{"bekendtgoerelseNoegle":{"noticeId":{"value":"048492d6-e305-46b0-879a-c9be10911af9"},"noticeVersion":{"value":"01"},"noticePublicationNumber":{"value":"00616391-2026"}},"htmlDA":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Køber</span><section>1.1&nbsp;<span class=\"label\">Køber</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Syddansk Universitet</span></section>\n            <section><span class=\"label\">Køberens retlige status</span><span class=\"text\">: </span><span class=\"dynamic-label\">Offentligretligt organ</span></section>\n            <section><span class=\"label\">Den ordregivende myndigheds aktivitet</span><span class=\"text\">: </span><span class=\"dynamic-label\">Uddannelse</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Low vibration, high vacuum cryostat, with vector magnet for SDU</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                  vacuum, vibration, electrical, and future upgrade requirements that are essential\n                  for our research. Following a market assessment, only the proposed supplier was identified\n                  as capable of providing a fully integrated system meeting all mandatory specifications.<br/><br/>1.\n                  Product Specifications Required<br/><br/>The system must provide:<br/><br/>•At least\n                  four lateral optical accesses and one top optical access.<br/><br/>•A large cryogenic\n                  sample volume of Ø250 mm cold plate × 250 mm height.<br/><br/>•Non-magnetic radiation\n                  shield with four horizontal and one vertical optical window.<br/><br/>•Three integrated\n                  50 A high-current channels to the 4 K stage.<br/><br/>•Four thermally anchored coaxial\n                  lines for measurements up to 20 GHz.<br/><br/>•Four fibre-optic feedthroughs.<br/><br/>•48\n                  DC electrical connections at the 4 K cold plate.<br/><br/>•Base temperature ≤ 3.5\n                  K with stability better than 50 mK.<br/><br/>•Cooling power of at least 250 mW at\n                  4.2 K.<br/><br/>•Vibration levels below 30 nm peak-to-peak.<br/><br/>•Ultra-high vacuum\n                  better than 1 × 10⁻⁹ mbar.<br/><br/>•Remote cryocooler architecture with unrestricted\n                  360° optical access.<br/><br/>•Future compatibility with a removable 4-1-1 vector\n                  magnet.<br/><br/>•Complete mobility of the cryostat on the optical table.<br/><br/>2.\n                  Why These Specifications Are Necessary<br/><br/>•Large 250 mm sample space: Required\n                  to accommodate complex optical setups, cryogenic positioners, electrical and fibre\n                  connections, and future magnet integration without redesigning the experimental platform.<br/><br/>•Ultra-high\n                  vacuum (UHV): Our experiments run continuously for several weeks. A vacuum level better\n                  than 1 × 10⁻⁹ mbar is essential to avoid contamination of samples and optical windows,\n                  ensuring stable measurement conditions and reproducible results over long measurement\n                  periods.<br/><br/>•Remote cryocooler and ultra-low vibration: Our experiments rely\n                  on interferometric and other vibration-sensitive optical measurements. The cryocooler\n                  must be physically separated from the optical table to minimise vibration and acoustic\n                  noise transmission, while maintaining the flexibility to move the cryostat when experimental\n                  configurations evolve.<br/><br/>•Extensive optical access: Four side windows and one\n                  top window are required to provide simultaneous laser excitation, imaging, collection\n                  optics, and future experimental configurations that cannot be accommodated by standard\n                  cryostat designs.<br/><br/>•Future magnet integration: The system must support straightforward\n                  integration of a 4-1-1 vector magnet and allow different magnet configurations to\n                  be installed or removed without major modifications to the cryostat.<br/><br/>3. Why\n                  There Is Only One Supplier<br/><br/>The selected supplier is the only identified manufacturer\n                  capable of providing all required features within one validated and integrated platform.<br/><br/>In\n                  particular, the supplier uniquely combines:<br/><br/>•A Ø250 mm × 250 mm cryogenic\n                  sample space.<br/><br/>•UHV performance (&lt;10⁻⁹ mbar) suitable for multi-week experiments.<br/><br/>•A\n                  remote cryocooler architecture delivering very low vibration while preserving cryostat\n                  mobility.<br/><br/>•Unobstructed 360° optical access with multiple optical ports.<br/><br/>•Integrated\n                  high-current, RF, fibre-optic, and DC measurement infrastructure.<br/><br/>•A design\n                  specifically prepared for future vector magnet integration and compatibility with\n                  different magnet configurations.<br/><br/>•Cryogenic positioners and cryostat supplied\n                  by the same manufacturer, ensuring full mechanical, thermal, electrical, and software\n                  compatibility while eliminating integration risks.<br/><br/>Although alternative suppliers\n                  may offer some individual features, no other supplier was found that can simultaneously\n                  provide the required UHV performance, large sample volume, remote low-vibration architecture,\n                  extensive optical access, future magnet flexibility, and fully integrated cryogenic\n                  positioning system. We have nonetheless ensured that the terms of acquisition reflect\n                  sound financial judgment and serve the best interests of SDU and Danish taxpayers.\n                  Based on the market coverage, there is only one supplier who can deliver the desired\n                  equipment.</span></section>\n            <section><span class=\"label\">Identifikator for proceduren</span><span class=\"text\">: </span><span class=\"value\">2cdf83fc-c467-4b67-b77e-fe5efa85efd7</span></section>\n            <section><span class=\"label\">Tidligere bekendtgørelse</span><span class=\"text\">: </span><span class=\"value\">586950-2026</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">784111</span></section>\n            <section><span class=\"label\">Udbudsprocedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Udbud med forhandling uden forudgående offentliggørelse</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38970000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Simulatorer til forskning, prøvning eller teknisk-videnskabelig brug</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratorieudstyr, optisk udstyr og præcisionsudstyr (ikke briller)</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\">The low vibration, high vacuum cryostat, with vector magnet can only be supplied by\n                     Qnity SAS because it is the only known commercial supplier of a system with these\n                     technical specifications. There is an objective and proportionate reason for the establishment\n                     of <br/>specifications which result in there being only one supplier. The possibility\n                     that there are other <br/>potential suppliers who could deliver the same has been\n                     objectively excluded by market <br/>consultations.</span></section>\n               <section><span class=\"label\">Retsgrundlag</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Direktiv 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Delkontrakt</span><section>5.1&nbsp;<span class=\"label\">Delkontrakt</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Low vibration, high vacuum cryostat, with vector magnet for SDU</span></section>\n            <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                  vacuum, vibration, electrical, and future upgrade requirements that are essential\n                  for our research. Following a market assessment, only the proposed supplier was identified\n                  as capable of providing a fully integrated system meeting all mandatory specifications.<br/><br/>1.\n                  Product Specifications Required<br/><br/>The system must provide:<br/><br/>•At least\n                  four lateral optical accesses and one top optical access.<br/><br/>•A large cryogenic\n                  sample volume of Ø250 mm cold plate × 250 mm height.<br/><br/>•Non-magnetic radiation\n                  shield with four horizontal and one vertical optical window.<br/><br/>•Three integrated\n                  50 A high-current channels to the 4 K stage.<br/><br/>•Four thermally anchored coaxial\n                  lines for measurements up to 20 GHz.<br/><br/>•Four fibre-optic feedthroughs.<br/><br/>•48\n                  DC electrical connections at the 4 K cold plate.<br/><br/>•Base temperature ≤ 3.5\n                  K with stability better than 50 mK.<br/><br/>•Cooling power of at least 250 mW at\n                  4.2 K.<br/><br/>•Vibration levels below 30 nm peak-to-peak.<br/><br/>•Ultra-high vacuum\n                  better than 1 × 10⁻⁹ mbar.<br/><br/>•Remote cryocooler architecture with unrestricted\n                  360° optical access.<br/><br/>•Future compatibility with a removable 4-1-1 vector\n                  magnet.<br/><br/>•Complete mobility of the cryostat on the optical table.<br/><br/>2.\n                  Why These Specifications Are Necessary<br/><br/>•Large 250 mm sample space: Required\n                  to accommodate complex optical setups, cryogenic positioners, electrical and fibre\n                  connections, and future magnet integration without redesigning the experimental platform.<br/><br/>•Ultra-high\n                  vacuum (UHV): Our experiments run continuously for several weeks. A vacuum level better\n                  than 1 × 10⁻⁹ mbar is essential to avoid contamination of samples and optical windows,\n                  ensuring stable measurement conditions and reproducible results over long measurement\n                  periods.<br/><br/>•Remote cryocooler and ultra-low vibration: Our experiments rely\n                  on interferometric and other vibration-sensitive optical measurements. The cryocooler\n                  must be physically separated from the optical table to minimise vibration and acoustic\n                  noise transmission, while maintaining the flexibility to move the cryostat when experimental\n                  configurations evolve.<br/><br/>•Extensive optical access: Four side windows and one\n                  top window are required to provide simultaneous laser excitation, imaging, collection\n                  optics, and future experimental configurations that cannot be accommodated by standard\n                  cryostat designs.<br/><br/>•Future magnet integration: The system must support straightforward\n                  integration of a 4-1-1 vector magnet and allow different magnet configurations to\n                  be installed or removed without major modifications to the cryostat.<br/><br/>3. Why\n                  There Is Only One Supplier<br/><br/>The selected supplier is the only identified manufacturer\n                  capable of providing all required features within one validated and integrated platform.