\">: </span><span class=\"value\">26-09-2025</span></section>\n      </section>\n   </body>\n</html>","opsummeringDA":{"card":{"titel":"Purchase of benchtop NMR spectrometer","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2025-09-26+02:00","cpvKode":"33113110","cpvTitel":"NMR-scannere","formulartype":"Forudgående underretning om direkte tildeling","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments GmbH based on the following.\n\nThe research in the Magnetic Resonance and Electrochemistry Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is required. This spectrometer requires some specific characteristics for the specific research needs of the group: full broadband tuneability, pulsed-field gradients (PFG), operando capabilities, and temperature control. It is also important that the probes are user-accessible so they can be easily serviced and upgraded as necessary with modular hardware. Further, the experiments should be modifiable such that NMR methods can be altered and developed according to the group’s specific needs.\n\nBroadband tuneability: The instrument should be completely broadband tuneable (not limited to a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to be tuned simultaneously. \nPulsed-field gradients: The instrument requires PFG capability in order to perform the specific transport experiments intended by the group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial resolution as well as being able to probe electrolyte transport with PFG-NMR.\nOperando capabilities: The spectrometer probe should be removable by general users without a need for specialised tools and should be generally accessible to facilitate operando experimental setups. This spectrometer should be easy to transport for online monitoring of experiments via a flow system. The system should also be able to integrate peripheral devices that can be triggered during the experiments. A hardware lock is preferable to maintain high-quality experiments in operando.\nTemperature control: The temperature of the sample must be adjustable independently and de-coupled from the magnet temperature. Wide temperature control is needed to probe different conditions of battery operation, from freezing temperatures to electrolyte breakdown temperatures, enabling the study of operation at extreme conditions and the effects of storage temperatures. Direct heating to sample\nExperiment development: The system should enable modification of NMR experiments (pulse sequences) for method development.\n\nThis unique combination of capability is required for the group’s particular research intentions to study battery electrolytes in situ using combinations of magnetic resonance imaging, and holistic analytical chemistry. This includes operating electrochemical cells within the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics throughout these experiments.\n\nThere are very few available benchtop NMR spectrometers on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally lack modification capabilities as they are targeted at operators rather than expert users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets the specific combination of technical requirements of the group, which are:\n1) Complete broadband tuneability, including to low-gamma nuclides, with no limit on number\n2) Pulsed-field gradient capabilities with gradient strengths >0.5 T/m\n3) Integrated chemically resistant flow setup for online monitoring\n4) Easily accessible and removable probe, enabling simple maintenance and upgradability\n5) Hardware 2H locking system for consistent lock without the need for deuterated solvents\n6) Easy-to-move system for relocation to experimental setups\n7) Wide temperature control (0-65 °C) covering temperatures relevant for monitoring battery processes\nWhile the competitor products may offer a selection of these capabilities, their instruments do not have the specific combination of technical specifications required for the intended work. Therefore, the Oxford Instruments X-Pulse system is the only system that can meet all the necessary requirements for the group’s intended needs.","bkSubTypeKode":"25","bkSubType":"Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed – det generelle direktiv","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]},"opsummeringEN":{"card":{"titel":"Purchase of benchtop NMR spectrometer","ordregiver":"Danmarks Tekniske Universitet - DTU","ordregiverId":"30060946","ordregiverIdDatavasket":"30060946","publiceringsdato":"2025-09-26+02:00","cpvKode":"33113110","cpvTitel":"Nuclear magnetic resonance scanners","formulartype":"Direct award preannouncement","formulartypeKode":"dir-awa-pre","tidsfrister":[],"alleOrdregivere":["Danmarks Tekniske Universitet - DTU"],"beskrivelse":"DTU intends to purchase an X-Pulse Benchtop NMR Spectrometer from Oxford Instruments GmbH based on the following.\n\nThe research in the Magnetic Resonance and Electrochemistry Lab at DTU Chemistry, a benchtop nuclear magnetic resonance (NMR) spectrometer is required. This spectrometer requires some specific characteristics for the specific research needs of the group: full broadband tuneability, pulsed-field gradients (PFG), operando capabilities, and temperature control. It is also important that the probes are user-accessible so they can be easily serviced and upgraded as necessary with modular hardware. Further, the experiments should be modifiable such that NMR methods can be altered and developed according to the group’s specific needs.\n\nBroadband tuneability: The instrument should be completely broadband tuneable (not limited to a fixed number), specifically to 1H, 13C, 31P, 19F, and 23Na and should also include low-gamma nu-clides such as 35Cl, 17O, and 6Li; multiple nuclides should be able to be tuned simultaneously. \nPulsed-field gradients: The instrument requires PFG capability in order to perform the specific transport experiments intended by the group. Gradients of at least 0.5 T/m are necessary to achieve appropriate spatial resolution as well as being able to probe electrolyte transport with PFG-NMR.\nOperando capabilities: The spectrometer probe should be removable by general users without a need for specialised tools and should be generally accessible to facilitate operando experimental setups. This spectrometer should be easy to transport for online monitoring of experiments via a flow system. The system should also be able to integrate peripheral devices that can be triggered during the experiments. A hardware lock is preferable to maintain high-quality experiments in operando.\nTemperature control: The temperature of the sample must be adjustable independently and de-coupled from the magnet temperature. Wide temperature control is needed to probe different conditions of battery operation, from freezing temperatures to electrolyte breakdown temperatures, enabling the study of operation at extreme conditions and the effects of storage temperatures. Direct heating to sample\nExperiment development: The system should enable modification of NMR experiments (pulse sequences) for method development.\n\nThis unique combination of capability is required for the group’s particular research intentions to study battery electrolytes in situ using combinations of magnetic resonance imaging, and holistic analytical chemistry. This includes operating electrochemical cells within the magnet, and monitoring electrolyte salts and solvents, as well as diffusion characteristics throughout these experiments.\n\nThere are very few available benchtop NMR spectrometers on the market. The main vendors are Bruker, Oxford, and Magritek. Other vendors generally lack modification capabilities as they are targeted at operators rather than expert users. Of the named vendors, only the X-Pulse system from Oxford Instruments meets the specific combination of technical requirements of the group, which are:\n1) Complete broadband tuneability, including to low-gamma nuclides, with no limit on number\n2) Pulsed-field gradient capabilities with gradient strengths >0.5 T/m\n3) Integrated chemically resistant flow setup for online monitoring\n4) Easily accessible and removable probe, enabling simple maintenance and upgradability\n5) Hardware 2H locking system for consistent lock without the need for deuterated solvents\n6) Easy-to-move system for relocation to experimental setups\n7) Wide temperature control (0-65 °C) covering temperatures relevant for monitoring battery processes\nWhile the competitor products may offer a selection of these capabilities, their instruments do not have the specific combination of technical specifications required for the intended work. Therefore, the Oxford Instruments X-Pulse system is the only system that can meet all the necessary requirements for the group’s intended needs.","bkSubTypeKode":"25","bkSubType":"Voluntary ex-ante transparency notice – general directive","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":[],"udforelsesstedSubLand":[],"udforelsesstedLand":[],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]}}