<br/><br/>In\n                  particular, the supplier uniquely combines:<br/><br/>•A Ø250 mm × 250 mm cryogenic\n                  sample space.<br/><br/>•UHV performance (&lt;10⁻⁹ mbar) suitable for multi-week experiments.<br/><br/>•A\n                  remote cryocooler architecture delivering very low vibration while preserving cryostat\n                  mobility.<br/><br/>•Unobstructed 360° optical access with multiple optical ports.<br/><br/>•Integrated\n                  high-current, RF, fibre-optic, and DC measurement infrastructure.<br/><br/>•A design\n                  specifically prepared for future vector magnet integration and compatibility with\n                  different magnet configurations.<br/><br/>•Cryogenic positioners and cryostat supplied\n                  by the same manufacturer, ensuring full mechanical, thermal, electrical, and software\n                  compatibility while eliminating integration risks.<br/><br/>Although alternative suppliers\n                  may offer some individual features, no other supplier was found that can simultaneously\n                  provide the required UHV performance, large sample volume, remote low-vibration architecture,\n                  extensive optical access, future magnet flexibility, and fully integrated cryogenic\n                  positioning system. We have nonetheless ensured that the terms of acquisition reflect\n                  sound financial judgment and serve the best interests of SDU and Danish taxpayers.\n                  Based on the market coverage, there is only one supplier who can deliver the desired\n                  equipment.</span></section>\n            <section><span class=\"label\">Intern ID</span><span class=\"text\">: </span><span class=\"value\">784111</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Formål</span><section><span class=\"label\">Kontraktens hovedformål</span><span class=\"text\">: </span><span class=\"dynamic-label\">Varer</span></section>\n               <section><span class=\"label\">Primær klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38970000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Simulatorer til forskning, prøvning eller teknisk-videnskabelig brug</span></section>\n               <section><span class=\"label\">Supplerende klassifikation</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratorieudstyr, optisk udstyr og præcisionsudstyr (ikke briller)</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Udførelsessted</span><section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n               <section><span class=\"label\">Yderligere oplysninger</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.4&nbsp;<span class=\"label\">Fornyelse</span><section><span class=\"label\">Højeste antal fornyelser</span><span class=\"text\">: </span><span class=\"value\">0</span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">Generelle oplysninger</span><section><span class=\"dynamic-label\">Indkøbsprojekt, der ikke finansieres med EU-midler</span></section>\n               <section><span class=\"label\">Udbuddet er omfattet af aftalen om offentlige udbud (GPA)</span><span class=\"text\">: </span><span class=\"label\">ja</span></section>\n            </section>\n            <section>5.1.10&nbsp;<span class=\"label\">Tildelingskriterier</span><section><span class=\"label\">Kriterium</span><span class=\"text\">:</span><section><span class=\"label\">Type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kvalitet</span></section>\n                  <section><span class=\"label\">Beskrivelse</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                        vacuum, vibration, electrical, and future upgrade requirements that are essential\n                        for our research. Following a market assessment, only the proposed supplier was identified\n                        as capable of providing a fully integrated system meeting all mandatory specifications.<br/>1.\n                        Product Specifications Required<br/>The system must provide:<br/>• At least four lateral\n                        optical accesses and one top optical access.<br/>• A large cryogenic sample volume\n                        of Ø250 mm cold plate × 250 mm height.<br/>• Non-magnetic radiation shield with four\n                        horizontal and one vertical optical window.<br/>• Three integrated 50 A high-current\n                        channels to the 4 K stage.<br/>• Four thermally anchored coaxial lines for measurements\n                        up to 20 GHz.<br/>• Four fibre-optic feedthroughs.<br/>• 48 DC electrical connections\n                        at the 4 K cold plate.<br/>• Base temperature ≤ 3.5 K with stability better than 50\n                        mK.<br/>• Cooling power of at least 250 mW at 4.2 K.<br/>• Vibration levels below\n                        30 nm peak-to-peak.<br/>• Ultra-high vacuum better than 1 × 10⁻⁹ mbar.<br/>• Remote\n                        cryocooler architecture with unrestricted 360° optical access.<br/>• Future compatibility\n                        with a removable 4-1-1 vector magnet.<br/>• Complete mobility of the cryostat on the\n                        optical table.<br/><br/>2. Why These Specifications Are Necessary<br/>• Large 250\n                        mm sample space: Required to accommodate complex optical setups, cryogenic positioners,\n                        electrical and fibre connections, and future magnet integration without redesigning\n                        the experimental platform.<br/>• Ultra-high vacuum (UHV): Our experiments run continuously\n                        for several weeks. A vacuum level better than 1 × 10⁻⁹ mbar is essential to avoid\n                        contamination of samples and optical windows, ensuring stable measurement conditions\n                        and reproducible results over long measurement periods.<br/>• Remote cryocooler and\n                        ultra-low vibration: Our experiments rely on interferometric and other vibration-sensitive\n                        optical measurements. The cryocooler must be physically separated from the optical\n                        table to minimise vibration and acoustic noise transmission, while maintaining the\n                        flexibility to move the cryostat when experimental configurations evolve.<br/>• Extensive\n                        optical access: Four side windows and one top window are required to provide simultaneous\n                        laser excitation, imaging, collection optics, and future experimental configurations\n                        that cannot be accommodated by standard cryostat designs.<br/>• Future magnet integration:\n                        The system must support straightforward integration of a 4-1-1 vector magnet and allow\n                        different magnet configurations to be installed or removed without major modifications\n                        to the cryostat.<br/><br/>3. Why There Is Only One Supplier<br/>The selected supplier\n                        is the only identified manufacturer capable of providing all required features within\n                        one validated and integrated platform.<br/>In particular, the supplier uniquely combines:<br/>•\n                        A Ø250 mm × 250 mm cryogenic sample space.<br/>• UHV performance (&lt;10⁻⁹ mbar) suitable\n                        for multi-week experiments.<br/>• A remote cryocooler architecture delivering very\n                        low vibration while preserving cryostat mobility.<br/>• Unobstructed 360° optical\n                        access with multiple optical ports.<br/>• Integrated high-current, RF, fibre-optic,\n                        and DC measurement infrastructure.<br/>• A design specifically prepared for future\n                        vector magnet integration and compatibility with different magnet configurations.<br/>•\n                        Cryogenic positioners and cryostat supplied by the same manufacturer, ensuring full\n                        mechanical, thermal, electrical, and software compatibility while eliminating integration\n                        risks.<br/><br/>Although alternative suppliers may offer some individual features,\n                        no other supplier was found that can simultaneously provide the required UHV performance,\n                        large sample volume, remote low-vibration architecture, extensive optical access,\n                        future magnet flexibility, and fully integrated cryogenic positioning system. We have\n                        nonetheless ensured that the terms of acquisition reflect sound financial judgment\n                        and serve the best interests of SDU and Danish taxpayers. Based on the market coverage,\n                        there is only one supplier who can deliver the desired equipment.<br/></span></section>\n                  <section><span class=\"label\">Kategori for tildelingskriteriet vægt</span><span class=\"text\">: </span><span class=\"dynamic-label\">Vægtning (pointantal, præcis)</span><section><span class=\"label\">Tildelingskriterium talværdi</span><span class=\"text\">: </span><span class=\"value\">100</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>5.1.15&nbsp;<span class=\"label\">Teknikker</span><section><span class=\"label\">Rammeaftale</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">Ingen rammeaftale</span></section>\n               </section>\n               <section><span class=\"label\">Oplysninger om det dynamiske indkøbssystem</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">Intet dynamisk indkøbssystem</span></section>\n               </section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Yderligere oplysninger, mægling og gennemgang</span><section><span class=\"label\">Organisation med ansvar for klager</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Oplysninger om klagefrister</span><span class=\"text\">: </span><span class=\"value\">I henhold til lov om Klagenævnet for Udbud gælder følgende frist for indgivelse af\n                     klage:<br/>Klage over ikke at være blevet prækvalificeret skal være indgivet til Klagenævnet\n                     for Udbud inden 20 kalenderdage fra dagen efter afsendelse af en underretning til\n                     de berørte ansøgere om, hvem der er blevet udvalgt, jf. udbudslovens § 171, stk. 2,\n                     eller klagenævnslovens § 2, stk. 1, nr. 1, når underretningen er ledsaget af en begrundelse\n                     for beslutningen.<br/>I andre situationer skal klage over udbud være indgivet til\n                     Klagenævnet for Udbud inden:<br/><br/>1) 45 kalenderdage efter, at ordregiveren har\n                     offentliggjort en bekendtgørelse i Den Europæiske Unions Tidende om, at ordregiveren\n                     har indgået en kontrakt. Fristen regnes fra dagen efter den dag, hvor bekendtgørelsen\n                     er blevet offentliggjort.<br/>2) 30 kalenderdage regnet fra dagen efter den dag, hvor\n                     ordregiveren har underrettet de berørte tilbudsgivere om, at en kontrakt baseret på\n                     en rammeaftale med genåbning af konkurrencen eller et dynamisk indkøbssystem er indgået,\n                     hvis underretningen har angivet en begrundelse for beslutningen.<br/>3) seks måneder\n                     efter, at ordregiveren har indgået en rammeaftale, regnet fra dagen efter den dag,\n                     hvor ordregiveren har underrettet de berørte ansøgere og tilbudsgivere, jf. klagenævnslovens\n                     § 2, stk. 2, eller udbudslovens § 171, stk. 4.<br/>4) 20 kalenderdage regnet fra dagen\n                     efter, at ordregiveren har meddelt sin beslutning, jf. udbudslovens § 185, stk. 2.<br/><br/>Senest\n                     samtidig med at en klage indgives til Klagenævnet for Udbud, skal klageren skriftligt\n                     underrette ordregiveren om, at en klage indgives til Klagenævnet for Udbud, og om,\n                     hvorvidt klagen er indgivet i standstill-perioden, jf. klagenævnslovens § 6, stk.\n                     4. I tilfælde, hvor klagen ikke er indgivet i standstill-perioden, skal klageren tillige\n                     angive, hvorvidt der begæres opsættende virkning af klagen, jf. klagenævnslovens §\n                     12, stk. 1.</span></section>\n               <section><span class=\"label\">Organisation, der leverer supplerende oplysninger om udbudsproceduren</span><span class=\"text\">: </span><span class=\"value\">Syddansk Universitet</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Resultater</span><section><span class=\"label\">Værdien af alle kontrakter tildelt i denne bekendtgørelse</span><span class=\"text\">: </span><span class=\"value\">3.319.273</span><span class=\"text\"> </span><span class=\"label\">Dansk krone</span></section>\n         <section><span class=\"label\">Direkte tildeling</span><span class=\"text\">:</span><section><span class=\"label\">Begrundelse for direkte tildeling</span><span class=\"text\">: </span><span class=\"dynamic-label\">Kontrakten kan kun tildeles af en bestemt økonomisk aktør på grund af manglende konkurrence af tekniske årsager</span></section>\n            <section><span class=\"label\">Anden begrundelse</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                  vacuum, vibration, electrical, and future upgrade requirements that are essential\n                  for our research. Following a market assessment, only the proposed supplier was identified\n                  as capable of providing a fully integrated system meeting all mandatory specifications.<br/>1.\n                  Product Specifications Required<br/>The system must provide:<br/>• At least four lateral\n                  optical accesses and one top optical access.<br/>• A large cryogenic sample volume\n                  of Ø250 mm cold plate × 250 mm height.<br/>• Non-magnetic radiation shield with four\n                  horizontal and one vertical optical window.<br/>• Three integrated 50 A high-current\n                  channels to the 4 K stage.<br/>• Four thermally anchored coaxial lines for measurements\n                  up to 20 GHz.<br/>• Four fibre-optic feedthroughs.<br/>• 48 DC electrical connections\n                  at the 4 K cold plate.<br/>• Base temperature ≤ 3.5 K with stability better than 50\n                  mK.<br/>• Cooling power of at least 250 mW at 4.2 K.<br/>• Vibration levels below\n                  30 nm peak-to-peak.<br/>• Ultra-high vacuum better than 1 × 10⁻⁹ mbar.<br/>• Remote\n                  cryocooler architecture with unrestricted 360° optical access.<br/>• Future compatibility\n                  with a removable 4-1-1 vector magnet.<br/>• Complete mobility of the cryostat on the\n                  optical table.<br/><br/>2. Why These Specifications Are Necessary<br/>• Large 250\n                  mm sample space: Required to accommodate complex optical setups, cryogenic positioners,\n                  electrical and fibre connections, and future magnet integration without redesigning\n                  the experimental platform.<br/>• Ultra-high vacuum (UHV): Our experiments run continuously\n                  for several weeks. A vacuum level better than 1 × 10⁻⁹ mbar is essential to avoid\n                  contamination of samples and optical windows, ensuring stable measurement conditions\n                  and reproducible results over long measurement periods.<br/>• Remote cryocooler and\n                  ultra-low vibration: Our experiments rely on interferometric and other vibration-sensitive\n                  optical measurements. The cryocooler must be physically separated from the optical\n                  table to minimise vibration and acoustic noise transmission, while maintaining the\n                  flexibility to move the cryostat when experimental configurations evolve.<br/>• Extensive\n                  optical access: Four side windows and one top window are required to provide simultaneous\n                  laser excitation, imaging, collection optics, and future experimental configurations\n                  that cannot be accommodated by standard cryostat designs.<br/><br/>• Future magnet\n                  integration: The system must support straightforward integration of a 4-1-1 vector\n                  magnet and allow different magnet configurations to be installed or removed without\n                  major modifications to the cryostat.<br/>3. Why There Is Only One Supplier<br/>The\n                  selected supplier is the only identified manufacturer capable of providing all required\n                  features within one validated and integrated platform.<br/>In particular, the supplier\n                  uniquely combines:<br/>• A Ø250 mm × 250 mm cryogenic sample space.<br/>• UHV performance\n                  (&lt;10⁻⁹ mbar) suitable for multi-week experiments.<br/>• A remote cryocooler architecture\n                  delivering very low vibration while preserving cryostat mobility.<br/>• Unobstructed\n                  360° optical access with multiple optical ports.<br/>• Integrated high-current, RF,\n                  fibre-optic, and DC measurement infrastructure.<br/>• A design specifically prepared\n                  for future vector magnet integration and compatibility with different magnet configurations.<br/>•\n                  Cryogenic positioners and cryostat supplied by the same manufacturer, ensuring full\n                  mechanical, thermal, electrical, and software compatibility while eliminating integration\n                  risks.<br/><br/>Although alternative suppliers may offer some individual features,\n                  no other supplier was found that can simultaneously provide the required UHV performance,\n                  large sample volume, remote low-vibration architecture, extensive optical access,\n                  future magnet flexibility, and fully integrated cryogenic positioning system. We have\n                  nonetheless ensured that the terms of acquisition reflect sound financial judgment\n                  and serve the best interests of SDU and Danish taxpayers. Based on the market coverage,\n                  there is only one supplier who can deliver the desired equipment.<br/></span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Resultat delkontrakt-ID</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"dynamic-label\">Der er udvalgt mindst én vinder.</span></section>\n            <section>6.1.2&nbsp;<span class=\"label\">Oplysninger om vinderne</span><section><span class=\"label\">Vinder</span><span class=\"text\">:</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Qnity SAS</span></section>\n                  <section><span class=\"label\">Tilbud</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tilbud – Identifikator</span><span class=\"text\">: </span><span class=\"value\">132295</span></section>\n                  <section><span class=\"label\">ID for delkontrakt eller gruppe af delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Værdien af tilbuddet</span><span class=\"text\">: </span><span class=\"value\">3.319.273</span><span class=\"text\"> </span><span class=\"dynamic-label\">Dansk krone</span></section>\n                  <section><span class=\"label\">Underentreprise</span><span class=\"text\">: </span><span class=\"dynamic-label\">Nej</span></section>\n                  <section><span class=\"label\">Kontraktoplysninger</span><span class=\"text\">:</span><section><span class=\"label\">Identifikator for kontrakten</span><span class=\"text\">: </span><span class=\"value\">132295</span></section>\n                     <section><span class=\"label\">Titel</span><span class=\"text\">: </span><span class=\"value\">Low vibration, high vacuum cryostat, with vector magnet for SDU / Qnity SAS</span></section>\n                     <section><span class=\"label\">Datoen for udvælgelsen af det vindende tilbud</span><span class=\"text\">: </span><span class=\"value\">11-08-2026</span></section>\n                     <section><span class=\"label\">Dato for indgåelse af kontrakten</span><span class=\"text\">: </span><span class=\"value\">07-09-2026</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>6.1.4&nbsp;<span class=\"label\">Statistiske oplysninger</span><section><span class=\"label\">Modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">:</span><section><span class=\"label\">Type modtagne indgivelser</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tilbud</span><section><span class=\"label\">Antal modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n                  <section><span class=\"label\">Type modtagne indgivelser</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tilbud fra mikrovirksomheder samt små eller mellemstore virksomheder</span><section><span class=\"label\">Antal modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n                  <section><span class=\"label\">Type modtagne indgivelser</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tilbud fra tilbudsgivere, der er registreret i lande uden for EØS</span><section><span class=\"label\">Antal modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">: </span><span class=\"value\">0</span></section>\n                  </section>\n                  <section><span class=\"label\">Type modtagne indgivelser</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tilbud, der er indgivet ad elektronisk vej</span><section><span class=\"label\">Antal modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n                  <section><span class=\"label\">Type modtagne indgivelser</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tilbud fra tilbudsgivere, der er registreret i andre EØS-lande end købers land</span><section><span class=\"label\">Antal modtagne tilbud og ansøgninger om deltagelse</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisationer</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Syddansk Universitet</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">29283958</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Campusvej 55</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Odense M</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">5230</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">Enhed</span><span class=\"text\">: </span><span class=\"value\">Christina From-Nielsen</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">cfro@sdu.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">65509484</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.sdu.dk/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Køber</span></section>\n               <section><span class=\"label\">Organisation, der leverer supplerende oplysninger om udbudsproceduren</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-1000</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Comdia ApS</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">33501404</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Lindvedvej 71</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Odense S</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">5260</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">support@comdia.com</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 7199 3672</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.comdia.com/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-1001</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Nævnenes Hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Vestjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK041</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">klfu@naevneneshus.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 7240 5600</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation med ansvar for klager</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-1002</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danmark</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+45 4171 5000</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://www.kfst.dk/</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Organisation, der leverer yderligere oplysninger om klageprocedurerne</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Officielt navn</span><span class=\"text\">: </span><span class=\"value\">Qnity SAS</span></section>\n            <section><span class=\"label\">Den økonomiske operatørs størrelse</span><span class=\"text\">: </span><span class=\"label\">Mellemstor virksomhed</span></section>\n            <section><span class=\"label\">Registreringsnummer</span><span class=\"text\">: </span><span class=\"value\">FR15939451985</span></section>\n            <section><span class=\"label\">Postadresse</span><span class=\"text\">: </span><span class=\"value\">42 BIS RUE THEODORE DE BANVILLE</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">By</span><span class=\"text\">: </span><span class=\"value\">PALAISEAU</span></section>\n            <section><span class=\"label\">Postnummer</span><span class=\"text\">: </span><span class=\"value\">91120</span></section>\n            <section><span class=\"label\">Landsdel (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Essonne</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">FR104</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Land</span><span class=\"text\">: </span><span class=\"dynamic-label\">Frankrig</span></section>\n            <section><span class=\"label\">E-mail</span><span class=\"text\">: </span><span class=\"value\">caby@qnity.io</span></section>\n            <section><span class=\"label\">Telefon</span><span class=\"text\">: </span><span class=\"value\">+33667770474</span></section>\n            <section><span class=\"label\">Internetadresse</span><span class=\"text\">: </span><span class=\"value\">https://qnity.io</span></section>\n            <section><span class=\"label\">Denne organisations roller</span><span class=\"text\">:</span><section><span class=\"label\">Tilbudsgiver</span></section>\n               <section><span class=\"label\">Vinder af disse delkontrakter</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Oplysninger om bekendtgørelsen</span><section><span class=\"label\">Bekendtgørelsens ID</span><span class=\"text\">: </span><span class=\"value\">048492d6-e305-46b0-879a-c9be10911af9</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Formulartype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Resultater</span></section>\n         <section><span class=\"label\">Bekendtgørelsestype</span><span class=\"text\">: </span><span class=\"dynamic-label\">Bekendtgørelse om indgåede kontrakter eller koncessionstildeling – standardordningen</span></section>\n         <section><span class=\"label\">Afsendelsesdato for bekendtgørelsen</span><span class=\"text\">: </span><span class=\"value\">07-09-2026</span><span class=\"text\"> </span><span class=\"value\">13:49 +02:00</span></section>\n         <section><span class=\"label\">Bekendtgørelsens officielle sprog</span><span class=\"text\">: </span><span class=\"dynamic-label\">dansk</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Bekendtgørelsesnummer</span><span class=\"text\">: </span><span class=\"value\">00616391-2026</span></section>\n         <section><span class=\"label\">EUT-S-nummer</span><span class=\"text\">: </span><span class=\"value\">173/2026</span></section>\n         <section><span class=\"label\">Offentliggørelsesdato</span><span class=\"text\">: </span><span class=\"value\">08-09-2026</span></section>\n      </section>\n   </body>\n</html>","htmlEN":"<!DOCTYPE HTML>\n<html xmlns:cac=\"urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2\" xmlns:cbc=\"urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2\" xmlns:efac=\"http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1\" xmlns:efbc=\"http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1\" xmlns:efext=\"http://data.europa.eu/p27/eforms-ubl-extensions/1\" xmlns:ext=\"urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2\" xmlns:fn=\"http://www.w3.org/2005/xpath-functions\" xmlns:xs=\"http://www.w3.org/2001/XMLSchema\">\n   <body>\n      <section>1&nbsp;<span class=\"label\">Buyer</span><section>1.1&nbsp;<span class=\"label\">Buyer</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Syddansk Universitet</span></section>\n            <section><span class=\"label\">Legal type of the buyer</span><span class=\"text\">: </span><span class=\"dynamic-label\">Body governed by public law</span></section>\n            <section><span class=\"label\">Activity of the contracting authority</span><span class=\"text\">: </span><span class=\"dynamic-label\">Education</span></section>\n         </section>\n      </section>\n      <section>2&nbsp;<span class=\"label\">Procedure</span><section>2.1&nbsp;<span class=\"label\">Procedure</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Low vibration, high vacuum cryostat, with vector magnet for SDU</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                  vacuum, vibration, electrical, and future upgrade requirements that are essential\n                  for our research. Following a market assessment, only the proposed supplier was identified\n                  as capable of providing a fully integrated system meeting all mandatory specifications.<br/><br/>1.\n                  Product Specifications Required<br/><br/>The system must provide:<br/><br/>•At least\n                  four lateral optical accesses and one top optical access.<br/><br/>•A large cryogenic\n                  sample volume of Ø250 mm cold plate × 250 mm height.<br/><br/>•Non-magnetic radiation\n                  shield with four horizontal and one vertical optical window.<br/><br/>•Three integrated\n                  50 A high-current channels to the 4 K stage.<br/><br/>•Four thermally anchored coaxial\n                  lines for measurements up to 20 GHz.<br/><br/>•Four fibre-optic feedthroughs.<br/><br/>•48\n                  DC electrical connections at the 4 K cold plate.<br/><br/>•Base temperature ≤ 3.5\n                  K with stability better than 50 mK.<br/><br/>•Cooling power of at least 250 mW at\n                  4.2 K.<br/><br/>•Vibration levels below 30 nm peak-to-peak.<br/><br/>•Ultra-high vacuum\n                  better than 1 × 10⁻⁹ mbar.<br/><br/>•Remote cryocooler architecture with unrestricted\n                  360° optical access.<br/><br/>•Future compatibility with a removable 4-1-1 vector\n                  magnet.<br/><br/>•Complete mobility of the cryostat on the optical table.<br/><br/>2.\n                  Why These Specifications Are Necessary<br/><br/>•Large 250 mm sample space: Required\n                  to accommodate complex optical setups, cryogenic positioners, electrical and fibre\n                  connections, and future magnet integration without redesigning the experimental platform.<br/><br/>•Ultra-high\n                  vacuum (UHV): Our experiments run continuously for several weeks. A vacuum level better\n                  than 1 × 10⁻⁹ mbar is essential to avoid contamination of samples and optical windows,\n                  ensuring stable measurement conditions and reproducible results over long measurement\n                  periods.<br/><br/>•Remote cryocooler and ultra-low vibration: Our experiments rely\n                  on interferometric and other vibration-sensitive optical measurements. The cryocooler\n                  must be physically separated from the optical table to minimise vibration and acoustic\n                  noise transmission, while maintaining the flexibility to move the cryostat when experimental\n                  configurations evolve.<br/><br/>•Extensive optical access: Four side windows and one\n                  top window are required to provide simultaneous laser excitation, imaging, collection\n                  optics, and future experimental configurations that cannot be accommodated by standard\n                  cryostat designs.<br/><br/>•Future magnet integration: The system must support straightforward\n                  integration of a 4-1-1 vector magnet and allow different magnet configurations to\n                  be installed or removed without major modifications to the cryostat.<br/><br/>3. Why\n                  There Is Only One Supplier<br/><br/>The selected supplier is the only identified manufacturer\n                  capable of providing all required features within one validated and integrated platform.<br/><br/>In\n                  particular, the supplier uniquely combines:<br/><br/>•A Ø250 mm × 250 mm cryogenic\n                  sample space.<br/><br/>•UHV performance (&lt;10⁻⁹ mbar) suitable for multi-week experiments.<br/><br/>•A\n                  remote cryocooler architecture delivering very low vibration while preserving cryostat\n                  mobility.<br/><br/>•Unobstructed 360° optical access with multiple optical ports.<br/><br/>•Integrated\n                  high-current, RF, fibre-optic, and DC measurement infrastructure.<br/><br/>•A design\n                  specifically prepared for future vector magnet integration and compatibility with\n                  different magnet configurations.<br/><br/>•Cryogenic positioners and cryostat supplied\n                  by the same manufacturer, ensuring full mechanical, thermal, electrical, and software\n                  compatibility while eliminating integration risks.<br/><br/>Although alternative suppliers\n                  may offer some individual features, no other supplier was found that can simultaneously\n                  provide the required UHV performance, large sample volume, remote low-vibration architecture,\n                  extensive optical access, future magnet flexibility, and fully integrated cryogenic\n                  positioning system. We have nonetheless ensured that the terms of acquisition reflect\n                  sound financial judgment and serve the best interests of SDU and Danish taxpayers.\n                  Based on the market coverage, there is only one supplier who can deliver the desired\n                  equipment.</span></section>\n            <section><span class=\"label\">Procedure identifier</span><span class=\"text\">: </span><span class=\"value\">2cdf83fc-c467-4b67-b77e-fe5efa85efd7</span></section>\n            <section><span class=\"label\">Previous notice</span><span class=\"text\">: </span><span class=\"value\">586950-2026</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">784111</span></section>\n            <section><span class=\"label\">Type of procedure</span><span class=\"text\">: </span><span class=\"dynamic-label\">Negotiated without prior call for competition</span></section>\n            <section>2.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38970000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Research, testing and scientific technical simulator</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratory, optical and precision equipments (excl. glasses)</span></section>\n            </section>\n            <section>2.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            </section>\n            <section>2.1.4&nbsp;<span class=\"label\">General information</span><section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\">The low vibration, high vacuum cryostat, with vector magnet can only be supplied by\n                     Qnity SAS because it is the only known commercial supplier of a system with these\n                     technical specifications. There is an objective and proportionate reason for the establishment\n                     of <br/>specifications which result in there being only one supplier. The possibility\n                     that there are other <br/>potential suppliers who could deliver the same has been\n                     objectively excluded by market <br/>consultations.</span></section>\n               <section><span class=\"label\">Legal basis</span><span class=\"text\">:</span></section>\n               <section><span class=\"dynamic-label\">Directive 2014/24/EU</span></section>\n            </section>\n         </section>\n      </section>\n      <section>5&nbsp;<span class=\"label\">Lot</span><section>5.1&nbsp;<span class=\"label\">Lot</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Low vibration, high vacuum cryostat, with vector magnet for SDU</span></section>\n            <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                  vacuum, vibration, electrical, and future upgrade requirements that are essential\n                  for our research. Following a market assessment, only the proposed supplier was identified\n                  as capable of providing a fully integrated system meeting all mandatory specifications.<br/><br/>1.\n                  Product Specifications Required<br/><br/>The system must provide:<br/><br/>•At least\n                  four lateral optical accesses and one top optical access.<br/><br/>•A large cryogenic\n                  sample volume of Ø250 mm cold plate × 250 mm height.<br/><br/>•Non-magnetic radiation\n                  shield with four horizontal and one vertical optical window.<br/><br/>•Three integrated\n                  50 A high-current channels to the 4 K stage.<br/><br/>•Four thermally anchored coaxial\n                  lines for measurements up to 20 GHz.<br/><br/>•Four fibre-optic feedthroughs.<br/><br/>•48\n                  DC electrical connections at the 4 K cold plate.<br/><br/>•Base temperature ≤ 3.5\n                  K with stability better than 50 mK.<br/><br/>•Cooling power of at least 250 mW at\n                  4.2 K.<br/><br/>•Vibration levels below 30 nm peak-to-peak.<br/><br/>•Ultra-high vacuum\n                  better than 1 × 10⁻⁹ mbar.<br/><br/>•Remote cryocooler architecture with unrestricted\n                  360° optical access.<br/><br/>•Future compatibility with a removable 4-1-1 vector\n                  magnet.<br/><br/>•Complete mobility of the cryostat on the optical table.<br/><br/>2.\n                  Why These Specifications Are Necessary<br/><br/>•Large 250 mm sample space: Required\n                  to accommodate complex optical setups, cryogenic positioners, electrical and fibre\n                  connections, and future magnet integration without redesigning the experimental platform.<br/><br/>•Ultra-high\n                  vacuum (UHV): Our experiments run continuously for several weeks. A vacuum level better\n                  than 1 × 10⁻⁹ mbar is essential to avoid contamination of samples and optical windows,\n                  ensuring stable measurement conditions and reproducible results over long measurement\n                  periods.<br/><br/>•Remote cryocooler and ultra-low vibration: Our experiments rely\n                  on interferometric and other vibration-sensitive optical measurements. The cryocooler\n                  must be physically separated from the optical table to minimise vibration and acoustic\n                  noise transmission, while maintaining the flexibility to move the cryostat when experimental\n                  configurations evolve.<br/><br/>•Extensive optical access: Four side windows and one\n                  top window are required to provide simultaneous laser excitation, imaging, collection\n                  optics, and future experimental configurations that cannot be accommodated by standard\n                  cryostat designs.<br/><br/>•Future magnet integration: The system must support straightforward\n                  integration of a 4-1-1 vector magnet and allow different magnet configurations to\n                  be installed or removed without major modifications to the cryostat.<br/><br/>3. Why\n                  There Is Only One Supplier<br/><br/>The selected supplier is the only identified manufacturer\n                  capable of providing all required features within one validated and integrated platform.<br/><br/>In\n                  particular, the supplier uniquely combines:<br/><br/>•A Ø250 mm × 250 mm cryogenic\n                  sample space.<br/><br/>•UHV performance (&lt;10⁻⁹ mbar) suitable for multi-week experiments.<br/><br/>•A\n                  remote cryocooler architecture delivering very low vibration while preserving cryostat\n                  mobility.<br/><br/>•Unobstructed 360° optical access with multiple optical ports.<br/><br/>•Integrated\n                  high-current, RF, fibre-optic, and DC measurement infrastructure.<br/><br/>•A design\n                  specifically prepared for future vector magnet integration and compatibility with\n                  different magnet configurations.<br/><br/>•Cryogenic positioners and cryostat supplied\n                  by the same manufacturer, ensuring full mechanical, thermal, electrical, and software\n                  compatibility while eliminating integration risks.<br/><br/>Although alternative suppliers\n                  may offer some individual features, no other supplier was found that can simultaneously\n                  provide the required UHV performance, large sample volume, remote low-vibration architecture,\n                  extensive optical access, future magnet flexibility, and fully integrated cryogenic\n                  positioning system. We have nonetheless ensured that the terms of acquisition reflect\n                  sound financial judgment and serve the best interests of SDU and Danish taxpayers.\n                  Based on the market coverage, there is only one supplier who can deliver the desired\n                  equipment.</span></section>\n            <section><span class=\"label\">Internal identifier</span><span class=\"text\">: </span><span class=\"value\">784111</span></section>\n            <section>5.1.1&nbsp;<span class=\"label\">Purpose</span><section><span class=\"label\">Main nature of the contract</span><span class=\"text\">: </span><span class=\"dynamic-label\">Supplies</span></section>\n               <section><span class=\"label\">Main classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38970000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Research, testing and scientific technical simulator</span></section>\n               <section><span class=\"label\">Additional classification</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">cpv</span><span class=\"text\">): </span><span class=\"value\">38000000</span><span class=\"text\"> </span><span class=\"dynamic-label\">Laboratory, optical and precision equipments (excl. glasses)</span></section>\n            </section>\n            <section>5.1.2&nbsp;<span class=\"label\">Place of performance</span><section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n               <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n               <section><span class=\"label\">Additional information</span><span class=\"text\">: </span><span class=\"value\"></span></section>\n            </section>\n            <section>5.1.4&nbsp;<span class=\"label\">Renewal</span><section><span class=\"label\">Maximum renewals</span><span class=\"text\">: </span><span class=\"value\">0</span></section>\n            </section>\n            <section>5.1.6&nbsp;<span class=\"label\">General information</span><section><span class=\"dynamic-label\">Procurement Project not financed with EU Funds.</span></section>\n               <section><span class=\"label\">The procurement is covered by the Government Procurement Agreement (GPA)</span><span class=\"text\">: </span><span class=\"label\">yes</span></section>\n            </section>\n            <section>5.1.10&nbsp;<span class=\"label\">Award criteria</span><section><span class=\"label\">Criterion</span><span class=\"text\">:</span><section><span class=\"label\">Type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Quality</span></section>\n                  <section><span class=\"label\">Description</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                        vacuum, vibration, electrical, and future upgrade requirements that are essential\n                        for our research. Following a market assessment, only the proposed supplier was identified\n                        as capable of providing a fully integrated system meeting all mandatory specifications.<br/>1.\n                        Product Specifications Required<br/>The system must provide:<br/>• At least four lateral\n                        optical accesses and one top optical access.<br/>• A large cryogenic sample volume\n                        of Ø250 mm cold plate × 250 mm height.<br/>• Non-magnetic radiation shield with four\n                        horizontal and one vertical optical window.<br/>• Three integrated 50 A high-current\n                        channels to the 4 K stage.<br/>• Four thermally anchored coaxial lines for measurements\n                        up to 20 GHz.<br/>• Four fibre-optic feedthroughs.<br/>• 48 DC electrical connections\n                        at the 4 K cold plate.<br/>• Base temperature ≤ 3.5 K with stability better than 50\n                        mK.<br/>• Cooling power of at least 250 mW at 4.2 K.<br/>• Vibration levels below\n                        30 nm peak-to-peak.<br/>• Ultra-high vacuum better than 1 × 10⁻⁹ mbar.<br/>• Remote\n                        cryocooler architecture with unrestricted 360° optical access.<br/>• Future compatibility\n                        with a removable 4-1-1 vector magnet.<br/>• Complete mobility of the cryostat on the\n                        optical table.<br/><br/>2. Why These Specifications Are Necessary<br/>• Large 250\n                        mm sample space: Required to accommodate complex optical setups, cryogenic positioners,\n                        electrical and fibre connections, and future magnet integration without redesigning\n                        the experimental platform.<br/>• Ultra-high vacuum (UHV): Our experiments run continuously\n                        for several weeks. A vacuum level better than 1 × 10⁻⁹ mbar is essential to avoid\n                        contamination of samples and optical windows, ensuring stable measurement conditions\n                        and reproducible results over long measurement periods.<br/>• Remote cryocooler and\n                        ultra-low vibration: Our experiments rely on interferometric and other vibration-sensitive\n                        optical measurements. The cryocooler must be physically separated from the optical\n                        table to minimise vibration and acoustic noise transmission, while maintaining the\n                        flexibility to move the cryostat when experimental configurations evolve.<br/>• Extensive\n                        optical access: Four side windows and one top window are required to provide simultaneous\n                        laser excitation, imaging, collection optics, and future experimental configurations\n                        that cannot be accommodated by standard cryostat designs.<br/>• Future magnet integration:\n                        The system must support straightforward integration of a 4-1-1 vector magnet and allow\n                        different magnet configurations to be installed or removed without major modifications\n                        to the cryostat.<br/><br/>3. Why There Is Only One Supplier<br/>The selected supplier\n                        is the only identified manufacturer capable of providing all required features within\n                        one validated and integrated platform.<br/>In particular, the supplier uniquely combines:<br/>•\n                        A Ø250 mm × 250 mm cryogenic sample space.<br/>• UHV performance (&lt;10⁻⁹ mbar) suitable\n                        for multi-week experiments.<br/>• A remote cryocooler architecture delivering very\n                        low vibration while preserving cryostat mobility.<br/>• Unobstructed 360° optical\n                        access with multiple optical ports.<br/>• Integrated high-current, RF, fibre-optic,\n                        and DC measurement infrastructure.<br/>• A design specifically prepared for future\n                        vector magnet integration and compatibility with different magnet configurations.<br/>•\n                        Cryogenic positioners and cryostat supplied by the same manufacturer, ensuring full\n                        mechanical, thermal, electrical, and software compatibility while eliminating integration\n                        risks.<br/><br/>Although alternative suppliers may offer some individual features,\n                        no other supplier was found that can simultaneously provide the required UHV performance,\n                        large sample volume, remote low-vibration architecture, extensive optical access,\n                        future magnet flexibility, and fully integrated cryogenic positioning system. We have\n                        nonetheless ensured that the terms of acquisition reflect sound financial judgment\n                        and serve the best interests of SDU and Danish taxpayers. Based on the market coverage,\n                        there is only one supplier who can deliver the desired equipment.<br/></span></section>\n                  <section><span class=\"label\">Category of award weight criterion</span><span class=\"text\">: </span><span class=\"dynamic-label\">Weight (points, exact)</span><section><span class=\"label\">Award criterion number</span><span class=\"text\">: </span><span class=\"value\">100</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>5.1.15&nbsp;<span class=\"label\">Techniques</span><section><span class=\"label\">Framework agreement</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">No framework agreement</span></section>\n               </section>\n               <section><span class=\"label\">Information about the dynamic purchasing system</span><span class=\"text\">:</span><section><span class=\"dynamic-label\">No dynamic purchase system</span></section>\n               </section>\n            </section>\n            <section>5.1.16&nbsp;<span class=\"label\">Further information, mediation and review</span><section><span class=\"label\">Review organisation</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Information about review deadlines</span><span class=\"text\">: </span><span class=\"value\">I henhold til lov om Klagenævnet for Udbud gælder følgende frist for indgivelse af\n                     klage:<br/>Klage over ikke at være blevet prækvalificeret skal være indgivet til Klagenævnet\n                     for Udbud inden 20 kalenderdage fra dagen efter afsendelse af en underretning til\n                     de berørte ansøgere om, hvem der er blevet udvalgt, jf. udbudslovens § 171, stk. 2,\n                     eller klagenævnslovens § 2, stk. 1, nr. 1, når underretningen er ledsaget af en begrundelse\n                     for beslutningen.<br/>I andre situationer skal klage over udbud være indgivet til\n                     Klagenævnet for Udbud inden:<br/><br/>1) 45 kalenderdage efter, at ordregiveren har\n                     offentliggjort en bekendtgørelse i Den Europæiske Unions Tidende om, at ordregiveren\n                     har indgået en kontrakt. Fristen regnes fra dagen efter den dag, hvor bekendtgørelsen\n                     er blevet offentliggjort.<br/>2) 30 kalenderdage regnet fra dagen efter den dag, hvor\n                     ordregiveren har underrettet de berørte tilbudsgivere om, at en kontrakt baseret på\n                     en rammeaftale med genåbning af konkurrencen eller et dynamisk indkøbssystem er indgået,\n                     hvis underretningen har angivet en begrundelse for beslutningen.<br/>3) seks måneder\n                     efter, at ordregiveren har indgået en rammeaftale, regnet fra dagen efter den dag,\n                     hvor ordregiveren har underrettet de berørte ansøgere og tilbudsgivere, jf. klagenævnslovens\n                     § 2, stk. 2, eller udbudslovens § 171, stk. 4.<br/>4) 20 kalenderdage regnet fra dagen\n                     efter, at ordregiveren har meddelt sin beslutning, jf. udbudslovens § 185, stk. 2.<br/><br/>Senest\n                     samtidig med at en klage indgives til Klagenævnet for Udbud, skal klageren skriftligt\n                     underrette ordregiveren om, at en klage indgives til Klagenævnet for Udbud, og om,\n                     hvorvidt klagen er indgivet i standstill-perioden, jf. klagenævnslovens § 6, stk.\n                     4. I tilfælde, hvor klagen ikke er indgivet i standstill-perioden, skal klageren tillige\n                     angive, hvorvidt der begæres opsættende virkning af klagen, jf. klagenævnslovens §\n                     12, stk. 1.</span></section>\n               <section><span class=\"label\">Organisation providing additional information about the procurement procedure</span><span class=\"text\">: </span><span class=\"value\">Syddansk Universitet</span><span class=\"value\"></span></section>\n               <section><span class=\"label\">Organisation providing more information on the review procedures</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span><span class=\"value\"></span></section>\n            </section>\n         </section>\n      </section>\n      <section>6&nbsp;<span class=\"label\">Results</span><section><span class=\"label\">Value of all contracts awarded in this notice</span><span class=\"text\">: </span><span class=\"value\">3.319.273</span><span class=\"text\"> </span><span class=\"label\">Danish krone</span></section>\n         <section><span class=\"label\">Direct award</span><span class=\"text\">:</span><section><span class=\"label\">Justification for direct award</span><span class=\"text\">: </span><span class=\"dynamic-label\">The contract can be provided only by a particular economic operator because of an absence of competition for technical reasons</span></section>\n            <section><span class=\"label\">Other justification</span><span class=\"text\">: </span><span class=\"value\">The requested cryogenic system must meet a unique combination of optical, cryogenic,\n                  vacuum, vibration, electrical, and future upgrade requirements that are essential\n                  for our research. Following a market assessment, only the proposed supplier was identified\n                  as capable of providing a fully integrated system meeting all mandatory specifications.<br/>1.\n                  Product Specifications Required<br/>The system must provide:<br/>• At least four lateral\n                  optical accesses and one top optical access.<br/>• A large cryogenic sample volume\n                  of Ø250 mm cold plate × 250 mm height.<br/>• Non-magnetic radiation shield with four\n                  horizontal and one vertical optical window.<br/>• Three integrated 50 A high-current\n                  channels to the 4 K stage.<br/>• Four thermally anchored coaxial lines for measurements\n                  up to 20 GHz.<br/>• Four fibre-optic feedthroughs.<br/>• 48 DC electrical connections\n                  at the 4 K cold plate.<br/>• Base temperature ≤ 3.5 K with stability better than 50\n                  mK.<br/>• Cooling power of at least 250 mW at 4.2 K.<br/>• Vibration levels below\n                  30 nm peak-to-peak.<br/>• Ultra-high vacuum better than 1 × 10⁻⁹ mbar.<br/>• Remote\n                  cryocooler architecture with unrestricted 360° optical access.<br/>• Future compatibility\n                  with a removable 4-1-1 vector magnet.<br/>• Complete mobility of the cryostat on the\n                  optical table.<br/><br/>2. Why These Specifications Are Necessary<br/>• Large 250\n                  mm sample space: Required to accommodate complex optical setups, cryogenic positioners,\n                  electrical and fibre connections, and future magnet integration without redesigning\n                  the experimental platform.<br/>• Ultra-high vacuum (UHV): Our experiments run continuously\n                  for several weeks. A vacuum level better than 1 × 10⁻⁹ mbar is essential to avoid\n                  contamination of samples and optical windows, ensuring stable measurement conditions\n                  and reproducible results over long measurement periods.<br/>• Remote cryocooler and\n                  ultra-low vibration: Our experiments rely on interferometric and other vibration-sensitive\n                  optical measurements. The cryocooler must be physically separated from the optical\n                  table to minimise vibration and acoustic noise transmission, while maintaining the\n                  flexibility to move the cryostat when experimental configurations evolve.<br/>• Extensive\n                  optical access: Four side windows and one top window are required to provide simultaneous\n                  laser excitation, imaging, collection optics, and future experimental configurations\n                  that cannot be accommodated by standard cryostat designs.<br/><br/>• Future magnet\n                  integration: The system must support straightforward integration of a 4-1-1 vector\n                  magnet and allow different magnet configurations to be installed or removed without\n                  major modifications to the cryostat.<br/>3. Why There Is Only One Supplier<br/>The\n                  selected supplier is the only identified manufacturer capable of providing all required\n                  features within one validated and integrated platform.<br/>In particular, the supplier\n                  uniquely combines:<br/>• A Ø250 mm × 250 mm cryogenic sample space.<br/>• UHV performance\n                  (&lt;10⁻⁹ mbar) suitable for multi-week experiments.<br/>• A remote cryocooler architecture\n                  delivering very low vibration while preserving cryostat mobility.<br/>• Unobstructed\n                  360° optical access with multiple optical ports.<br/>• Integrated high-current, RF,\n                  fibre-optic, and DC measurement infrastructure.<br/>• A design specifically prepared\n                  for future vector magnet integration and compatibility with different magnet configurations.<br/>•\n                  Cryogenic positioners and cryostat supplied by the same manufacturer, ensuring full\n                  mechanical, thermal, electrical, and software compatibility while eliminating integration\n                  risks.<br/><br/>Although alternative suppliers may offer some individual features,\n                  no other supplier was found that can simultaneously provide the required UHV performance,\n                  large sample volume, remote low-vibration architecture, extensive optical access,\n                  future magnet flexibility, and fully integrated cryogenic positioning system. We have\n                  nonetheless ensured that the terms of acquisition reflect sound financial judgment\n                  and serve the best interests of SDU and Danish taxpayers. Based on the market coverage,\n                  there is only one supplier who can deliver the desired equipment.<br/></span></section>\n         </section>\n         <section>6.1&nbsp;<span class=\"label\">Result lot identifier</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span><section><span class=\"dynamic-label\">At least one winner was chosen.</span></section>\n            <section>6.1.2&nbsp;<span class=\"label\">Information about winners</span><section><span class=\"label\">Winner</span><span class=\"text\">:</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Qnity SAS</span></section>\n                  <section><span class=\"label\">Tender</span><span class=\"text\">:</span></section>\n                  <section><span class=\"label\">Tender identifier</span><span class=\"text\">: </span><span class=\"value\">132295</span></section>\n                  <section><span class=\"label\">Identifier of lot or group of lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n                  <section><span class=\"label\">Value of the tender</span><span class=\"text\">: </span><span class=\"value\">3.319.273</span><span class=\"text\"> </span><span class=\"dynamic-label\">Danish krone</span></section>\n                  <section><span class=\"label\">Subcontracting</span><span class=\"text\">: </span><span class=\"dynamic-label\">No</span></section>\n                  <section><span class=\"label\">Contract information</span><span class=\"text\">:</span><section><span class=\"label\">Identifier of the contract</span><span class=\"text\">: </span><span class=\"value\">132295</span></section>\n                     <section><span class=\"label\">Title</span><span class=\"text\">: </span><span class=\"value\">Low vibration, high vacuum cryostat, with vector magnet for SDU / Qnity SAS</span></section>\n                     <section><span class=\"label\">Date on which the winner was chosen</span><span class=\"text\">: </span><span class=\"value\">11-08-2026</span></section>\n                     <section><span class=\"label\">Date of the conclusion of the contract</span><span class=\"text\">: </span><span class=\"value\">07-09-2026</span></section>\n                  </section>\n               </section>\n            </section>\n            <section>6.1.4&nbsp;<span class=\"label\">Statistical information</span><section><span class=\"label\">Received tenders or requests to participate</span><span class=\"text\">:</span><section><span class=\"label\">Type of received submissions</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tenders</span><section><span class=\"label\">Number of tenders or requests to participate received</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n                  <section><span class=\"label\">Type of received submissions</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tenders from micro, small or medium tenderers</span><section><span class=\"label\">Number of tenders or requests to participate received</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n                  <section><span class=\"label\">Type of received submissions</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tenders from tenders registered in countries outside of the European Economic Area</span><section><span class=\"label\">Number of tenders or requests to participate received</span><span class=\"text\">: </span><span class=\"value\">0</span></section>\n                  </section>\n                  <section><span class=\"label\">Type of received submissions</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tenders submitted electronically</span><section><span class=\"label\">Number of tenders or requests to participate received</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n                  <section><span class=\"label\">Type of received submissions</span><span class=\"text\">: </span><span class=\"dynamic-label\">Tenders from tenderers registered in other European Economic Area countries than the country of the buyer</span><section><span class=\"label\">Number of tenders or requests to participate received</span><span class=\"text\">: </span><span class=\"value\">1</span></section>\n                  </section>\n               </section>\n            </section>\n         </section>\n      </section>\n      <section>8&nbsp;<span class=\"label\">Organisations</span><section>8.1&nbsp;<span class=\"value\">ORG-0001</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Syddansk Universitet</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">29283958</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Campusvej 55</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Odense M</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">5230</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Contact point</span><span class=\"text\">: </span><span class=\"value\">Christina From-Nielsen</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">cfro@sdu.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">65509484</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.sdu.dk/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Buyer</span></section>\n               <section><span class=\"label\">Organisation providing additional information about the procurement procedure</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-1000</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Comdia ApS</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">33501404</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Lindvedvej 71</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Odense S</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">5260</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Fyn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK031</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">support@comdia.com</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 7199 3672</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.comdia.com/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">TED eSender</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-1001</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Klagenævnet for Udbud</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">37795526</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Nævnenes Hus, Toldboden 2</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Viborg</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">8800</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Vestjylland</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK041</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">klfu@naevneneshus.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 7240 5600</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">http://www.klfu.dk</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Review organisation</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-1002</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Konkurrence- og Forbrugerstyrelsen</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">10294819</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">Carl Jacobsens Vej 35</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">Valby</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">2500</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Københavns omegn</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">DK012</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">Denmark</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">kfst@kfst.dk</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+45 4171 5000</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://www.kfst.dk/</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Organisation providing more information on the review procedures</span></section>\n            </section>\n         </section>\n         <section>8.1&nbsp;<span class=\"value\">ORG-0002</span><section><span class=\"label\">Official name</span><span class=\"text\">: </span><span class=\"value\">Qnity SAS</span></section>\n            <section><span class=\"label\">Size of the economic operator</span><span class=\"text\">: </span><span class=\"label\">Medium</span></section>\n            <section><span class=\"label\">Registration number</span><span class=\"text\">: </span><span class=\"value\">FR15939451985</span></section>\n            <section><span class=\"label\">Postal address</span><span class=\"text\">: </span><span class=\"value\">42 BIS RUE THEODORE DE BANVILLE</span><span class=\"text\"> </span><span class=\"value\"></span><span class=\"text\"> </span><span class=\"value\"></span></section>\n            <section><span class=\"label\">Town</span><span class=\"text\">: </span><span class=\"value\">PALAISEAU</span></section>\n            <section><span class=\"label\">Postcode</span><span class=\"text\">: </span><span class=\"value\">91120</span></section>\n            <section><span class=\"label\">Country subdivision (NUTS)</span><span class=\"text\">: </span><span class=\"dynamic-label\">Essonne</span><span class=\"text\"> </span><span class=\"text\">(</span><span class=\"value\">FR104</span><span class=\"text\">)</span></section>\n            <section><span class=\"label\">Country</span><span class=\"text\">: </span><span class=\"dynamic-label\">France</span></section>\n            <section><span class=\"label\">Email</span><span class=\"text\">: </span><span class=\"value\">caby@qnity.io</span></section>\n            <section><span class=\"label\">Telephone</span><span class=\"text\">: </span><span class=\"value\">+33667770474</span></section>\n            <section><span class=\"label\">Internet address</span><span class=\"text\">: </span><span class=\"value\">https://qnity.io</span></section>\n            <section><span class=\"label\">Roles of this organisation</span><span class=\"text\">:</span><section><span class=\"label\">Tenderer</span></section>\n               <section><span class=\"label\">Winner of these lots</span><span class=\"text\">: </span><span class=\"value\">LOT-0000</span></section>\n            </section>\n         </section>\n      </section>\n      <section><span class=\"label\">Notice information</span><section><span class=\"label\">Notice identifier/version</span><span class=\"text\">: </span><span class=\"value\">048492d6-e305-46b0-879a-c9be10911af9</span><span class=\"text\"> </span><span class=\"text\">- </span><span class=\"value\">01</span></section>\n         <section><span class=\"label\">Form type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Result</span></section>\n         <section><span class=\"label\">Notice type</span><span class=\"text\">: </span><span class=\"dynamic-label\">Contract or concession award notice – standard regime</span></section>\n         <section><span class=\"label\">Notice dispatch date</span><span class=\"text\">: </span><span class=\"value\">07-09-2026</span><span class=\"text\"> </span><span class=\"value\">13:49 +02:00</span></section>\n         <section><span class=\"label\">Languages in which this notice is officially available</span><span class=\"text\">: </span><span class=\"dynamic-label\">Danish</span><span class=\"text\"> </span><span class=\"dynamic-label\"></span></section>\n         <section><span class=\"label\">Notice publication number</span><span class=\"text\">: </span><span class=\"value\">00616391-2026</span></section>\n         <section><span class=\"label\">OJ S issue number</span><span class=\"text\">: </span><span class=\"value\">173/2026</span></section>\n         <section><span class=\"label\">Publication date</span><span class=\"text\">: </span><span class=\"value\">08-09-2026</span></section>\n      </section>\n   </body>\n</html>","opsummeringDA":{"card":{"titel":"Low vibration, high vacuum cryostat, with vector magnet for SDU","ordregiver":"Syddansk Universitet","ordregiverId":"29283958","ordregiverIdDatavasket":"29283958","publiceringsdato":"2026-09-08+02:00","cpvKode":"38970000","cpvTitel":"Simulatorer til forskning, prøvning eller teknisk-videnskabelig brug","formulartype":"Resultater","formulartypeKode":"result","tidsfrister":[],"alleOrdregivere":["Syddansk Universitet"],"beskrivelse":"The requested cryogenic system must meet a unique combination of optical, cryogenic, vacuum, vibration, electrical, and future upgrade requirements that are essential for our research. Following a market assessment, only the proposed supplier was identified as capable of providing a fully integrated system meeting all mandatory specifications.\n\n1. Product Specifications Required\n\nThe system must provide:\n\n•At least four lateral optical accesses and one top optical access.\n\n•A large cryogenic sample volume of Ø250 mm cold plate × 250 mm height.\n\n•Non-magnetic radiation shield with four horizontal and one vertical optical window.\n\n•Three integrated 50 A high-current channels to the 4 K stage.\n\n•Four thermally anchored coaxial lines for measurements up to 20 GHz.\n\n•Four fibre-optic feedthroughs.\n\n•48 DC electrical connections at the 4 K cold plate.\n\n•Base temperature ≤ 3.5 K with stability better than 50 mK.\n\n•Cooling power of at least 250 mW at 4.2 K.\n\n•Vibration levels below 30 nm peak-to-peak.\n\n•Ultra-high vacuum better than 1 × 10⁻⁹ mbar.\n\n•Remote cryocooler architecture with unrestricted 360° optical access.\n\n•Future compatibility with a removable 4-1-1 vector magnet.\n\n•Complete mobility of the cryostat on the optical table.\n\n2. Why These Specifications Are Necessary\n\n•Large 250 mm sample space: Required to accommodate complex optical setups, cryogenic positioners, electrical and fibre connections, and future magnet integration without redesigning the experimental platform.\n\n•Ultra-high vacuum (UHV): Our experiments run continuously for several weeks. A vacuum level better than 1 × 10⁻⁹ mbar is essential to avoid contamination of samples and optical windows, ensuring stable measurement conditions and reproducible results over long measurement periods.\n\n•Remote cryocooler and ultra-low vibration: Our experiments rely on interferometric and other vibration-sensitive optical measurements. The cryocooler must be physically separated from the optical table to minimise vibration and acoustic noise transmission, while maintaining the flexibility to move the cryostat when experimental configurations evolve.\n\n•Extensive optical access: Four side windows and one top window are required to provide simultaneous laser excitation, imaging, collection optics, and future experimental configurations that cannot be accommodated by standard cryostat designs.\n\n•Future magnet integration: The system must support straightforward integration of a 4-1-1 vector magnet and allow different magnet configurations to be installed or removed without major modifications to the cryostat.\n\n3. Why There Is Only One Supplier\n\nThe selected supplier is the only identified manufacturer capable of providing all required features within one validated and integrated platform.\n\nIn particular, the supplier uniquely combines:\n\n•A Ø250 mm × 250 mm cryogenic sample space.\n\n•UHV performance (<10⁻⁹ mbar) suitable for multi-week experiments.\n\n•A remote cryocooler architecture delivering very low vibration while preserving cryostat mobility.\n\n•Unobstructed 360° optical access with multiple optical ports.\n\n•Integrated high-current, RF, fibre-optic, and DC measurement infrastructure.\n\n•A design specifically prepared for future vector magnet integration and compatibility with different magnet configurations.\n\n•Cryogenic positioners and cryostat supplied by the same manufacturer, ensuring full mechanical, thermal, electrical, and software compatibility while eliminating integration risks.\n\nAlthough alternative suppliers may offer some individual features, no other supplier was found that can simultaneously provide the required UHV performance, large sample volume, remote low-vibration architecture, extensive optical access, future magnet flexibility, and fully integrated cryogenic positioning system. We have nonetheless ensured that the terms of acquisition reflect sound financial judgment and serve the best interests of SDU and Danish taxpayers. Based on the market coverage, there is only one supplier who can deliver the desired equipment.","bkSubTypeKode":"29","bkSubType":"Bekendtgørelse om indgåede kontrakter – det generelle direktiv, standardordningen","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":["DK031"],"udforelsesstedSubLand":["Fyn"],"udforelsesstedLand":["Danmark"],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]},"opsummeringEN":{"card":{"titel":"Low vibration, high vacuum cryostat, with vector magnet for SDU","ordregiver":"Syddansk Universitet","ordregiverId":"29283958","ordregiverIdDatavasket":"29283958","publiceringsdato":"2026-09-08+02:00","cpvKode":"38970000","cpvTitel":"Research, testing and scientific technical simulator","formulartype":"Result","formulartypeKode":"result","tidsfrister":[],"alleOrdregivere":["Syddansk Universitet"],"beskrivelse":"The requested cryogenic system must meet a unique combination of optical, cryogenic, vacuum, vibration, electrical, and future upgrade requirements that are essential for our research. Following a market assessment, only the proposed supplier was identified as capable of providing a fully integrated system meeting all mandatory specifications.\n\n1. Product Specifications Required\n\nThe system must provide:\n\n•At least four lateral optical accesses and one top optical access.\n\n•A large cryogenic sample volume of Ø250 mm cold plate × 250 mm height.\n\n•Non-magnetic radiation shield with four horizontal and one vertical optical window.\n\n•Three integrated 50 A high-current channels to the 4 K stage.\n\n•Four thermally anchored coaxial lines for measurements up to 20 GHz.\n\n•Four fibre-optic feedthroughs.\n\n•48 DC electrical connections at the 4 K cold plate.\n\n•Base temperature ≤ 3.5 K with stability better than 50 mK.\n\n•Cooling power of at least 250 mW at 4.2 K.\n\n•Vibration levels below 30 nm peak-to-peak.\n\n•Ultra-high vacuum better than 1 × 10⁻⁹ mbar.\n\n•Remote cryocooler architecture with unrestricted 360° optical access.\n\n•Future compatibility with a removable 4-1-1 vector magnet.\n\n•Complete mobility of the cryostat on the optical table.\n\n2. Why These Specifications Are Necessary\n\n•Large 250 mm sample space: Required to accommodate complex optical setups, cryogenic positioners, electrical and fibre connections, and future magnet integration without redesigning the experimental platform.\n\n•Ultra-high vacuum (UHV): Our experiments run continuously for several weeks. A vacuum level better than 1 × 10⁻⁹ mbar is essential to avoid contamination of samples and optical windows, ensuring stable measurement conditions and reproducible results over long measurement periods.\n\n•Remote cryocooler and ultra-low vibration: Our experiments rely on interferometric and other vibration-sensitive optical measurements. The cryocooler must be physically separated from the optical table to minimise vibration and acoustic noise transmission, while maintaining the flexibility to move the cryostat when experimental configurations evolve.\n\n•Extensive optical access: Four side windows and one top window are required to provide simultaneous laser excitation, imaging, collection optics, and future experimental configurations that cannot be accommodated by standard cryostat designs.\n\n•Future magnet integration: The system must support straightforward integration of a 4-1-1 vector magnet and allow different magnet configurations to be installed or removed without major modifications to the cryostat.\n\n3. Why There Is Only One Supplier\n\nThe selected supplier is the only identified manufacturer capable of providing all required features within one validated and integrated platform.\n\nIn particular, the supplier uniquely combines:\n\n•A Ø250 mm × 250 mm cryogenic sample space.\n\n•UHV performance (<10⁻⁹ mbar) suitable for multi-week experiments.\n\n•A remote cryocooler architecture delivering very low vibration while preserving cryostat mobility.\n\n•Unobstructed 360° optical access with multiple optical ports.\n\n•Integrated high-current, RF, fibre-optic, and DC measurement infrastructure.\n\n•A design specifically prepared for future vector magnet integration and compatibility with different magnet configurations.\n\n•Cryogenic positioners and cryostat supplied by the same manufacturer, ensuring full mechanical, thermal, electrical, and software compatibility while eliminating integration risks.\n\nAlthough alternative suppliers may offer some individual features, no other supplier was found that can simultaneously provide the required UHV performance, large sample volume, remote low-vibration architecture, extensive optical access, future magnet flexibility, and fully integrated cryogenic positioning system. We have nonetheless ensured that the terms of acquisition reflect sound financial judgment and serve the best interests of SDU and Danish taxpayers. Based on the market coverage, there is only one supplier who can deliver the desired equipment.","bkSubTypeKode":"29","bkSubType":"Contract award notice – general directive, standard regime","erAendring":false},"indholdsType":"HENTET_FRA_TED","sekundaereOrdregivere":[],"udforelsesstedNutsCode":["DK031"],"udforelsesstedSubLand":["Fyn"],"udforelsesstedLand":["Denmark"],"udforelsesstedBy":[],"tilbudsfrister":[],"intressentfrister":[],"deltagelsefrister":[],"svarfrister":[],"antalParts":0,"antalLots":1,"udbudsDokumenter":[]}}